Allen Bradley PLC 1756-N2 / 1756N2

China Allen Bradley PLC 1756-N2 / 1756N2 supplier
Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier Allen Bradley PLC 1756-N2 / 1756N2 supplier

Large Image :  Allen Bradley PLC 1756-N2 / 1756N2

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-N2 / 1756N2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $15.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 20 PCS
Detailed Product Description

1756-N2 technical data PDF download ControlLogix 1756-N2 / 1756N2 Empty Slot Cover

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-N2 (also written 1756N2) is the ControlLogix empty slot cover: a passive slot filler for a standard ControlLogix chassis. Rockwell lists it as active, with UPC 612598167975 and a country of origin of multiple sources.

It carries no electronics and draws nothing from the backplane. Its job is mechanical and thermal: close an unused slot so the chassis airflow stays as the thermal design assumed, and keep the backplane connector covered against dust and swarf until the slot is used. The XT version of the same part is the 1756-N2XT (UPC 612598757251, country of origin United States).

1756-N2
Slot filler for standard ControlLogix chassis, active, UPC 612598167975
In stock
1756-N2XT
Slot filler for ControlLogix-XT chassis, UPC 612598757251
In stock
1756-A4
4-slot standard chassis, the smallest chassis that takes 1756-N2
In stock
1756-A7
7-slot standard chassis
In stock
1756-A13
13-slot standard chassis
In stock

 Application
 Empty slot cover
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-N2
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-N2
 Mounting
 Chassis
 Number Of Channels
 1756-N2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-N2 slot cover product photograph 1756-N2, second view product photograph 1756-N2, third view product photograph

Where the slot cover sits in a typical chassis

A partly filled chassis is the normal case in a retrofit: the original design had spare slots, and the spares are still empty. Every one of those slots is an opening in the airflow path and an exposed backplane connector.

Covers matter most in a dirty or wash-down-adjacent panel, where the backplane connector is the part you cannot clean, and in a chassis that runs near its thermal limit, where the airflow balance is the whole design margin.

They also matter for the record. A covered slot is visibly unavailable, which stops the next engineer from planning an expansion into a slot that already has a module behind a cover.

Fitting a cover in four steps

  1. Fit a cover in every slot that is not occupied by a module. An open slot changes the airflow through the chassis and leaves the backplane connector exposed.
  2. Seat it the same way as a module: it locates on the chassis rails and tightens with the same captive screw, so nothing extra is needed in the panel.
  3. Mark the slot numbers on the cover with a pencil or a printed label. The slot number is what the I/O configuration refers to, and a covered slot is easy to mis-remember at a later expansion.
  4. Record the fitted covers in the panel drawing, so a future slot-fill is planned against the real free-slot count rather than an assumption.
  5. Where the chassis is an XT chassis, use the 1756-N2XT rather than the standard cover, so the fitted part matches the coated assembly around it.

Limits: chassis fit, part identity and what it does not do

A slot cover has no indicators at all; what it has is a fit and a part identity. Every row below is taken from the Rockwell product page for this catalogue number.

 Indicator  State  Meaning and first action
 Chassis family  Standard 1756-A4, -A7, -A10, -A13, -A17  The cover is sized to a module slot, so one cover per unused slot.
 XT equivalent  1756-N2XT  Same function for the conformally coated ControlLogix-XT chassis family.
 Electronics  None  No backplane current, no configuration, no firmware; nothing to commission.
 Lifecycle  Active  Current catalogue item, not a replacement part.
 UPC  612598167975 (1756-N2), 612598757251 (1756-N2XT)  Rockwell product page identifiers, used for order matching.
 Country of origin  Multiple (1756-N2), United States (1756-N2XT)  Per the Rockwell product pages.
 Warranty  1 year standard  Rockwell standard warranty duration.

Part identity per the product pages for 1756-N2 and 1756-N2XT; chassis slot counts per 1756-TD006 (ControlLogix Chassis Specifications) and 1756-IN050.

Replacing a cover inside an installed chassis

A missing cover is replaced with the same part number, not with a module blank of another family; the cover is matched to the slot, and the slot is matched to the chassis.

In an XT chassis the standard 1756-N2 is not the right part: the coating and the corrosion qualification belong to the XT assembly, so the 1756-N2XT is the matched item.

If the slot is empty because a module was pulled for repair, fit a cover for the interval; a bare connector in a live panel is exactly the failure path that a cover removes.

Which empty-slot cover to specify

  • 1756-N2 — the slot filler for a standard ControlLogix chassis; for a 1756-A4, -A7, -A10, -A13 or -A17 with unused slots.
  • 1756-N2XT — the same function for the ControlLogix-XT chassis family, with the XT product identity and its own UPC.
  • 1756-A4 / A7 / A10 / A13 / A17 — the standard chassis the 1756-N2 is fitted to.
  • 1756-A4LXT / A5XT / A7LXT / A7XT / A10XT — the conformally coated XT chassis that takes the 1756-N2XT.
  • 1756-PA72 / PB72 / PC75 / PH75 — the power supplies that are usually specified at the same time as a chassis and its covers.

FAQ — ControlLogix 1756-N2 / 1756N2 Empty Slot Cover

What is the 1756-N2?

A ControlLogix empty slot cover, described by Rockwell as a slot filler module for standard ControlLogix chassis.

Does the 1756-N2 draw any power?

No. It is a passive cover with no electronics, so it takes no backplane current and needs no configuration.

Which chassis does it fit?

The standard ControlLogix chassis family, 1756-A4, -A7, -A10, -A13 and -A17.

What is the XT version called?

1756-N2XT, UPC 612598757251, country of origin United States.

What is the UPC of the 1756-N2?

612598167975.

Is the 1756-N2 still available?

Yes, Rockwell lists the lifecycle status as active.

How many covers does a chassis need?

One for each slot that has no module; a 1756-A13 with four spare slots needs four covers.

Why cover an empty slot at all?

To keep the chassis airflow as designed and to keep the backplane connector covered until the slot is used.


Data sources. Technical values on this page come from Rockwell publications product page for 1756-N2 / 1756-N2XT (lifecycle status, UPC, country of origin, warranty duration) and the manufacturer's product page for 1756-N2. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)