Product Details:
Payment & Shipping Terms:
|
The 1756-RMC1 (also written 1756RMC1) is the 1 m (3.28 ft) fiber-optic connector cable for a ControlLogix redundancy module pair. It is the shortest of three lengths and is ordered separately from the modules.
The cable carries the 1000 Mbps optical link between the two redundancy modules that ties the chassis pair together.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Redundancy module connector cable |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-RMC1 |
Length |
1 m (3.28 ft) |
Connector Type |
Dual LC-type (fiber-optic) |
Channels |
2 (transmit and receive fiber) |
Cable Types |
8.5/125 µm singlemode; 62.5/125 µm and 50/125 µm multimode |
Compatible Modules |
1756-RM2, 1756-RM2XT, 1756-RM3, 1756-RM3XT |
Sibling Lengths |
1756-RMC3 (3 m), 1756-RMC10 (10 m) |
Transmission |
1000 Mbps (RM3) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Length is the design constraint. The family is published as 1756-RMC1 (1 m / 3.28 ft), 1756-RMC3 (3 m / 9.84 ft) and 1756-RMC10 (10 m / 32.81 ft), so a pair of cabinets more than ten metres apart cannot be linked with these parts.
The 1 m cable is the right choice for a side-by-side rack arrangement, and it is the one that keeps the fiber run inside the cabinet rather than crossing a walkway.
Connector type is dual LC. The modules use LC-type fiber connectors, two channels — transmit and receive — so one cable assembly carries both directions.
Fiber type must match the transceiver. Published cable types for the redundancy link are 8.5/125 µm singlemode, 62.5/125 µm multimode and 50/125 µm multimode. The SFP fitted decides which applies.
It is a consumable in practice. The cable is the part most often damaged during a chassis swap, and a single damaged ferrule presents exactly like a failed module: link fault, no redundancy, healthy module.
No transceivers are included. RM3-2SFP ships with two 1783-SFP1GLX modules but still no cable, so the cable is a separate line on every order.
A redundancy fault is almost always a pairing, fiber or supply problem; the module pair tolerates a failed chassis, not a mismatched cable.
| Indicator | State | Meaning and first action |
| Redundancy module shows a link fault | — | Check the LC connector and the fiber type against the SFP fitted; singlemode and multimode fiber are not interchangeable. |
| Module draws more than expected from the chassis supply | — | 1756-RM2 draws 1.16 A at 5.1 V plus 3.4 mA at 24 V, and 1756-RM3 draws 1 A at 5.1 V plus 5 mA at 1.2 V. |
| Swap of one chassis does not restore redundancy | — | The cable must be re-terminated on the replacement module; a loose LC ferrule reads as a link failure even when the module is healthy. |
Current draw, dissipation, connector and cable data per Rockwell publication 1756-TD001-EN-P and 1756-IN050.
Order the length you need, not the nearest available; the three published lengths are the supported set.
Inspect the LC ferrules before blaming the module after a chassis swap.
Confirm the fiber type against the SFP actually fitted to the module.
What is the 1756-RMC1?
A 1 m (3.28 ft) fiber-optic connector cable for ControlLogix redundancy modules.
Which modules does it connect?
1756-RM2, RM2XT, RM3 and RM3XT pairs.
What connector type is used?
Dual LC-type fiber connectors.
What other lengths exist?
1756-RMC3 at 3 m and 1756-RMC10 at 10 m.
Which fiber types are supported?
8.5/125 µm singlemode, 62.5/125 and 50/125 µm multimode.
Is the cable supplied with the module?
No, it is ordered separately.
What link speed does the pair run at?
1000 Mbps on the RM3 modules.
Can I use a longer cable than 10 m?
No, 10 m is the published maximum length in this family.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) - redundancy module current draw, dissipation, chassis and cable data for 1756-RMC1 and the manufacturer's product page for 1756-RMC1. Values re-checked 16 November 2026.