Product Details:
Payment & Shipping Terms:
|
The 1756-L7SP / 1756L7SP is the GuardLogix 5570 safety controller built on the 5570 hardware: — MB of standard user memory with a separate configured to match the primary controller MB safety memory, one chassis slot, the 1 GB SD card in the slot, and the paired safety partner that turns a standard controller into a SIL 3 / PLe pair.
Published figures for the GuardLogix 5570 controllers are 0.98 MB I/O memory, 128,000 digital I/O maximum, 1756-ESMCAP energy storage module shipped installed, 800 mA at 5.1 V DC and 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, 30 V continuous basic isolation from the USB port to the system, and a shipping weight of 0.25 kg (0.55 lb) (1756-TD001). The safety partner uses its own energy storage module — 1756-SPESMNSE or 1756-SPESMNRM — which is a separate line on the same specification table.
| 1756-L71 | ControlLogix 5570 controller, 2 MB user memory | IN STOCK |
| 1756-L72 | ControlLogix 5570 controller, 4 MB user memory | IN STOCK |
| 1756-L73 | ControlLogix 5570 controller, 8 MB user memory | IN STOCK |
| 1756-L71S | GuardLogix 5570 safety controller, 2 MB / 1 MB safety | IN STOCK |
| 1756-L72S | GuardLogix 5570 safety controller, 4 MB / 2 MB safety | IN STOCK |
| 1756-L73S | GuardLogix 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SP | GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S | IN STOCK |
| 1756-L73XT | ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C | IN STOCK |
| 1756-L73SXT | GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SPXT | GuardLogix-XT 5570 safety partner, pairs with L73SXT | IN STOCK |
Application |
Safety Programmable Logic Controller |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-L7SP |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-L7SP |
Mounting |
Chassis |
Number Of Channels |
1756-L7SP |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Controller |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.
The partner is the least understood part of a GuardLogix order and the most common short-shipment. It is a real module in a real slot, it has its own energy storage and its own diagnostics, and the certified assembly does not exist without it.
In a retrofit the partner is where the slot budget is checked: adding safety to an existing rack means two adjacent slots, the partner's own module, and the safety I/O on the same network as the pair.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| RUN | Steady green | Controller is in Run mode. |
| FORCE | Off | No tags contain I/O force values, or forces are disabled. |
| FORCE | Steady yellow | I/O forces are enabled. A field wiring check made now is not valid. |
| FORCE | Flashing yellow | Forced addresses exist but forces are not enabled; enabling them applies every stored force at once. |
| OK | Off | No power applied to the controller. |
| OK | Flashing red | New controller that needs a firmware update, or a major fault on a controller in service. |
| OK | Steady red | Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable. |
| OK | Steady green | Controller operating normally. |
| Status display | TEST / PASS | Power-up tests running, then completed. |
| Status display | CHRG | Capacitor energy storage module charging; do not remove the ESM. |
| Status display | BUSY | I/O modules in the project are not yet fully powered. |
| Status display | No Project | Controller memory is empty; download the project or load it from the SD card. |
| Status display | Rev XX.xxx | Firmware major and minor revision currently installed. |
Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.
When a 5560 GuardLogix rack is migrated, the partner moves with the controller: 1756-L7SP with an L71S/L72S/L73S, 1756-L7SPXT with the XT controllers. The safety I/O and the chassis stay in place.
The pair is always ordered together. Availability of one without the other is a stopped safety zone, not a partial delivery.
What is the 1756-L7SP?
It is the safety partner of the GuardLogix 5570 pair. It carries no independent user memory — its configuration is set to match the primary controller — and it is ordered as a separate catalogue number occupying its own chassis slot.
Which controllers does it pair with?
1756-L71S, L72S and L73S. The XT partner for the XT controllers is 1756-L7SPXT.
What energy storage does the partner use?
Its own module, 1756-SPESMNSE (removable, no residual wall-clock backup) or 1756-SPESMNRM (non-removable, blocks USB and card removal). The controller's 1756-ESMCAP does not serve the partner.
Why does the pair need two slots?
The architecture is redundant by design: primary controller and partner execute and cross-check the safety task, which is what allows a SIL 3 / PLe claim. One slot cannot hold both functions.
What current does the partner add?
The GuardLogix 5570 table publishes 800 mA at 5.1 V DC and 5 mA at 1.2 V DC for the pair's controllers; the chassis budget is planned for both devices, so the two slots together are the load.
What is the safety task language?
Ladder Diagram only for the safety task; the standard tasks in the primary controller accept Ladder, Structured Text, Function Block Diagram and SFC.
What happens if the partner is missing?
The pair is incomplete and the safety function is not available. A GuardLogix controller without its partner is not a SIL-rated assembly, whatever the program says.
What weight does it ship at?
0.25 kg (0.55 lb) is the published weight for the GuardLogix 5570 controllers; the partner ships as its own item with its own energy storage module.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L7SP. Values re-checked 16 November 2026.