Allen Bradley PLC 1756-OB16D / 1756OB16D

China Allen Bradley PLC 1756-OB16D / 1756OB16D supplier
Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier Allen Bradley PLC 1756-OB16D / 1756OB16D supplier

Large Image :  Allen Bradley PLC 1756-OB16D / 1756OB16D

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB16D / 1756OB16D

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $445.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-OB16D technical data PDF download 1756-OB16D ControlLogix 16 Point Diagnostic DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB16D (also written 1756OB16D) is the 16-point diagnostic DC output: 19.2...30 V DC, 2 A pilot duty (DC-13/S0) at 30 °C derating to 1 A at 60 °C, UL rating 24 V DC at 2 A, backplane 250 mA at 5.1 V DC and 140 mA at 24 V DC, isolation 250 V basic outputs-to-backplane, 125 V basic group-to-group (1756-IN062).

The 140 mA at 24 V DC is unique in the output table and easy to miss. Every other DC output draws 2 to 3 mA on the 24 V rail; this one draws 140 mA because its diagnostics are powered from that rail. In a chassis with several OB16D modules the 24 V budget is the number to check first.

Diagnostics are the reason to buy it. The module compares each commanded output with the measured state and reports a mismatch, which turns a failed lamp, a broken wire or a welded contact into a reported fault instead of a silent no-action. The minimum load matters here: below the module's MDL the diagnostic cannot resolve the load, and 8 A at 30 °C falling to 4 A at 60 °C is the module total the measurement is built around.

Derating is published per point rather than left to judgement: 2 A at 30 °C, 1 A at 60 °C. A cabinet at 50 °C sits between those two columns and needs the interpolation done deliberately.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB16D
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB16D module product photograph 1756-OB16D label product photograph 1756-OB16D terminal side product photograph

Where the module sits in a typical system

The OB16D suits outputs whose failure must be visible: safety-adjacent indication, valve position feedback paths, and any point where a welded contact or a burned lamp has to be reported rather than discovered later.

It is also the practical 2 A card for panels that need per-point diagnostics without a separate interface module, provided the 140 mA at 24 V DC is counted in the chassis budget.

Where diagnostics are not needed, the OB16I delivers 2 A pilot duty at 350 mA on the 5.1 V rail and 2.5 mA at 24 V, for a fraction of the 24 V draw.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 19.2 V DC minimum The published lower limit is 19.2 V, not 10 V. A sagging 24 V supply near 19 V is at the edge.
 Check 3 2 A to 1 A derating 30 °C to 60 °C, linearly. Do not size a 50 °C cabinet from the 2 A column.
 Check 4 Group isolation only 125 V between groups of eight, none within a group. The field returns are shared inside each group.
 Check 5 Minimum load for diagnostics A load below the module's MDL reads as a diagnostic fault, not as a healthy off state.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 2 A pilot duty without diagnostics, 1756-OB16I draws 2.5 mA at 24 V DC instead of 140 mA.

For 32 diagnostic-free points at 500 mA, 1756-OB32 covers the density with a 16 A module rating.

For fast switching, 1756-OB16IEF and 1756-OB16IEFS publish 2 A at 45 °C on four channels.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB16D ControlLogix 16 Point Diagnostic DC Output | Rockwell

What is the 1756-OB16D?

A 16-point diagnostic DC output, 19.2...30 V DC, 2 A at 30 °C derating to 1 A at 60 °C, with load diagnostics.

Why does it draw so much on the 24 V rail?

140 mA at 24 V DC, because the diagnostic circuits are supplied from that rail.

What isolation does it provide?

250 V basic outputs-to-backplane and 125 V basic between the two output groups, with none inside a group.

What is the module maximum current?

8 A at 30 °C and 4 A at 60 °C.

What is the minimum output voltage?

19.2 V DC — the published lower limit, not 10 V.

Can it report a failed load?

Yes, it compares commanded and measured state per point, provided the load is above the module's minimum load current.

What is its temperature code?

T4A under the North American classification, with 60 °C maximum surrounding air.

Which publication should be quoted?

1756-IN062 for the ratings and 1756-UM058 for configuration and diagnostics.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16D. Values re-checked 15 November 2026.