1785-RC is a relay cartridge that sits in the PLC-5 processor and gives an external circuit a volt-free contact that opens whenever the controller detects a program edit or an I/O force request.
Installation is covered by 1785-IN001. The cartridge seats in the processor mating connector with the keying pins down, and the user supplies 120 V AC which the internal relay switches.
| 1785-ACC5LA | PLC-5 accessory kit | IN STOCK |
| 1785-ACC5LB | PLC-5 accessory kit | IN STOCK |
| 1785-CHBM | ControlNet backup cartridge | IN STOCK |
| 1785-ENET | PLC-5 Ethernet interface module | IN STOCK |
| 1785-L26B | PLC-5/26 protected processor, 16 K words | IN STOCK |
| 1785-L40C15 | PLC-5 ControlNet 1.5 processor, 48 K words | IN STOCK |
| 1785-L40C | PLC-5 ControlNet 1.25 processor, 48 K words | IN STOCK |
| 1785-L46C15 | PLC-5/46C ControlNet 1.5 protected processor | IN STOCK |
| 1785-L40E | PLC-5/40E Ethernet processor, 48 K words | IN STOCK |
| 1785-L60B | PLC-5/60 processor, 64 K words | IN STOCK |
| 1785-L60L | PLC-5/60L processor with extended local I/O | IN STOCK |
| 1785-L80C | PLC-5 ControlNet 1.25 processor, 100 K words | IN STOCK |
| 1785-L80B | PLC-5/80 processor, 100 K words | IN STOCK |
| 1785-L80C15 | PLC-5 ControlNet 1.5 processor, 100 K words | IN STOCK |
| 1785-L80E | PLC-5/80E Ethernet processor, 100 K words | IN STOCK |
| 1785-L86B | PLC-5/86 protected processor, 100 K words | IN STOCK |
| 1785-M100 | 100 K word memory module | IN STOCK |
| 1785-ME16 | 16 K word EEPROM memory cartridge | IN STOCK |
| 1785-ME32 | 32 K word EEPROM memory cartridge | IN STOCK |
| 1785-ME64 | 64 K word EEPROM memory cartridge | IN STOCK |
| 1785-RC | Relay cartridge, edit and force monitoring | IN STOCK |
Catalog number |
1785-RC |
Product type |
PLC-5 relay cartridge |
Function |
Edit and force monitoring relay |
Compatible controllers |
PLC-5/40B, PLC-5/60B, PLC-5/80B |
Firmware requirement |
Series E, revision E |
External supply |
120 V AC, supplied by the user |
Lifecycle status |
Discontinued |
Discontinued date |
Not published |
Replacement category |
Not published |
UPC |
Not published |
Country of origin |
Not published |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1785-IN001 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
1785-RC is a relay cartridge that sits in the PLC-5 processor and gives an external circuit a volt-free contact that opens whenever the controller detects a program edit or an I/O force request.
It exists for regulated processes: the contact drives an external device such as a 700P relay, so a change to the running program leaves a physical trace outside the controller.
Installation is covered by 1785-IN001. The cartridge seats in the processor mating connector with the keying pins down, and the user supplies 120 V AC which the internal relay switches.
It is compatible with the PLC-5/40B, /60B and /80B controllers and requires Series E, revision E firmware; a lower firmware revision will not provide the status bits.
The cartridge is no longer an orderable PLC-5 item. Rockwell's product records used here do not print a discontinued date for it, so none is quoted.
Four status bits report the cartridge state: external 120 V AC present, relay driven open, contact state, and cartridge installed.
These cartridges are bought by plants with validation obligations that still run a PLC-5: pharmaceutical, food and specialty chemical lines where an edit must be visible outside the controller.
When one fails, the replacement search is usually urgent, because the validation record depends on the function being present.
Confirm the controller model is one of the three supported, and that the processor firmware is at Series E, revision E, before expecting the status bits to work.
Ask for the cartridge to be tested in a compatible processor, and check the connector for bent pins.
What does 1785-RC do?
It opens a relay contact when a program edit or I/O force request is detected.
Which controllers support it?
PLC-5/40B, /60B and /80B, per 1785-IN001.
What firmware is required?
Series E, revision E.
Does it need external power?
Yes, the user supplies 120 V AC for the switched circuit.
What should I check before buying?
Controller compatibility, firmware revision and connector condition.