2085-IF8 is a 8-channel analog input module in the Micro800 expansion line. Eight 14-bit channels on one slot: this is the card for a skid with a full complement of transmitters, where four channels would leave the panel short.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
| 2085-IA8 | 8-point 120 V AC input | IN STOCK |
| 2085-IM8 | 8-point 240 V AC input | IN STOCK |
| 2085-OA8 | 8-point 120/240 V AC triac output | IN STOCK |
| 2085-IQ32T | 32-point 12/24 V DC sink/source input | IN STOCK |
| 2085-OV16 | 16-point 12/24 V DC sink transistor output | IN STOCK |
| 2085-OB16 | 16-point 12/24 V DC source transistor output | IN STOCK |
| 2085-OW8 | 8-point AC/DC relay output | IN STOCK |
| 2085-OW16 | 16-point AC/DC relay output, 2 A | IN STOCK |
| 2085-IF4 | 4-channel 14-bit isolated analog input | IN STOCK |
| 2085-IF8 | 8-channel 14-bit isolated analog input | IN STOCK |
| 2085-OF4 | 4-channel 12-bit isolated analog output | IN STOCK |
| 2085-IRT4 | 4-channel 16-bit RTD and thermocouple input | IN STOCK |
| 2085-ECR | 2085 expansion bus terminator | IN STOCK |
Catalog number |
2085-IF8 |
Product type |
8-channel analog input module |
Points / channels |
8 channels |
Signal |
0-20 mA, 4-20 mA (default), -10 to +10 V DC |
Isolation |
Isolated, field wiring to controller |
Backplane current, 5 V DC |
Not published |
Dimensions, H x W x D |
Not published |
Temperature rating |
Not published |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Terminal block |
Removable terminal block (RTB) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM003 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2085-IF8 is a 8-channel analog input module in the Micro800 expansion line. Eight 14-bit channels on one slot: this is the card for a skid with a full complement of transmitters, where four channels would leave the panel short.
It mounts to the right of a Micro810, Micro820, Micro830, Micro850 or Micro870 controller and is addressed by its position in the expansion chain, so the slot order in the project has to match the physical order.
Signal and channel count are fixed by the catalog number: 8 channels, 0-20 mA, 4-20 mA (default), -10 to +10 V DC.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
Same isolation rule as the 4-channel card: field to controller, not channel to channel.
Size the conductors and the torque to the module data sheet; the RTB screws are hand-tightened, not driven with a power tool.
Module order matters: the expansion chain is scanned in physical order, and the bus is ended with a terminator. Range per channel is set in software, and the default is 4-20 mA.
Backplane draw is Not published. Add every module in the chain before deciding on the controller power budget.
Rockwell lists this catalog number as Active.
Dimensions are Not published and the rated ambient is Not published.
UPC is Not published, country of origin Not published.
Check that the module comes with its RTB. A module sold without the terminal block is not a drop-in swap, whatever the price difference.
Confirm the catalog number against the project: the 2085 line separates sink from source transistor outputs and AC input from DC input by catalog number only.
Check the sensor loop supply before ordering: a 2-wire transmitter needs the loop powered from the panel, which the module does not do.
What does 2085-IF8 do?
8-channel analog input module: 8 channels, 0-20 mA, 4-20 mA (default), -10 to +10 V DC.
Where does 2085-IF8 mount?
To the right of a Micro800 controller, in the expansion chain, connected through the 2085 bus.
How much backplane current does 2085-IF8 draw?
Not published.
What are the dimensions of 2085-IF8?
Not published, rated Not published.
Is 2085-IF8 a current Rockwell product?
Rockwell lists it as Active.
2085-IF8 is a 8 channel isolated analog input expansion module in the Micro800 system, and the analog specification rows below are the published values for this catalog number, including the drift and overload rows that are usually omitted.
| Specification | Value |
|---|---|
| Catalog number | 2085-IF8, 8 channel 14 bit isolated voltage and current input expansion module |
| Number of inputs | 8, isolated |
| Resolution | 14 bits, 13 bits plus sign; 1.28 mV per count unipolar and bipolar on voltage, 1.28 microamps per count on current |
| Data format | Left justified, 16 bit twos complement |
| Update rate | Under 2 ms per enabled channel without 50/60 Hz rejection; under 8 ms for all channels; 8 ms with 50/60 Hz rejection |
| Step response to 63 percent | 4 to 60 ms without rejection, depending on the number of enabled channels and the filter setting; 600 ms with rejection |
| Input ranges, current | 4 to 20 mA default, 0 to 20 mA, both user configurable |
| Input ranges, voltage | Plus or minus 10V, 0 to 10V, both user configurable |
| Input impedance | Over 1 MOhm on the voltage terminal; under 100 Ohm on the current terminal |
| Absolute accuracy | Plus or minus 0.10 percent of full scale at 25 degrees C |
| Accuracy drift with temperature | 0.00428 percent of full scale per degree C on voltage; 0.00407 percent per degree C on current |
| Calibration | Factory calibrated, no customer calibration supported |
| Overload | 30V continuous or 32 mA continuous on one channel at a time |
| Bus current draw | 110 mA at 5V DC and 50 mA at 24V DC, maximum |
| Variant | 2085-IF8K is the conformally coated version |
| Source | 2080-TD001 Micro800 technical data, analog input expansion I/O specifications |
Eight isolated channels on one module with the same per channel update as the four channel version, and the difference appears only in the bus current: one hundred and ten milliamps against one hundred. That is a cheap way to double the channel count in the same rail width.
Fifty and sixty hertz rejection raises the settled response from tens of milliseconds to six hundred, which is why it is a per channel decision. A panel that enables rejection globally for noise and then wonders why the level loop is slow has made one decision twice.
Resolution, accuracy, drift and update rate are kept separate on this page because they answer different questions. Where the source publishes a range that depends on the filter setting or the enabled channel count, the range is reproduced rather than collapsed to one number.
Current loops are the default for a reason. Four to twenty milliamps survives voltage drop on a long cable and it has a live zero, so a broken wire reads as an under-range value rather than as zero percent of the process, and that difference is what lets the program detect a fault.
Factory calibration with no customer calibration supported is a statement about the service model. The module is replaced rather than trimmed, and a spare belongs on the shelf if the process cannot wait for a shipment.
Data format matters at the programming boundary. Left justified sixteen bit twos complement means the raw value occupies the high bits and the low bits are padding, and a scaling block that assumes right justification produces a value sixteen times too small.
Input impedance separates the two terminals completely. A voltage input above one megaohm barely loads the source, while a current input below one hundred ohms is the burden resistor, and connecting a four to twenty milliamp transmitter to the voltage terminal is a wiring error that reads as a saturated value.
The resistive load window on a milliamp output is the voltage budget of the loop. Fifteen to five hundred ohms at twenty four volts means the loop can carry a reasonable field impedance, and a device outside that window needs a different output or an interposing converter.
An analog channel is specified by four numbers that have to agree with each other: the resolution, the absolute accuracy, the drift with temperature and the update rate. A design that quotes only the resolution is quoting the smallest step the converter can produce, not the accuracy of the value it produces.
Fifty and sixty hertz rejection is the filter that decides how fast the channel can be. Enabling the rejection raises the settled response from a few milliseconds to hundreds, which is a fine trade for a temperature or a level, and an impossible one for a torque loop.
A plug-in analog module is a compromise on isolation and on channel count, and it is priced accordingly. Four non-isolated unipolar channels in a controller slot solve a small machine, and the same four channels in an isolated expansion module solve a panel with several supplies.
Bipolar and unipolar ranges change the resolution arithmetic. A twelve bit unipolar converter divides its span into four thousand and ninety six steps, and the same converter configured bipolar divides the same span into two thousand and forty eight steps on each side, which halves the step size claim.
Output channels hold zero until they are configured. A drive reference or a valve positioner that sees zero on a download is a safe behaviour, and a program that assumes the previous value is retained will be wrong after every power cycle.
Sensor type coverage on a temperature module is a list, not a guarantee of accuracy. The published accuracy range spans the whole list, so the actual error for one thermocouple type has to be read from the type specific table rather than from the headline.
Overload tolerance is a commissioning feature. Thirty volts or thirty two milliamps continuous on one channel at a time is what protects the module from a miswired transmitter during a loop check, and it is also a warning that the protection is per channel rather than per module.
Accuracy figures published at twenty five degrees are laboratory figures. The drift per degree is what the panel actually sees, and a cabinet that runs twenty degrees above ambient multiplies the drift into a real error that belongs in the loop calculation.
Use it to double channel count in the same width, and keep the rejection decision per channel rather than global.
The Allen-Bradley Micro and Nano systems category groups the other catalog numbers, options and spare parts in the same range.