Allen Bradley PLC 1756-TBNH / 1756TBNH

China Allen Bradley PLC 1756-TBNH / 1756TBNH supplier
Allen Bradley PLC 1756-TBNH / 1756TBNH supplier Allen Bradley PLC 1756-TBNH / 1756TBNH supplier Allen Bradley PLC 1756-TBNH / 1756TBNH supplier Allen Bradley PLC 1756-TBNH / 1756TBNH supplier Allen Bradley PLC 1756-TBNH / 1756TBNH supplier

Large Image :  Allen Bradley PLC 1756-TBNH / 1756TBNH

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-TBNH / 1756TBNH

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $37.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-TBNH technical data PDF download 1756-TBNH / 1756TBNH Terminal Block, Double Connection

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-TBNH (also written 1756TBNH) is the screw-clamp terminal block with the heaviest published torque and the only double-connection option in the family: one conductor 0.33…2.1 mm² (22…14 AWG), or two conductors at 0.33…1.3 mm² (22…16 AWG), terminated at 1.36 N·m (12 lb·in).

It is the block for 8-channel analog modules, and the one to specify when a point must carry a second conductor — a jumper, a shield drain or a second device on the same signal.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Removable terminal block for 8-channel modules
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-TBNH
 Type
 Screw clamp terminal block
 Sub Brand
 ControlLogix
 Mounting
 Module front, keyed
 Wire Size, Single
 0.33…2.1 mm² (22…14 AWG)
 Wire Size, Double
 0.33…1.3 mm² (22…16 AWG)
 Connections Per Terminal
 One or two, never more than two
 Wire Insulation
 105 °C (221 °F) or greater
 Insulation Strip
 1.2 mm (3/64 in) maximum
 Terminal Torque
 1.36 N·m (12 lb·in)
 Keying
 User-defined mechanical
 Conformal Version
 1756-TBNHS

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-TBNH terminal block product photograph 1756-TBNH, second view product photograph 1756-TBNH, third view product photograph

Where the terminal block sits in the panel

The double connection is the reason this block exists in a panel design. Up to two conductors may share a terminal, and the second conductor is limited to 0.33…1.3 mm² (22…16 AWG) — a 14 AWG wire cannot be doubled. The rule is explicit in the module tables: do not wire more than two conductors on any terminal.

Torque is 1.36 N·m (12 lb·in), nearly three times the 0.5 N·m of the TBCH. Where a panel mixes both blocks — common on a chassis with digital and analog modules — two torque settings apply on the same row of terminals, and a single setting used across all of them will either under-tighten the TBNH or distort the TBCH.

Wire grading is 105 °C with 1.2 mm maximum strip, and solid and stranded conductors may not be intermixed in a double connection; both must also be the same size.

Module pairing follows the channel count: 8-channel analog modules such as 1756-OF6CI and 1756-IF8 list TBNH and TBSH, while 16/32-point digital modules and the HART eight-channel output list TBCH and TBS6H. The TBNH is not a general-purpose substitute for the TBCH.

Keying is user-defined mechanical. On an analog module the keying pair distinguishes voltage and current wiring variants only at the module level, so a block moved between two analog slots carries the other slot's keying.

The conformal-coated version is 1756-TBNHS, with the same 1.36 N·m torque, the same double-connection limits, and the added requirement that only same-size wires are used with no intermixing of solid and stranded types.

Commissioning in five checks

  1. Match the block to the module family first. Eight-channel analog modules list TBNH and TBSH; the HART eight-channel output lists TBCH and TBS6H. A block that fits the slot physically may still be the wrong block for the module.
  2. Use the published torque for the block in hand, not for the module: TBCH 0.5 N·m (4.4 lb·in), TBNH 1.36 N·m (12 lb·in).
  3. Decide the double-connection question before wiring. Only TBNH accepts two conductors, and only at 0.33…1.3 mm² (22…16 AWG) for the second wire.
  4. Keep the wire at 105 °C rated insulation with a 1.2 mm maximum strip; the terminal is rated for that, and a thicker insulation will not seat.
  5. Do not intermix solid and stranded wire in a double connection, and keep both conductors the same size.

Termination faults that look like module faults

A terminal block has no diagnostics of its own; the evidence is wire strip length, conductor count per terminal, the torque figure for this block and the keying pair with the module.

 Indicator  State  Meaning and first action
 Two wires will not fit  —  Only TBNH accepts a second conductor, and only 0.33…1.3 mm² (22…16 AWG) as a double connection.
 Spring terminal will not accept a second wire  —  TBSH and TBS6H are published single-connection only; do not wire multiple conductors on any terminal.
 Fault appears after a module swap  —  RTB keying is user-defined mechanical; a block keyed for another module is not interchangeable.
 Agency mark questioned on a retrofit  —  The ControlLogix system is certified using only TBCH, TBNH, TBSH and TBS6H; other terminations can need agency approval.

Wire, torque and connection limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a terminal block

Check the torque before blaming the module: a TBNH under-torqued to the TBCH figure of 0.5 N·m is the classic cause of a drifting analog channel.

If a doubled terminal was used, confirm the second wire is 22…16 AWG; a 14 AWG second conductor is outside the published double-connection range.

Re-key and re-terminate to 1.36 N·m; do not reuse a block that has been over-torqued.

Which ControlLogix terminal block to specify

  • 1756-TBCH — screw clamp, single connection, 0.5 N·m.
  • 1756-TBS6H — spring clamp, single connection, same wire range.
  • 1756-TBNH — screw clamp with double-connection option, 1.36 N·m.
  • 1756-TBSH — spring clamp, single connection, for 8-channel modules.
  • 1756-TBCHS / TBS6HS / TBNHS / TBSHS — conformal-coated versions for corrosive or condensing locations.

FAQ — 1756-TBNH / 1756TBNH Terminal Block, Double Connection

What is the 1756-TBNH?

A screw-clamp removable terminal block for ControlLogix 8-channel modules, with a double-connection option.

What is the terminal torque?

1.36 N·m (12 lb·in).

Can two wires share a terminal?

Yes, up to two conductors, with the second at 0.33…1.3 mm² (22…16 AWG).

What single wire size does it accept?

0.33…2.1 mm² (22…14 AWG).

Can solid and stranded wire be mixed?

No — the two conductors in a double connection must be the same size and type.

Which modules use it?

8-channel analog modules such as the 1756-OF6CI and 1756-IF8.

What insulation rating is required?

105 °C (221 °F) or greater, 1.2 mm maximum strip.

Is there a conformal-coated version?

Yes, 1756-TBNHS, with the same torque and connection limits.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - removable terminal block rows: wire size, conductor count, torque and keying for 1756-TBNH and the manufacturer's product page for 1756-TBNH. Values re-checked 16 November 2026.