Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier Allen Bradley PLC 1756-L73 / 1756L73 supplier

Large Image :  Allen Bradley PLC 1756-L73 / 1756L73

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L73 / 1756L73

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $5748.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-L73 technical data PDF download ControlLogix 1756-L73 / 1756L73 8 MB Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L73 (also written 1756L73) is the 8 MB controller of the ControlLogix 5570 range and the size most 5570 racks are built around: one chassis slot, a 1 GB SD card installed, the 1756-ESMCAP energy storage module in place of a battery, and a four-character display that reports the firmware revision at power-up.

Its published specification is 8 MB of user memory, 0.98 MB of I/O memory, maximums of 128,000 digital, 4,000 analogue and 128,000 total I/O points, 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, and 30 V continuous basic isolation from the USB port to the system (1756-TD001). The energy storage module is listed as interchangeable between the standard and conformal-coated (K) versions of the controller.

1756-L71 ControlLogix 5570 controller, 2 MB user memory IN STOCK
1756-L72 ControlLogix 5570 controller, 4 MB user memory IN STOCK
1756-L73 ControlLogix 5570 controller, 8 MB user memory IN STOCK
1756-L71S GuardLogix 5570 safety controller, 2 MB / 1 MB safety IN STOCK
1756-L72S GuardLogix 5570 safety controller, 4 MB / 2 MB safety IN STOCK
1756-L73S GuardLogix 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SP GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S IN STOCK
1756-L73XT ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C IN STOCK
1756-L73SXT GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SPXT GuardLogix-XT 5570 safety partner, pairs with L73SXT IN STOCK

 Application
 Programmable Logic Controller
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L73
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-L73
 Mounting
 Chassis
 Number Of Channels
 1756-L73
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L73 controller product photograph 1756-L73 controller, second view product photograph 1756-L73 controller label product photograph

Where the module sits in a typical system

8 MB is the memory size that carries a whole line without splitting it: station programs, the safety-adjacent interlocks, integrated motion over EtherNet/IP, recipe and product data held in the controller, plus the edit headroom that every commissioning consumes.

Because the electrical figures are unchanged across the 5570 family, an L73 upgrade from an L71 or L72 is a controller swap and a download — the chassis supply, the slot width and the isolation rating stay exactly where they were.

Commissioning in five steps

  1. Confirm the chassis supply budget before insertion: every 5570 controller draws 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC, so a rack that was planned around a 5560 controller has headroom, and a rack planned tight does not.
  2. Read the four-character status display at power-up before touching anything: TEST then PASS is a completed self-test, CHRG is the capacitor energy storage module charging, and any message other than PASS belongs in the fault log, not in a re-seat.
  3. The controller ships with a 1756-ESMCAP energy storage module already installed and with a 1 GB 1784-SD1 card in the slot. Both are removable, and a controller that will be shipped or stored needs the residual energy question answered before the ESM comes out.
  4. Load the project only after the firmware revision matches the project, then check the SD indicator: a LOAD or UPDT message means the card is being read at power-up and the card must stay in until the display clears.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 RUN  Steady green  Controller is in Run mode.
 FORCE  Off  No tags contain I/O force values, or forces are disabled.
 FORCE  Steady yellow  I/O forces are enabled. A field wiring check made now is not valid.
 FORCE  Flashing yellow  Forced addresses exist but forces are not enabled; enabling them applies every stored force at once.
 OK  Off  No power applied to the controller.
 OK  Flashing red  New controller that needs a firmware update, or a major fault on a controller in service.
 OK  Steady red  Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable.
 OK  Steady green  Controller operating normally.
 Status display  TEST / PASS  Power-up tests running, then completed.
 Status display  CHRG  Capacitor energy storage module charging; do not remove the ESM.
 Status display  BUSY  I/O modules in the project are not yet fully powered.
 Status display  No Project  Controller memory is empty; download the project or load it from the SD card.
 Status display  Rev XX.xxx  Firmware major and minor revision currently installed.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

For a 5560 rack, the L73 is the functional replacement at the memory size of an L63, with the 5570 programming path, the SD card and the status display. The I/O modules and the chassis do not change.

Above it the 5580 controllers add embedded Ethernet, CIP Security and packet rates measured in tens of thousands per second; within the 5570 range the L74 and L75 cover 16 MB and 32 MB with the same electrical specification.

Which ControlLogix 5570 controller to specify

  • 1756-L71 — 2 MB. Entry point of the 5570 range; the memory size that fits a single machine or a small line with no motion.
  • 1756-L72 — 4 MB. The usual minimum for a line controller with an HMI, produced/consumed tags and some recipe data.
  • 1756-L73 — 8 MB. The volume part of the family and the size most 5570 racks are built around.
  • 1756-L71S / L72S / L73S — GuardLogix versions with a separate safety memory (1 / 2 / 4 MB) alongside the standard memory.
  • 1756-L7SP — the safety partner that pairs with a GuardLogix 5570 controller to reach SIL 3 / PLe.
  • 1756-L73XT / L73SXT / L7SPXT — the same controllers and partner in the XT range for -25…+70 °C panels.

FAQ — ControlLogix 1756-L73 / 1756L73 8 MB Controller

What memory does the 1756-L73 have?

8 MB of user memory and 0.98 MB of I/O memory, with maximums of 128,000 digital, 4,000 analogue and 128,000 total I/O points (1756-TD001).

Is the 1756-L73 the same electrically as the L71?

Yes. 800 mA at 5.1 V DC, 5 mA at 1.2 V DC, 2.5 W, 8.5 BTU/hr and 30 V continuous basic isolation from the USB port to the system are printed identically for L71, L72, L73, L74 and L75.

What is the 1756-ESMCAP and why does it ship installed?

It is the removable capacitor energy storage module that replaces the lithium battery in the 5570 controllers; it ships with every standard and conformal-coated 1756-L7 controller. It holds wall-clock time across a power cycle and its charge is shown as CHRG on the status display.

Can the SD card be removed while the controller is running?

Only when no card activity is shown. SAVE, LOAD and UPDT on the status display mean the card is being written or read; the manual requires the save or load to finish before the card is removed or power is disconnected (1756-UM001).

How many tasks and programs can it run?

The 5570 controllers run the Logix task model with a continuous task plus periodic and event tasks, each holding up to 100 programs; the exact count and the instruction execution times are listed in the 5570 controller user manual and the Logix 5000 programming manuals.

What replaces a 1756-L63?

The 1756-L73 is the memory-equivalent move in the 5570 family: 8 MB against 8 MB, one slot, same chassis. What changes is the programming port, the nonvolatile storage and the firmware revision the project is rebuilt at.

Which indicators does it carry?

Four: RUN, FORCE, SD and OK, plus the four-character status display (1756-UM001). A steady red OK during power-up or ESM discharge is normal; a flashing red OK on a used controller is a major fault.

What surrounds it in the cabinet?

Any 1756 chassis slot, one slot wide, 0…60 °C surrounding air, open-style enclosure, with the 800 mA at 5.1 V DC counted against the chassis supply together with every I/O module in the rack.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L73. Values re-checked 16 November 2026.