logo
Home ProductsAB DH-485 Network 1784

Allen Bradley PLC 1784-CP10 / 1784CP10

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1784-CP10 / 1784CP10

China Allen Bradley PLC 1784-CP10 / 1784CP10 supplier
Allen Bradley PLC 1784-CP10 / 1784CP10 supplier Allen Bradley PLC 1784-CP10 / 1784CP10 supplier Allen Bradley PLC 1784-CP10 / 1784CP10 supplier Allen Bradley PLC 1784-CP10 / 1784CP10 supplier Allen Bradley PLC 1784-CP10 / 1784CP10 supplier

Large Image :  Allen Bradley PLC 1784-CP10 / 1784CP10

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1784-CP10 / 1784CP10

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $85.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1784-CP10 technical data PDF download 1784-CP10 Rockwell PLC-5 Communication Cable

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Bulletin 1784 · PC interface cards and cables

1784-CP10 is the PLC-5 communication cable for the serial programming route, published as 1784-TD032.

The cable is documented in technical data 1784-TD032. Rockwell also lists it as the shielded serial cable to use with the PLC-5 flash tool when a processor is updated over the serial port.

1784-U2DN USB to DeviceNet adapter, PCMCIA-era replacement IN STOCK
1784-U2CN USB to ControlNet adapter cable IN STOCK
1784-SD2 Industrial 2 GB Secure Digital card IN STOCK
1784-SD1 Industrial 1 GB Secure Digital card IN STOCK
1784-PKTXD DH+ / RIO / DH-485 dual channel PCI card IN STOCK
1784-PKTCS ControlNet 1.5 PC card IN STOCK
1784-PCM6 DH+ cable, 8-pin mini-DIN IN STOCK
1784-PCM5 PLC-5 / PCMCIA DH+ cable IN STOCK
1784-PCM4 DH-485 cable for SLC 5/01 to 5/03 IN STOCK
1784-PCM2 PLC-2 cable for the PCMK card IN STOCK
1784-PCIDS DeviceNet PCI scanner card IN STOCK
1784-PCICS ControlNet PCI scanner card IN STOCK
1784-PCIC ControlNet PCI card, redundant media IN STOCK
1784-PCD1 DeviceNet PCMCIA interface cable IN STOCK
1784-PCC1 ControlNet PCMCIA interface cable IN STOCK
1784-CP8 62-pin D-shell to 3-pin Phoenix adapter IN STOCK
1784-CP7 CP / CP5 to PLC-5 DIN adapter IN STOCK
1784-CP6 KT / KT2 / KL to PLC-5 cable, 3.05 m IN STOCK
1784-CP14 DH-485 cable, Phoenix to RJ45, 3.2 m IN STOCK
1784-CP11 PLC-5 serial programming cable IN STOCK
1784-CP10 PLC-5 serial programming cable IN STOCK
1784-CP PLC-3 communication cable IN STOCK

Product Specifications 1784-CP10 (PDF)
 Catalog number
 1784-CP10
 Product type
 PLC-5 communication cable
 Lifecycle status
 Discontinued December 31, 2019
 Replacement category
 No planned RA replacement
 UPC
 612598120826
 Used for
 Serial programming of PLC-5 processors
 Country of origin
 United States of America
 Warranty
 1 year
 Publication
 1784-TD032

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1784-TD032 (module specifications) and 1784-TD032 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1784-CP10 1784-CP10

What it connects

1784-CP10 is the PLC-5 communication cable for the serial programming route, published as 1784-TD032.

It belongs to the same serial family as the CP11: the difference is the computer port it mates with, which is why both catalog numbers still appear in PLC-5 programming tables.

Interface and cabling

Because the flash tool loads firmware, the cable's shielding matters more here than on a programming lead: a noisy link during a flash is a bricked processor.

Lifecycle and replacement

Discontinued December 31, 2019 and no planned Rockwell replacement — one of the harsher withdrawals in this bulletin.

The wiring is published, so a replacement can be built; what cannot be bought is the original assembly.

Where these are still in use

Programming and firmware flashing of PLC-5 processors over the serial port, including the flash tool route Rockwell documents.

Service work on processors where channel 0 is the only reliable connection.

Buying a used unit

Confirm the cable is the shielded serial type and check continuity end to end; for flashing work, do not substitute an unshielded lead.

Inspect the D-shell pins — a bent pin on a 25-pin connector is easy to miss and produces intermittent failures.

FAQ — 1784-CP10

What does 1784-CP10 connect?

1784-CP10 is the PLC-5 communication cable for the serial programming route, published as 1784-TD032.

Is 1784-CP10 still available from Rockwell?

No. Discontinued December 31, 2019, with no planned Rockwell replacement.

What replaces 1784-CP10?

No planned Rockwell replacement is named; the wiring is published in 1784-TD032 for an equivalent lead.

Where does 1784-CP10 sit in the system?

Programming and firmware flashing of PLC-5 processors over the serial port, including the flash tool route Rockwell documents.

What should I check before buying 1784-CP10?

Shielding, continuity and the D-shell pins.


Data sources. Product type, UPC, lifecycle status and discontinued date come from the Rockwell product page of 1784-CP10; serial cable and flash tool use from 1785-UM002. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1784-CP10

This page documents catalog number 1784-CP10, a 1784 DH-485 / Data Highway Plus programming accessory, as published by Rockwell Automation in the installation data sheets and processor manuals cited in the table. Every value below comes from those documents; nothing is inferred.

Published facts for this catalog number

SpecificationValue
FunctionSerial programming cable from an IBM AT or compatible computer to a PLC-5 processor with an RS-232 port
Computer-side connector9-pin female
Processor-side connector25-pin male
Cable length3.2 m (10 ft)
Processors servedPLC-5/11, -5/20, -5/30, -5/40, -5/60, -5/40L, -5/60L
Terminals servedT35 plant-floor terminal, T47, T48, T50 and T53 programming terminals, T60 industrial workstation, 6121 industrial processor
Computers servedIBM AT, Compaq Portable 2, Compaq Portable 286, Compaq Deskpro 286, Compaq Deskpro 386
Publication1784-2.32, April 1993

What the cable has to match

Three things have to line up before this part does any work: the connector at the computer or card end, the connector at the processor end, and the processor family the cable was published for. The table above states all three wherever the source documents state them. Where a document is silent, the row says so rather than carrying a plausible substitute, because a plausible substitute in a cable table is how a wrong part gets ordered.

Consequences on site

Every cable on this page terminates at a processor port that is still used for program uploads and for fault diagnosis. That makes the mechanical state of the connector part of the maintenance schedule: a shell that has been tightened with pliers, or a latch that no longer clicks, is a link that will fail during the one upload that matters.

Every cable on this page terminates at a processor port that is still used for program uploads and for fault diagnosis. That makes the mechanical state of the connector part of the maintenance schedule: a shell that has been tightened with pliers, or a latch that no longer clicks, is a link that will fail during the one upload that matters.

These cables were published for a generation of computers that no longer exists in most plants. What survives is the processor, so the practical question is usually whether the cable can be used with a current PC through a converter. The answer depends on the pin mapping at the computer end, which is why the connector type is stated rather than left to a photograph.

Scope of the published data

Only values that appear in the cited Rockwell Automation publications are printed here. Cable length is listed only where the document states it; a length that is not published is marked as not published rather than taken from a distributor listing. Where two Rockwell publications describe the same catalog number differently, both statements are shown with their source, and no attempt is made to decide between them. Pin-level wiring is not reproduced on this page: it belongs to the publication for the specific cable, and a supplier page is not the right place to reconstruct it.

The 62-pin D-shell end on the DH+ cables is the interface to an ISA card that sits inside the programming computer. That connector carries the parallel bus interface rather than a serial line, which is why these cables are short and why they cannot be extended with a serial patch cord. A cable that has been lengthened in the field, or one whose 62-pin shell has been tightened unevenly, produces intermittent communication that looks like a software fault.

The processors named on this page are the ones the cable was published for, and the list is narrow on purpose. A cable built for a PLC-5 serial port does not serve a PLC-2 program panel connector, and the DH+ cables do not serve a DH-485 port even though both are eight-pin round connectors on some processors. Compatibility is a published statement, and a page that repeats it saves a purchase order that would otherwise be returned.

An obsolete cable still has a function in a plant that has not migrated: it keeps a processor programmable. The economics are simple, because the alternative is an interface upgrade that touches the network, the software and the procedures. What the plant needs from the supplier is certainty about which catalog number fits which processor, and that certainty comes from the compatibility table rather than from a photograph.

Serial programming on these processors is a null modem connection in the physical sense: transmit crosses to receive and the handshake lines are strapped. A cable wired straight through will not communicate, and no amount of port configuration will fix it. When a site has lost the original cable and a substitute is being made, the pin mapping has to come from the publication for the specific cable rather than from a generic serial diagram, because the processor side uses a different pin count and a different strapping pattern.

Where a plant still programs a PLC-5 or an SLC from a laptop, the practical replacement path is a modern interface rather than a rebuilt cable. That path needs the same information this page carries: which port on the processor, which protocol, and what the original cable did. Keeping the original catalog number in the maintenance record is what allows that decision to be made later without pulling a panel apart to look at a connector.

Where the same catalog number turns up with a different connector count in two Rockwell publications, the honest answer is that both statements exist. One document describes the packing data for the cable, the other describes its use with a terminal family, and the difference is usually a revision rather than an error. Declaring both, with the publication each came from, is better than choosing one and being wrong for half the installed base.

The difference between a 9-pin and a 25-pin serial connector on the computer end is not cosmetic. It decides which vintage of PC the cable was made for, and a cable built for a 25-pin port will not fit a 9-pin port without an adapter whose pin mapping has to be checked. Because both cables carry the same PLC-side connector, a spare ordered by catalog number is the only reliable way to get the right combination of ends.

Cable length limits on these networks are published as a distance at a given data rate, not as a maximum cable length for the cable itself. The 10,000 ft figure at 57.6 kbaud for a DH+ link through an ISA card is a network figure that includes every node and every drop, so a longer cable does not buy a longer network. Reading the figure as a cable specification is a common mistake that shows up as intermittent faults at one end of a long trunk.

A DH-485 link built with a programming cable is a temporary connection, and treating it as permanent is how cabinets end up with a programming port hanging inside a live enclosure. The cable is not rated for continuous flexing, its connector is not a field-installable network connector, and the card it serves expects to be inside a computer that is switched off before the cable is removed.

A programming cable is the part of a control system that survives longest and gets documented least. The card it plugs into is obsolete, the software that used it is obsolete, and the cable itself is still in a drawer because it was never thrown away. That is exactly why the connector types and the compatible processor list belong on a product page: the person looking for one of these is usually matching a cable to a processor that is already running, not designing a new network.

Termination on a DH+ or DH-485 link is a property of the physical ends of the trunk, and the cable at the programming end sometimes carries a switchable resistor for exactly that reason. A programming cable with the resistor switched in, left connected to a network that is already terminated at both ends, adds a third termination and degrades the signal. The switch is there to be set for the situation, not left in the position it arrived in.

Documentation for these parts predates the web. Several of the installation data sheets were published in the early 1990s and are still the only authoritative source for connector types and processor compatibility. That is why the publication numbers are quoted on this page: an engineer verifying a claim can go to the document rather than to a distributor's description, and the two do not always agree.

The processors these cables serve are still in production in plenty of plants, and the cable is the weakest link in the chain that keeps them programmable. Publishing the connector types, the processor list and the publication number turns a cable into a documented part; leaving those out leaves a buyer comparing photographs on distributor sites and hoping the pin count matches.

Adapters exist because one card family has to reach several processor generations. The adapter carries the pin remapping and sometimes the termination, so pairing the wrong adapter with a cable produces a physical connection that appears correct and does not communicate on the network. The published pairing tables in the processor manuals are the authority here, and they name the cable and the adapter as a pair rather than as interchangeable parts.

Programming cables are handled far more often than any other part in a control panel, because they are plugged and unplugged every time somebody needs to look at a program. The failure mode is therefore mechanical: a bent shell, a cracked Phoenix connector, a broken latch. A spare kept in the panel, labelled with the catalog number, is cheaper than a production stop while somebody traces a five-dollar connector through a distributor's inventory.

Cables, cards and adapters for the same 1784 range are listed in the 1784 DH-485 category. This item itself can be checked against the shop listing at 1784-CP10.

Related models, options and spare parts for this range are listed in the Allen-Bradley 1784 DH-485 and DH+ modules category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925