Allen Bradley PLC 1756-OW16I / 1756OW16I

China Allen Bradley PLC 1756-OW16I / 1756OW16I supplier
Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier Allen Bradley PLC 1756-OW16I / 1756OW16I supplier

Large Image :  Allen Bradley PLC 1756-OW16I / 1756OW16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OW16I / 1756OW16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $345.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 20 PCS
Detailed Product Description

1756-OW16I technical data PDF download 1756-OW16I / 1756OW16I Isolated Relay Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OW16I (also written 1756OW16I) is the ControlLogix isolated relay output module: sixteen normally-open contacts, each individually isolated at 250 V basic insulation, carrying pilot duty C300/R150. It is the module for loads that are neither purely AC nor purely DC, and for circuits where a solid-state output would leak too much to switch off.

The contact rating is the number that decides the application, and it is not a single figure: 1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC, 1.5 A at 120 V AC and 0.75 A at 240 V AC. Backplane draw is 150 mA at both 5.1 V and 24 V, 4.4 W total, with 4.5 W maximum dissipation and 15.35 BTU/hr thermal.

1756-OW16I
16 N.O. isolated relay outputs, C300/R150 pilot duty
In stock
1756-OX8I
8 N.O. + 8 N.C. isolated relay outputs, C300/R150
In stock
1756-OB16I
16 DC outputs, solid state, isolated
In stock
1756-OA16I
16 AC outputs, individually isolated
In stock
1756-TBCH
Removable terminal block, 36 terminals
In stock

 Application
 Relay output, isolated contacts
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OW16I
 Type
 Digital relay output module
 Sub Brand
 ControlLogix
 Mounting
 1756 ControlLogix chassis
 Number Of Channels
 16 N.O.
 Output Type
 NO or NO/NC, individually isolated
 Contact Rating
 1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC
 AC Rating
 1.5 A at 120 V AC, 0.75 A at 240 V AC
 Pilot Duty
 C300/R150
 Backplane Current
 150 mA at 5.1 V DC, 150 mA at 24 V DC
 Power Dissipation
 4.5 W max
 Thermal Dissipation
 15.35 BTU/hr
 Isolation Voltage
 250 V (continuous), basic insulation
 Terminal Block
 1756-TBCH or 1756-TBS6H
 Operating Temperature
 0…60 °C (32…140 °F)
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OW16I relay output module product photograph 1756-OW16I, second view product photograph 1756-OW16I, third view product photograph

Where the relay module sits in a typical system

Relay outputs survive in panels because they do not leak, they do not need a load-side supply of the module's own voltage, and they can switch a 24 V DC coil and a 240 V AC contactor from the same module. That is why the OW16I turns up in mixed-voltage machines long after solid-state modules became cheaper.

The individually isolated contacts are the other reason. Sixteen separate pairs let a panel keep a 120 V AC control circuit and a 24 V DC interlock in one card without a common return, which is exactly the sort of mixed cabinet that a commoned solid-state module cannot serve.

The cost of that flexibility is mechanical life. A relay has a finite number of operations, and the published figure for the eight-point variant — 300,000 into a resistive load, 100,000 into an inductive one — is the planning number for any application that cycles more than a few times a minute.

Commissioning in five checks

  1. Check the load current against the contact rating at the actual voltage: 1 A down to 30 V DC but only 0.22 A at 125 V DC, and 0.75 A at 240 V AC. A relay contact does not carry its nameplate current across the whole range.
  2. Respect the minimum load. The OX8I publishes 10 mA per point; below that, the contact may not wet and the circuit reads open when it is closed.
  3. Keep the switching rate inside the published limit — 0.3 Hz at rated load on the OX8I — because a relay has a mechanical life, published as 300,000 operations into a resistive load and 100,000 into an inductive one.
  4. Wire the isolation where the drawing puts it. These are individually isolated contacts at 250 V basic insulation; sharing a common return defeats the reason for buying an isolated module.
  5. Plan replacement before the contacts wear out. A relay output module is a mechanical part in an electronic chassis, and the failure appears as a contact that sticks rather than a module that dies.

Contacts, ratings and the limits that matter

A relay module has no interesting diagnostics: the contact is either made or it is not, and the published limits below are what decide whether it stays that way.

 Indicator  State  Meaning and first action
 OUT 0…15  Off  Contact open; check the load current is at or above the module minimum.
 OK  Green  Module is operating normally.
 OK  Red  Module fault; replace it rather than troubleshooting the contact in place.
 Load  Below rating  Reduce the switched current until it sits inside the published curve for the operating voltage.

Contact ratings, backplane figures and environmental limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a relay output module at end of contact life

The usual failure is a welded or high-resistance contact, not a dead module, and it shows up as an output that will not drop out. Swapping the module is the right first move; troubleshooting a contact in an installed chassis wastes a shift.

Before replacing a failed unit, count the cycles the application actually runs. If the duty is high, the replacement will fail the same way, and the correct fix is a solid-state DC or AC module with a relay only for the pilot duty channels.

Keep the terminal block and its wiring arm: the 1756-TBCH or 1756-TBS6H carries the field wiring, and the replacement module drops into it.

Which relay output module to specify

  • 1756-OW16I — 16 normally-open, individually isolated relay contacts, dry-circuit to 240 V AC.
  • 1756-OX8I — 8 normally-open plus 8 normally-closed isolated contacts, two points per group.
  • 1756-OB16I — the DC solid-state equivalent where relay life is the limiting factor.
  • 1756-OA16I — individually isolated AC solid-state outputs.
  • 1756-TBCH / 1756-TBS6H — the removable terminal blocks both relay modules use.

FAQ — 1756-OW16I / 1756OW16I Isolated Relay Output Module

What is the 1756-OW16I?

A ControlLogix relay output module with 16 normally-open, individually isolated contacts.

What current can each contact carry?

1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC, 1.5 A at 120 V AC and 0.75 A at 240 V AC.

What is its pilot duty rating?

C300/R150.

What does it draw from the backplane?

150 mA at 5.1 V DC and 150 mA at 24 V DC, 4.4 W total, with 4.5 W maximum dissipation.

What isolation does it provide?

250 V continuous, basic insulation, contacts to backplane and contact to contact.

Which terminal block does it use?

1756-TBCH or 1756-TBS6H, user-keyed.

What is the output delay?

10 ms maximum off-to-on and on-to-off.

What are the environmental limits?

0…60 °C operating, -40…85 °C storage, 5…95% relative humidity non-condensing, 30 g shock.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - technical specifications, environmental specifications and certifications for 1756-OW16I and the manufacturer's product page for 1756-OW16I. Values re-checked 16 November 2026.