|
Product Details:
Payment & Shipping Terms:
|
The 1756-IR6I (also written 1756IR6I) is the six-channel isolated RTD input of the first ControlLogix analog generation: six individually isolated RTD channels on a 20-pin removable terminal block, with a published isolation rating of 250 V continuous between channels and to the backplane (Rockwell product record).
Its role in the range was to bring temperature into the rack without a separate temperature transmitter per point: six three-wire RTDs on one module, each isolated, so sensors bonded to different machine frames do not share a common path.
Lifecycle is the fact a buyer needs first: the catalogue number was discontinued on 31 March 2017, and Rockwell classifies the replacement as a functional replacement rather than a direct one. The wiring, the terminal block and the channel count all change when the replacement module is fitted.
Beyond the channel count, the 250 V isolation and the 20-pin terminal block, Rockwell's product record for this catalogue number refers the input signal and sensor ranges to the catalogue, and the current edition of 1756-TD002 no longer prints the consolidated table. We publish here only the values we can cite; ask us for the module-specific table if the design depends on resolution or backplane current. Module behaviour per 1756-UM009.
1756-IF4FXOF2F |
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation |
In stock |
1756-IF6CIS |
6 isolated current inputs with sourcing 24 V DC loop supply |
In stock |
1756-IF6I |
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation |
In stock |
1756-IF8 |
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane |
In stock |
1756-IF8H |
8 differential HART current inputs, A and B series |
In stock |
1756-IF16 |
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth |
In stock |
1756-IF16H |
16 differential HART current inputs, A and B series |
In stock |
1756-IRT8I |
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required |
In stock |
1756-IR6I |
6 isolated RTD inputs, 20-pin block, discontinued 2017 |
In stock |
1756-IT6I |
6 thermocouple inputs, two mV ranges, one CJC sensor |
In stock |
1756-IT6I2 |
6 isolated thermocouple inputs, 16-bit, two CJC sensors |
In stock |
Application |
Analog input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IR6I |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
6 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Analog Input Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IR6I is now a spares and legacy-support item. It appears in panels built before 2017, and the reason to buy one is to keep an existing panel running or to replace a failed module in a plant that has no appetite for re-wiring a working installation.
In that role the isolation is the useful characteristic: six RTDs on separate machine frames, each with its own barrier, in a panel whose drawings already show this module.
For a new installation the module is the wrong starting point. The 1756-IRT8I carries eight isolated channels with 24-bit resolution and published backplane figures, and the 1756-IR12 carries twelve channels for RTDs alone.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | Functional replacement, not drop-in | Rockwell's replacement category is functional: the channel count, wiring and terminal block differ, so a replacement is a re-design of the field wiring. |
| Check 3 | Six isolated channels | Individually isolated, 250 V continuous to the backplane — the reason this module was specified instead of a common-referenced input. |
| Check 4 | 20-pin terminal block | The six channels land on a 20-pin housing, ordered separately. A 36-pin block from another module does not fit. |
| Check 5 | Ranges are in the catalogue | Rockwell's product record refers the input signal to the catalogue for this number; confirm the RTD curve and range against the label of the module in hand. |
Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.
The current isolated temperature module is 1756-IRT8I: 8 isolated channels, RTD and thermocouple, 24-bit, 200 mA at 5.1 V DC on a 1756-A chassis.
For RTDs at higher density, 1756-IR12 provides 12 channels at 24-bit, 200 mA at 5.1 V DC and 70 mA at 24 V DC.
For thermocouples, 1756-IT6I2 and 1756-IT16 cover 6 and 16 channels respectively.
What is the 1756-IR6I?
A 6-channel individually isolated RTD input module for the ControlLogix chassis, on a 20-pin terminal block.
Is it still available?
No. It was discontinued on 31 March 2017, with a functional replacement rather than a drop-in equivalent.
What isolation does it provide?
250 V continuous isolation between channels and to the backplane, per the published product record.
Which terminal block does it use?
A 20-pin removable terminal block, ordered separately.
What is the resolution?
Rockwell's current 1756-TD002 no longer publishes the consolidated table for this number; the input signal is referred to the catalogue. Ask us for the module-specific table.
What replaces it?
1756-IRT8I for 8 isolated RTD or thermocouple channels, or 1756-IR12 for 12 RTD channels.
Can I mix it with newer modules in one chassis?
Yes — it is a standard ControlLogix analog module and occupies one slot, but the terminal block and wiring are specific to this number.
What documents cover it?
1756-UM009 for module behaviour; the installation instructions for the module family are the original analog I/O publication.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IR6I. Values re-checked 15 November 2026.