Allen Bradley PLC 1756-OB32 / 1756OB32

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OB32 / 1756OB32

China Allen Bradley PLC 1756-OB32 / 1756OB32 supplier
Allen Bradley PLC 1756-OB32 / 1756OB32 supplier Allen Bradley PLC 1756-OB32 / 1756OB32 supplier Allen Bradley PLC 1756-OB32 / 1756OB32 supplier Allen Bradley PLC 1756-OB32 / 1756OB32 supplier Allen Bradley PLC 1756-OB32 / 1756OB32 supplier Allen Bradley PLC 1756-OB32 / 1756OB32 supplier

Large Image :  Allen Bradley PLC 1756-OB32 / 1756OB32

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB32 / 1756OB32

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $365.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description


1756-OB32 technical data PDF download 1756-OB32 ControlLogix 32 Point DC Output Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB32 (also written 1756OB32) is the 32-point DC output module: 10...31.2 V DC, 500 mA per channel at 50 °C and 350 mA at 60 °C, 1 A inrush per channel, 16 A maximum per module at 50 °C and 10 A at 60 °C, backplane 300 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V basic outputs-to-backplane, 125 V basic group-to-group (1756-IN062).

Two ceilings apply at once, and they are usually confused. Per channel 500 mA at 50 °C, but the module as a whole caps at 16 A at 50 °C — so 32 channels at 500 mA each, which would be 16 A, fills the module exactly with no headroom, and any real load profile needs the arithmetic done.

The inrush figure, 1 A per channel, is the other limit. A solenoid valve that draws 700 mA continuously and 1.4 A at pick-up is outside the published inrush allowance even though its running current fits.

Group isolation is 125 V between the two groups of sixteen, with none inside a group. That is a shared-return design: two 24 V sources can be used, and each group's sixteen outputs share their return.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB32
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 32
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB32 module product photograph 1756-OB32 label product photograph 1756-OB32 terminal side product photograph

Where the module sits in a typical system

The OB32 is the density choice for panels with a large, mostly uniform 24 V DC output list: dozens of solenoid valves and indicator lamps on one card, with the module total worked out at 50 °C and again at 60 °C.

Because inrush is capped at 1 A per channel, it suits valves and lamps rather than contactors; a contractor with a high pick-up current belongs on a 2 A pilot duty module.

Two groups of sixteen allow a split supply — one group from the machine's 24 V supply, the second from a separate source — inside the 125 V group barrier.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 10 A at 60 °C The module ceiling drops by 6 A between 50 and 60 °C.
 Check 3 1 A inrush per channel Running current can fit while inrush does not. Check the coil's pick-up current.
 Check 4 125 V group-to-group Two groups of sixteen with shared returns inside each group.
 Check 5 300 mA backplane Nearly double a 16-point card's draw on the 5.1 V rail for twice the channels — still the better density.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 2 A per point with 250 V reinforced isolation, 1756-OB16I halves the channel count.

For 16 points at 1 A with 2 A inrush, 1756-OB16E is the standard 16-channel card.

For diagnostic outputs, 1756-OB16D publishes per-point load monitoring.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB32 ControlLogix 32 Point DC Output Module | Rockwell

What is the 1756-OB32?

A 32-point DC output module, 10...31.2 V DC, 500 mA per channel at 50 °C and 350 mA at 60 °C.

What is the module maximum current?

16 A at 50 °C and 10 A at 60 °C.

What is the inrush rating?

1 A per channel.

How is it isolated?

250 V continuous basic outputs-to-backplane and 125 V basic between the two groups of sixteen.

How much backplane current does it draw?

300 mA at 5.1 V DC and 2 mA at 24 V DC.

Can all 32 channels run at 500 mA?

Only if the module total allows it: 32 x 500 mA is exactly the 16 A rating at 50 °C, with no margin.

What is the temperature code?

T4A, with 60 °C maximum surrounding air.

Which document publishes these figures?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB32. Values re-checked 15 November 2026.