The 2080-LC50-48QWB is the DC-input 48-point Micro850 with twenty relay outputs and six embedded high-speed counters.
Relays keep the AC load list inside the controller while the inputs stay on 24 V sensors.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC50-48QWB |
Family |
Micro850 expandable Ethernet controller |
I/O points |
48 (28 inputs, 20 relay outputs) |
Inputs |
28 inputs, 24 V DC sink/source (standard and high-speed) |
Outputs |
20 relay outputs, 2 A at 240 V AC and 1 A at 24 V DC |
Supply |
24 V DC Class 2, 21.4 to 26.4 V DC |
Communication |
USB 2.0 Type B, 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial |
Plug-in modules |
3 slots (24-point) or 5 slots (48-point), plus up to four expansion I/O modules |
Dimensions, H x W x D |
90 x 238 x 80 mm |
Shipping weight |
0.725 kg |
Temperature rating |
-20 to 65 C (-4 to 149 F) |
Power consumption, max |
11 W without plug-ins and expansion, 33 W with |
Lifecycle |
Rockwell literature 2080-TD001 lists the 2080-L50E successor for this point count; the LC50 catalog number itself does not appear in the current revision |
Output terminals |
Relay |
Ethernet nodes |
8 |
Expansion I/O |
Up to four 2085 modules |
Remote LCD |
2080-REMLCD supported from firmware 23.011 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-TD001 (module specifications) and 2080-UM002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC50-48QWB is the DC-input 48-point Micro850 with twenty relay outputs and six embedded high-speed counters.
Relays keep the AC load list inside the controller while the inputs stay on 24 V sensors.
Five plug-in slots and four expansion modules make it the largest general-purpose configuration in the family.
Relay output rating is 2 A at 240 V AC and 1 A at 24 V DC per point.
Inputs are 24 V DC sink/source, standard and high-speed.
Six embedded high-speed counters are listed for the 48-point chassis.
Communication and capacity. USB 2.0 Type B, 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial
3 slots (24-point) or 5 slots (48-point), plus up to four expansion I/O modules plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 90 x 238 x 80 mm, shipping 0.725 kg.
Rated ambient -20 to 65 C (-4 to 149 F), maximum consumption 11 W without plug-ins and expansion, 33 W with.
Lifecycle. Rockwell literature 2080-TD001 lists the 2080-L50E successor for this point count; the LC50 catalog number itself does not appear in the current revision
Five plug-in slots, four expansion modules, eight Ethernet nodes.
Rockwell's technical data lists the 2080-L50E-480WB successor for this point count.
Supply is 24 V DC Class 2, 21.4 to 26.4 V DC.
How many I/O points does 2080-LC50-48QWB have?
Micro850 expandable Ethernet controller: 48 (28 inputs, 20 relay outputs).
What is the input type on 2080-LC50-48QWB?
28 inputs, 24 V DC sink/source (standard and high-speed).
What does 2080-LC50-48QWB use for communication?
USB 2.0 Type B, 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial.
What are the dimensions of 2080-LC50-48QWB?
90 x 238 x 80 mm, 0.725 kg.
What is the lifecycle status of 2080-LC50-48QWB?
Rockwell literature 2080-TD001 lists the 2080-L50E successor for this point count; the LC50 catalog number itself does not appear in the current revision.
2080-LC50-48QWB is a 48 point Micro850 controller with DC inputs and relay outputs, and the ratings below are the published 48 point Micro850 figures for the point count, the supply, the input current and the output switching capability of that model.
| Specification | Value |
|---|---|
| Catalog number | 2080-LC50-48QWB, Micro850 48 point controller, 24V DC input, relay output |
| Input circuit type | 24V DC sink or source, standard and high-speed, 8.8 mA per point, 28 inputs |
| Output circuit type | Relay, 2 A at 240V AC and 1 A at 24V DC, 20 outputs |
| Number of I/O | 48, arranged as 28 inputs and 20 outputs |
| Dimensions | 90 x 238 x 80 mm, 3.54 x 9.37 x 3.15 in |
| Shipping weight | Approximately 0.725 kg, 1.60 lb |
| Power supply voltage range | 21.4 to 26.4V DC, Class 2 |
| Power consumption | 11 W without plug-in modules and expansion I/O; 33 W with plug-in modules and expansion I/O |
| Wire size | 0.2 square millimetres, 24 AWG, to 2.5 square millimetres, 14 AWG, rated 90 degrees C insulation maximum |
| Terminal screw torque | 0.4 to 0.5 N·m, 3.5 to 4.4 lb in, with a 0.6 x 3.5 mm screwdriver |
| Wiring category | Category 2 on signal ports, power ports and communication ports |
| Expansion capacity | Up to four expansion I/O modules from the 2085 family |
| Communication | USB 2.0, 10/100 Base-T Ethernet, RS-232/RS-485 non-isolated combo serial, DF1 protocol modes supported |
| Source | 2080-TD001 Micro800 programmable controllers technical data, Micro850 48 point general specifications |
| Published catalog prefix | Electrical figures published under the 2080-L50E-48xxx catalogs; confirm the LC50 prefix on the nameplate |
Relay outputs on a 48 point controller are the right choice for a machine with mixed load types: a lamp, a solenoid and a small motor can all sit on the same module. The alternative is a sink or source model where every output shares one switching convention.
The eight point eight milliamp input current makes these inputs usable with standard three wire sensors, and the inputs accept sink or source sensors, which is a wiring choice rather than an ordering choice on this model.
The general specifications, the I/O rating and the derating figures on this page are the published Micro850 48 point data. Where the technical data publishes the electrical figures under a different catalog prefix, the table says which, instead of silently substituting.
Expansion capacity is a hard number, not a suggestion. Micro850 controllers accept up to four expansion modules, and the 2085 family is the one that fits them, while the 2080 plug-in modules occupy the two plug-in slots on the compact models. Mixing the two kinds of expansion is a common ordering error.
Firmware revision gates features on these controllers. EtherNet/IP Class 1 connections to drives and remote LCD support arrive at specific revisions, and a controller from stock may predate them, so the revision belongs in the commissioning checklist rather than in the brochure.
Power supply choice follows from the input type, not from the output type. A controller with 120 to 240 volt AC inputs takes its field power from the same source that feeds the inputs, while a 24 volt DC input model needs a separate supply and puts that supply on the bill of materials.
The microSD slot is a maintenance feature more than a data feature. Project backup and restore from a card is what allows a service technician to replace a controller without a laptop and the original project file, and data logging and recipes are the secondary uses.
Conformal coating suffixes exist across the family for the same reason they exist elsewhere: condensing humidity, corrosive atmospheres and washdown areas. The suffix changes the materials, not the point mix, and the electrical ratings stay with the base catalog number.
Analog channels shared with digital inputs are a compromise worth understanding. Four 24 volt DC inputs can be configured as 0 to 10 volt analog inputs on the DC input models, which means the channel count is shared rather than added, and a machine that needs both cannot have both.
Plug-in modules and expansion modules are different form factors with different buses. A plug-in module sits in a slot inside the controller housing and shares its power, while an expansion module is a separate DIN rail device with its own terminal blocks, and the wiring effort differs accordingly.
The 2080 numbering carries the point mix in the suffix. AC input models are A, DC input models are Q, and the last letters describe the outputs: W for relay, V for sink, B for source. Reading the suffix is faster than opening the selection guide, and it is the same logic the family uses for expansion modules.
Communication ports on a small controller decide the architecture as much as the I/O does. An embedded Ethernet port with four Class 1 nodes is enough for a drive and a panel, and a serial port with Modbus RTU is enough for a weigh scale, but a machine that needs both protocols on multiple devices has outgrown the compact model.
A twelve point controller with relay outputs is a smart relay replacement, and the design intent is visible in the function blocks: delay on and off, time of day, time of week and time of year are built in rather than programmed, which is what a lighting or pump alternation panel needs.
Rated outputs are the reason these controllers exist in machine building. Two eight amp and two four amp relay outputs on the smallest model remove the external interposing relays for a small pump or a lamp, and the eight amp figure is per output with a total module limit that has to be read before the loads are added up.
The remote LCD module is a configuration aid, not an operator interface. It sets an IP address and shows a text display for a compact controller that has no screen, and its IP65 rating is the reason it can be mounted on the outside of an enclosure rather than behind the door.
A Micro800 controller is specified by the point mix rather than by the point count. Two catalogs with twenty points can carry eight AC inputs and seven relays, or twelve DC inputs and seven relays with an analog output, and the drawing that assumed the wrong mix has to be redone at the terminal level.
Use it for the mixed load types that relays handle, and keep the cabinet temperature inside the range where the ratings hold.
This part sits in the Allen-Bradley Micro and Nano systems category, with the other models and spare parts listed alongside it.