Product Details:
Payment & Shipping Terms:
|
2085-ECR is a Expansion bus terminator in the Micro800 expansion line. The terminator closes the 2085 expansion bus at the end of the chain. Without it the last module in a chain is not electrically terminated, and the symptoms are intermittent, not obvious.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
| 2085-IA8 | 8-point 120 V AC input | IN STOCK |
| 2085-IM8 | 8-point 240 V AC input | IN STOCK |
| 2085-OA8 | 8-point 120/240 V AC triac output | IN STOCK |
| 2085-IQ32T | 32-point 12/24 V DC sink/source input | IN STOCK |
| 2085-OV16 | 16-point 12/24 V DC sink transistor output | IN STOCK |
| 2085-OB16 | 16-point 12/24 V DC source transistor output | IN STOCK |
| 2085-OW8 | 8-point AC/DC relay output | IN STOCK |
| 2085-OW16 | 16-point AC/DC relay output, 2 A | IN STOCK |
| 2085-IF4 | 4-channel 14-bit isolated analog input | IN STOCK |
| 2085-IF8 | 8-channel 14-bit isolated analog input | IN STOCK |
| 2085-OF4 | 4-channel 12-bit isolated analog output | IN STOCK |
| 2085-IRT4 | 4-channel 16-bit RTD and thermocouple input | IN STOCK |
| 2085-ECR | 2085 expansion bus terminator | IN STOCK |
Catalog number |
2085-ECR |
Product type |
Expansion bus terminator |
Points / channels |
Not applicable |
Signal |
Bus termination, no field signal |
Isolation |
Not applicable |
Backplane current, 5 V DC |
Not applicable |
Dimensions, H x W x D |
Per 2085 line |
Temperature rating |
Per 2085 line |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Terminal block |
Removable terminal block (RTB) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM003 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2085-ECR is a Expansion bus terminator in the Micro800 expansion line. The terminator closes the 2085 expansion bus at the end of the chain. Without it the last module in a chain is not electrically terminated, and the symptoms are intermittent, not obvious.
It mounts to the right of a Micro810, Micro820, Micro830, Micro850 or Micro870 controller and is addressed by its position in the expansion chain, so the slot order in the project has to match the physical order.
Signal and channel count are fixed by the catalog number: Not applicable, Bus termination, no field signal.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
It carries no field wiring: it plugs onto the bus connector of the last module in the chain.
Size the conductors and the torque to the module data sheet; the RTB screws are hand-tightened, not driven with a power tool.
Module order matters: the expansion chain is scanned in physical order, and the bus is ended with a terminator. It is the cheapest part in the chain and the one most often missing from a second-hand controller bundle.
Backplane draw is Not applicable. Add every module in the chain before deciding on the controller power budget.
Rockwell lists this catalog number as Active.
Dimensions are Per 2085 line and the rated ambient is Per 2085 line.
UPC is Not published, country of origin Not published.
Check that the module comes with its RTB. A module sold without the terminal block is not a drop-in swap, whatever the price difference.
Confirm the catalog number against the project: the 2085 line separates sink from source transistor outputs and AC input from DC input by catalog number only.
When a chain is extended by one module, the terminator has to move to the new last module.
What does 2085-ECR do?
Expansion bus terminator: Not applicable, Bus termination, no field signal.
Where does 2085-ECR mount?
To the right of a Micro800 controller, in the expansion chain, connected through the 2085 bus.
How much backplane current does 2085-ECR draw?
Not applicable.
What are the dimensions of 2085-ECR?
Per 2085 line, rated Per 2085 line.
Is 2085-ECR a current Rockwell product?
Rockwell lists it as Active.