|
Product Details:
Payment & Shipping Terms:
|
The 1756-OB16D (also written 1756OB16D) is the 16-point diagnostic DC output: 19.2...30 V DC, 2 A pilot duty (DC-13/S0) at 30 °C derating to 1 A at 60 °C, UL rating 24 V DC at 2 A, backplane 250 mA at 5.1 V DC and 140 mA at 24 V DC, isolation 250 V basic outputs-to-backplane, 125 V basic group-to-group (1756-IN062).
The 140 mA at 24 V DC is unique in the output table and easy to miss. Every other DC output draws 2 to 3 mA on the 24 V rail; this one draws 140 mA because its diagnostics are powered from that rail. In a chassis with several OB16D modules the 24 V budget is the number to check first.
Diagnostics are the reason to buy it. The module compares each commanded output with the measured state and reports a mismatch, which turns a failed lamp, a broken wire or a welded contact into a reported fault instead of a silent no-action. The minimum load matters here: below the module's MDL the diagnostic cannot resolve the load, and 8 A at 30 °C falling to 4 A at 60 °C is the module total the measurement is built around.
Derating is published per point rather than left to judgement: 2 A at 30 °C, 1 A at 60 °C. A cabinet at 50 °C sits between those two columns and needs the interpolation done deliberately.
1756-IB16 | 16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 | In stock |
1756-IB16D | 16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA | In stock |
1756-IB16I | 16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA | In stock |
1756-IB16IF | 16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA | In stock |
1756-IB16ISOE | 16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA | In stock |
1756-IB32 | 32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 | In stock |
1756-IC16 | 16 inputs, 30...60 V DC, backplane per 1756-IN062 | In stock |
1756-IG16 | 16 TTL inputs, backplane per 1756-IN062 | In stock |
1756-IV16 | 16 inputs, 48 V DC, backplane per 1756-IN062 | In stock |
Application | Discrete output |
Brand Name | Rockwell (Rockwell) |
Cat Num | 1756-OB16D |
Communication | Backplane (producer/consumer) |
Display | — |
Enclosure | None (open-style) |
Interface | Removable terminal block |
Mounting | Chassis slot |
Number Of Channels | 16 |
Standard | CE, UL, CSA, RCM |
Sub Brand | ControlLogix |
Type | Digital Output Module |
UNSPSC | — |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The OB16D suits outputs whose failure must be visible: safety-adjacent indication, valve position feedback paths, and any point where a welded contact or a burned lamp has to be reported rather than discovered later.
It is also the practical 2 A card for panels that need per-point diagnostics without a separate interface module, provided the 140 mA at 24 V DC is counted in the chassis budget.
Where diagnostics are not needed, the OB16I delivers 2 A pilot duty at 350 mA on the 5.1 V rail and 2.5 mA at 24 V, for a fraction of the 24 V draw.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 19.2 V DC minimum | The published lower limit is 19.2 V, not 10 V. A sagging 24 V supply near 19 V is at the edge. |
| Check 3 | 2 A to 1 A derating | 30 °C to 60 °C, linearly. Do not size a 50 °C cabinet from the 2 A column. |
| Check 4 | Group isolation only | 125 V between groups of eight, none within a group. The field returns are shared inside each group. |
| Check 5 | Minimum load for diagnostics | A load below the module's MDL reads as a diagnostic fault, not as a healthy off state. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
For 2 A pilot duty without diagnostics, 1756-OB16I draws 2.5 mA at 24 V DC instead of 140 mA.
For 32 diagnostic-free points at 500 mA, 1756-OB32 covers the density with a 16 A module rating.
For fast switching, 1756-OB16IEF and 1756-OB16IEFS publish 2 A at 45 °C on four channels.
What is the 1756-OB16D?
A 16-point diagnostic DC output, 19.2...30 V DC, 2 A at 30 °C derating to 1 A at 60 °C, with load diagnostics.
Why does it draw so much on the 24 V rail?
140 mA at 24 V DC, because the diagnostic circuits are supplied from that rail.
What isolation does it provide?
250 V basic outputs-to-backplane and 125 V basic between the two output groups, with none inside a group.
What is the module maximum current?
8 A at 30 °C and 4 A at 60 °C.
What is the minimum output voltage?
19.2 V DC — the published lower limit, not 10 V.
Can it report a failed load?
Yes, it compares commanded and measured state per point, provided the load is above the module's minimum load current.
What is its temperature code?
T4A under the North American classification, with 60 °C maximum surrounding air.
Which publication should be quoted?
1756-IN062 for the ratings and 1756-UM058 for configuration and diagnostics.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16D. Values re-checked 15 November 2026.