logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-TBS6H / 1756TBS6H

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-TBS6H / 1756TBS6H

China Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier
Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier Allen Bradley PLC 1756-TBS6H / 1756TBS6H supplier

Large Image :  Allen Bradley PLC 1756-TBS6H / 1756TBS6H

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-TBS6H / 1756TBS6H

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $46.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-TBS6H technical data PDF download 1756-TBS6H / 1756TBS6H Spring Clamp Terminal Block

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-TBS6H (also written 1756TBS6H) is the spring-clamp terminal block for the same module families that take the 1756-TBCH — 16- and 32-point digital modules and the eight-channel HART analog output. It accepts a single conductor of 0.33…2.1 mm² (22…14 AWG), rated 105 °C, 1.2 mm maximum strip.

It exists for panels that specify spring termination to remove the screw-torque variable from a wiring check.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Removable terminal block for I/O modules
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-TBS6H
 Type
 Spring clamp terminal block
 Sub Brand
 ControlLogix
 Mounting
 Module front, keyed
 Wire Size, Single
 0.33…2.1 mm² (22…14 AWG)
 Wire Insulation
 105 °C (221 °F) or greater
 Insulation Strip
 1.2 mm (3/64 in) maximum
 Connections Per Terminal
 One
 Torque
 Not applicable, spring clamp
 Keying
 User-defined mechanical
 Conformal Version
 1756-TBS6HS

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-TBS6H terminal block product photograph 1756-TBS6H, second view product photograph 1756-TBS6H, third view product photograph

Where the terminal block sits in the panel

Spring termination removes one class of fault and introduces another. There is no torque to verify, but the block publishes a single connection only — two wires cannot share a terminal, so a point that needs a second conductor has to move to the 1756-TBNH.

The published wire range is identical to the TBCH: 0.33…2.1 mm² (22…14 AWG), 105 °C insulation, 1.2 mm maximum strip. Because the range is identical, a cable schedule written for the screw-clamp version can be reused unchanged when the panel switches to spring clamps.

The torque figure published in the module tables belongs to the screw-clamp blocks — 0.5 N·m for TBCH and 1.36 N·m for TBNH. Applying that check to a spring clamp is meaningless, and the practical verification is a pull test on the conductor rather than a torque wrench.

Module pairing is the same as the screw version: the digital 16/32-point families and the HART eight-channel output list TBCH and TBS6H together, while 8-channel analog modules list TBNH and TBSH. The two blocks are alternatives within a module row, not across families.

Keying is user-defined mechanical, set on the block and module pair. A spring block transferred from one module to another carries the old keying with it.

The conformal-coated version is 1756-TBS6HS, published as single connection only, with the same wire range and the same 1756-TBCHS 0.5 N·m screw figure applying to the screw-clamp counterpart rather than to the spring block.

Commissioning in five checks

  1. Match the block to the module family first. Eight-channel analog modules list TBNH and TBSH; the HART eight-channel output lists TBCH and TBS6H. A block that fits the slot physically may still be the wrong block for the module.
  2. Use the published torque for the block in hand, not for the module: TBCH 0.5 N·m (4.4 lb·in), TBNH 1.36 N·m (12 lb·in).
  3. Decide the double-connection question before wiring. Only TBNH accepts two conductors, and only at 0.33…1.3 mm² (22…16 AWG) for the second wire.
  4. Keep the wire at 105 °C rated insulation with a 1.2 mm maximum strip; the terminal is rated for that, and a thicker insulation will not seat.
  5. Do not intermix solid and stranded wire in a double connection, and keep both conductors the same size.

Termination faults that look like module faults

A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.

 Indicator  State  Meaning and first action
 Two wires will not fit  —  Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection.
 Spring terminal will not accept a second wire  —  TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal.
 Fault appears after a module swap  —  RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable.
 Agency mark questioned on a retrofit  —  The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval.

Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a terminal block

A spring terminal that releases a conductor under vibration is usually a strip-length problem; re-check the 1.2 mm maximum and the 105 °C insulation grade before replacing the block.

Spring blocks are single-connection: if a point was doubled up in the old screw block, split the wire before swapping.

Re-key the block to the module before installation.

Which ControlLogix terminal block to specify

  • 1756-TBCH — screw clamp, single connection, 0.5 N·m.
  • 1756-TBS6H — spring clamp, single connection, same wire range.
  • 1756-TBNH — screw clamp with double-connection option, 1.36 N·m.
  • 1756-TBSH — spring clamp, single connection, for 8-channel modules.
  • 1756-TBCHS / TBS6HS / TBNHS / TBSHS — conformal-coated versions for corrosive or condensing locations.

FAQ — 1756-TBS6H / 1756TBS6H Spring Clamp Terminal Block

What is the 1756-TBS6H?

A spring-clamp removable terminal block for ControlLogix I/O modules.

What wire size does it accept?

0.33…2.1 mm² (22…14 AWG), single connection only.

Can two conductors share a terminal?

No — the block is published as single connection only.

How is it different from the 1756-TBCH?

Same wire range and same module families; spring clamp instead of screw clamp, so no torque check.

What insulation rating is needed?

105 °C (221 °F) or greater, with 1.2 mm maximum strip.

Which modules use it?

16- and 32-point digital modules and the 1756-OF8H, alongside the TBCH.

Is there a conformal-coated version?

Yes, 1756-TBS6HS.

Does it need to be torqued?

No — torque figures in the module tables apply to the screw-clamp blocks.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBS6H and the manufacturer's product page for 1756-TBS6H. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)