logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-BATA / 1756BATA

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-BATA / 1756BATA

China Allen Bradley PLC 1756-BATA / 1756BATA supplier
Allen Bradley PLC 1756-BATA / 1756BATA supplier Allen Bradley PLC 1756-BATA / 1756BATA supplier Allen Bradley PLC 1756-BATA / 1756BATA supplier Allen Bradley PLC 1756-BATA / 1756BATA supplier Allen Bradley PLC 1756-BATA / 1756BATA supplier Allen Bradley PLC 1756-BATA / 1756BATA supplier

Large Image :  Allen Bradley PLC 1756-BATA / 1756BATA

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-BATA / 1756BATA

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $65.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-BATA technical data PDF download 1756-BATA Replacement Battery Assembly for 1756-BATM | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-BATA (also written 1756BATA) is the replacement battery assembly for the 1756-BATM ControlLogix battery module — Rockwell describes it in exactly those terms: Replacement Battery Assembly For 1756-BATM.

It is a two-part arrangement that catches people out. The module (1756-BATM) is the part that mounts and connects; the battery inside it (1756-BATA) is the consumable. Replacing the battery means ordering the assembly, not the module, once the module is already installed.

Lifecycle is published as End of Life: discontinued 31 December 2027, no planned Rockwell replacement. The module it serves was discontinued earlier, on 18 July 2017, which makes the assembly a support part for an installed base rather than a current design choice.

Published attributes: Series A, UPC 612598284757, function replacement battery backup, temperature rating 0...60 °C (32...140 °F), country of origin Korea (Republic of), one year standard warranty, cutsheet 1756-TD002 and selection guide 1756-SG001.

1756-BA2
Lithium battery assembly, Series B 1756-L6x only, end of life 2027-12-31, UPC 612598322152
Limited stock
1756-BATA
Replacement battery assembly for 1756-BATM, end of life 2027-12-31, UPC 612598284757
Limited stock
1756-BATM
Battery module, 20 mA max at 3.6 V DC, discontinued 2017-07-18, UPC 612598284764
Limited stock

 Application
 Controller battery backup
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-BATA
 Communication
 —
 Display
 —
 Enclosure
 —
 Interface
 Controller battery connector
 Mounting
 Inside controller / module
 Number Of Channels
 —
 Standard
 CE, UL
 Sub Brand
 ControlLogix
 Type
 Battery
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN576 (battery module installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-BATA replacement battery assembly product photograph 1756-BATA battery pack product photograph 1756-BATA assembly view product photograph

Where the module sits in a typical system

For a plant running a 1756-BATM module, the assembly is the only consumable in the backup chain, so its availability is the practical limit on how long the controller keeps its backup through an outage.

Because both the module and the assembly are discontinued, the useful question is not 'where can I buy one' but 'how many outages will this installed base see before the controllers are replaced'. That quantity is the last buy.

Holding one assembly per rack with a BATM module is cheap relative to the consequence: a controller that loses backup during an extended outage is a restart and a program reload, not a battery change.

Commissioning in five steps

  1. Read the series letter on the controller label first. The 1756-BA2 title states 'L6X Ser B ONLY', so a Series A controller is a different battery — the wrong assembly either will not fit or will not be recognised.
  2. Replace the battery with the chassis de-energised and the controller powered down by the documented procedure, so the controller is not left relying on a battery that has just been removed.
  3. Dispose of the removed lithium assembly through the battery waste route. It is a lithium cell, not general electronic waste.
  4. Record the replacement date on the panel schedule. The assemblies carry a shelf life, so a spare kept in a stores bin for years is not the same as a spare bought for this outage.
  5. Because all three catalogue numbers are end-of-life or discontinued, check the current stock position before promising a delivery date to a customer.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Both halves are discontinued The module ended on 18 July 2017; the assembly ends on 31 December 2027, with no planned replacement for either. Stock position, not catalogue listing, decides delivery.
 Check 3 Consumable behaviour The battery is the wear item. Long outages, high cabinet temperature and long storage all shorten usable life, and the temperature rating of 0...60 °C is an operating limit, not a life guarantee.
 Check 4 Origin Country of origin Korea (Republic of) as published — relevant where a customs document has to state it.
 Check 5 Disposal A lithium assembly. It goes through the battery waste route, not general electronic waste.

Lifecycle dates and attributes per the Rockwell product record for this catalogue number; battery data per 1756-TD001 / 1756-TD002 and installation instructions 1756-IN576 and 1756-IN050.

Replacing a 1756-BATA

No planned Rockwell replacement exists for this assembly, and none for the 1756-BATM module it fits. Migration goes through the controller and its backup arrangement, which is a project decision.

The assembly is not interchangeable with 1756-BA2, which is the Series B 1756-L6x battery — different module, different part.

If the module is still healthy but the assembly is not available, the honest options are a last buy from channel stock or a controller migration; substituting another family's battery is not one of them.

Which ControlLogix EtherNet/IP module to specify

  • 1756-BA2 — lithium battery assembly titled 'ControlLogix L6X Ser B ONLY'; fits Series B 1756-L6x controllers, end of life with a 31 December 2027 discontinued date.
  • 1756-BATA — replacement battery assembly for the 1756-BATM module; same end-of-life date, no planned replacement.
  • 1756-BATM — ControlLogix battery module, discontinued 18 July 2017, output 20 mA max at 3.6 V DC, installation instructions 1756-IN576.
  • 1756-TD001 — controller technical data, the cutsheet for the L6x battery assembly.
  • 1756-TD002 — battery cutsheet listed against the 1756-BATA replacement assembly.
  • 1756-SG001 — selection guide; use it to confirm which battery a given controller series takes.

FAQ — 1756-BATA Replacement Battery Assembly for 1756-BATM | Rockwell

What is the 1756-BATA?

The replacement battery assembly for the 1756-BATM ControlLogix battery module, as titled by Rockwell.

Does it replace the module?

No. It is the battery assembly that fits into the module; the module itself is a separate catalogue number, 1756-BATM.

Is it still available?

Published as End of Life with a discontinued date of 31 December 2027 and no planned replacement. Availability before then depends on channel stock.

What is the temperature rating?

0...60 °C (32...140 °F) as published.

Where is it made?

Country of origin Korea (Republic of), UPC 612598284757.

Can I use 1756-BA2 instead?

No — 1756-BA2 is the Series B 1756-L6x battery assembly. The two serve different modules and are not interchangeable.

What should I hold in spares?

One assembly per rail with a BATM module, sized against the number of outages the installed controllers will still see.

How is it disposed of?

As a lithium battery through the battery waste route; it is not general electronic waste.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-BATA. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)