Product Details:
Payment & Shipping Terms:
|
The 1756-TBS6H (also written 1756TBS6H) is the spring-clamp terminal block for the same module families that take the 1756-TBCH — 16- and 32-point digital modules and the eight-channel HART analog output. It accepts a single conductor of 0.33…2.1 mm² (22…14 AWG), rated 105 °C, 1.2 mm maximum strip.
It exists for panels that specify spring termination to remove the screw-torque variable from a wiring check.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Removable terminal block for I/O modules |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-TBS6H |
Type |
Spring clamp terminal block |
Sub Brand |
ControlLogix |
Mounting |
Module front, keyed |
Wire Size, Single |
0.33…2.1 mm² (22…14 AWG) |
Wire Insulation |
105 °C (221 °F) or greater |
Insulation Strip |
1.2 mm (3/64 in) maximum |
Connections Per Terminal |
One |
Torque |
Not applicable, spring clamp |
Keying |
User-defined mechanical |
Conformal Version |
1756-TBS6HS |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Spring termination removes one class of fault and introduces another. There is no torque to verify, but the block publishes a single connection only — two wires cannot share a terminal, so a point that needs a second conductor has to move to the 1756-TBNH.
The published wire range is identical to the TBCH: 0.33…2.1 mm² (22…14 AWG), 105 °C insulation, 1.2 mm maximum strip. Because the range is identical, a cable schedule written for the screw-clamp version can be reused unchanged when the panel switches to spring clamps.
The torque figure published in the module tables belongs to the screw-clamp blocks — 0.5 N·m for TBCH and 1.36 N·m for TBNH. Applying that check to a spring clamp is meaningless, and the practical verification is a pull test on the conductor rather than a torque wrench.
Module pairing is the same as the screw version: the digital 16/32-point families and the HART eight-channel output list TBCH and TBS6H together, while 8-channel analog modules list TBNH and TBSH. The two blocks are alternatives within a module row, not across families.
Keying is user-defined mechanical, set on the block and module pair. A spring block transferred from one module to another carries the old keying with it.
The conformal-coated version is 1756-TBS6HS, published as single connection only, with the same wire range and the same 1756-TBCHS 0.5 N·m screw figure applying to the screw-clamp counterpart rather than to the spring block.
A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.
| Indicator | State | Meaning and first action |
| Two wires will not fit | — | Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection. |
| Spring terminal will not accept a second wire | — | TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal. |
| Fault appears after a module swap | — | RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable. |
| Agency mark questioned on a retrofit | — | The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval. |
Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.
A spring terminal that releases a conductor under vibration is usually a strip-length problem; re-check the 1.2 mm maximum and the 105 °C insulation grade before replacing the block.
Spring blocks are single-connection: if a point was doubled up in the old screw block, split the wire before swapping.
Re-key the block to the module before installation.
What is the 1756-TBS6H?
A spring-clamp removable terminal block for ControlLogix I/O modules.
What wire size does it accept?
0.33…2.1 mm² (22…14 AWG), single connection only.
Can two conductors share a terminal?
No — the block is published as single connection only.
How is it different from the 1756-TBCH?
Same wire range and same module families; spring clamp instead of screw clamp, so no torque check.
What insulation rating is needed?
105 °C (221 °F) or greater, with 1.2 mm maximum strip.
Which modules use it?
16- and 32-point digital modules and the 1756-OF8H, alongside the TBCH.
Is there a conformal-coated version?
Yes, 1756-TBS6HS.
Does it need to be torqued?
No — torque figures in the module tables apply to the screw-clamp blocks.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBS6H and the manufacturer's product page for 1756-TBS6H. Values re-checked 16 November 2026.