logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-TBSH / 1756TBSH

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-TBSH / 1756TBSH

China Allen Bradley PLC 1756-TBSH / 1756TBSH supplier
Allen Bradley PLC 1756-TBSH / 1756TBSH supplier Allen Bradley PLC 1756-TBSH / 1756TBSH supplier Allen Bradley PLC 1756-TBSH / 1756TBSH supplier Allen Bradley PLC 1756-TBSH / 1756TBSH supplier Allen Bradley PLC 1756-TBSH / 1756TBSH supplier Allen Bradley PLC 1756-TBSH / 1756TBSH supplier

Large Image :  Allen Bradley PLC 1756-TBSH / 1756TBSH

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-TBSH / 1756TBSH

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $38.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-TBSH technical data PDF download 1756-TBSH / 1756TBSH Spring Clamp Terminal Block, 8-Channel

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-TBSH (also written 1756TBSH) is the spring-clamp block for the 8-channel module family — the analog modules that list TBNH as their screw alternative. One conductor of 0.33…2.1 mm² (22…14 AWG), 105 °C insulation, 1.2 mm maximum strip.

Its published wording is unambiguous: a single wire connection, and no multiple conductors on any terminal.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Removable terminal block for 8-channel modules
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-TBSH
 Type
 Spring clamp terminal block
 Sub Brand
 ControlLogix
 Mounting
 Module front, keyed
 Wire Size, Single
 0.33…2.1 mm² (22…14 AWG)
 Connections Per Terminal
 One, no multiple conductors
 Wire Insulation
 105 °C (221 °F) or greater
 Insulation Strip
 1.2 mm (3/64 in) maximum
 Torque
 Not applicable, spring clamp
 Keying
 User-defined mechanical
 Conformal Version
 1756-TBSHS

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-TBSH terminal block product photograph 1756-TBSH, second view product photograph 1756-TBSH, third view product photograph

Where the terminal block sits in the panel

This block deliberately does not offer the double connection that its screw-clamp twin, the 1756-TBNH, provides. A point that needs a jumper or a shield drain has to be wired as a single conductor here or moved to the TBNH.

The wire range is the same as the TBNH for a single conductor — 0.33…2.1 mm² (22…14 AWG) at 105 °C with 1.2 mm strip — so a schedule can be carried across when a panel changes termination style, as long as no point was doubled up.

Torque does not apply. The 1.36 N·m figure in the module tables belongs to the TBNH screw clamp; on this block the verification is a conductor pull test.

It pairs with the 8-channel analog modules, the same family the TBNH serves. The module row lists both blocks as alternatives, so choosing spring termination does not change the module, the slot or the wiring diagram.

Keying is user-defined mechanical, and the block and module pair is keyed together; a spring block taken from a 16-point module will not be keyed for an analog slot.

The conformal-coated version is 1756-TBSHS, published as single connection only with the same wire range.

Commissioning in five checks

  1. Match the block to the module family first. Eight-channel analog modules list TBNH and TBSH; the HART eight-channel output lists TBCH and TBS6H. A block that fits the slot physically may still be the wrong block for the module.
  2. Use the published torque for the block in hand, not for the module: TBCH 0.5 N·m (4.4 lb·in), TBNH 1.36 N·m (12 lb·in).
  3. Decide the double-connection question before wiring. Only TBNH accepts two conductors, and only at 0.33…1.3 mm² (22…16 AWG) for the second wire.
  4. Keep the wire at 105 °C rated insulation with a 1.2 mm maximum strip; the terminal is rated for that, and a thicker insulation will not seat.
  5. Do not intermix solid and stranded wire in a double connection, and keep both conductors the same size.

Termination faults that look like module faults

A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.

 Indicator  State  Meaning and first action
 Two wires will not fit  —  Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection.
 Spring terminal will not accept a second wire  —  TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal.
 Fault appears after a module swap  —  RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable.
 Agency mark questioned on a retrofit  —  The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval.

Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a terminal block

A conductor that releases under vibration is usually strip length; check the 1.2 mm maximum before replacing the block.

Spring blocks accept one conductor only — a doubled point has to be split or moved to the 1756-TBNH.

Keep the 105 °C insulation grade; a 90 °C wire in a 60 °C ambient panel is close to its limit at the terminal.

Which ControlLogix terminal block to specify

  • 1756-TBCH — screw clamp, single connection, 0.5 N·m.
  • 1756-TBS6H — spring clamp, single connection, same wire range.
  • 1756-TBNH — screw clamp with double-connection option, 1.36 N·m.
  • 1756-TBSH — spring clamp, single connection, for 8-channel modules.
  • 1756-TBCHS / TBS6HS / TBNHS / TBSHS — conformal-coated versions for corrosive or condensing locations.

FAQ — 1756-TBSH / 1756TBSH Spring Clamp Terminal Block, 8-Channel

What is the 1756-TBSH?

A spring-clamp removable terminal block for ControlLogix 8-channel modules.

What wire size does it accept?

0.33…2.1 mm² (22…14 AWG), single connection only.

Can two conductors share a terminal?

No — the block is published as single connection only.

How does it differ from the 1756-TBNH?

Same module family and same single-wire range; spring clamp instead of screw clamp, and no double connection.

Which modules use it?

8-channel analog modules such as the 1756-OF6CI and 1756-IF8.

Does it need to be torqued?

No — the 1.36 N·m figure applies to the 1756-TBNH screw clamp.

What insulation rating is required?

105 °C (221 °F) or greater, 1.2 mm maximum strip.

Is there a conformal-coated version?

Yes, 1756-TBSHS.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBSH and the manufacturer's product page for 1756-TBSH. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)