logo
Home ProductsAB DH-485 Network 1784

Allen Bradley PLC 1784-CP / 1784CP

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1784-CP / 1784CP

China Allen Bradley PLC 1784-CP / 1784CP supplier
Allen Bradley PLC 1784-CP / 1784CP supplier Allen Bradley PLC 1784-CP / 1784CP supplier Allen Bradley PLC 1784-CP / 1784CP supplier Allen Bradley PLC 1784-CP / 1784CP supplier Allen Bradley PLC 1784-CP / 1784CP supplier

Large Image :  Allen Bradley PLC 1784-CP / 1784CP

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1784-CP / 1784CP

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $228.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1784-CP technical data PDF download 1784-CP Rockwell PLC-3 Communication Cable

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Bulletin 1784 · PC interface cards and cables

1784-CP is the PLC-3 communication cable — the original member of the CP family, from the era when a programming terminal was a desktop with an interface card in a slot.

The cable is documented in 1784-TD026, which lists the card and cable combinations: 1784-KTK1 with CP5 and CP7, 1784-KT with CP6 or CP plus CP7.

1784-U2DN USB to DeviceNet adapter, PCMCIA-era replacement IN STOCK
1784-U2CN USB to ControlNet adapter cable IN STOCK
1784-SD2 Industrial 2 GB Secure Digital card IN STOCK
1784-SD1 Industrial 1 GB Secure Digital card IN STOCK
1784-PKTXD DH+ / RIO / DH-485 dual channel PCI card IN STOCK
1784-PKTCS ControlNet 1.5 PC card IN STOCK
1784-PCM6 DH+ cable, 8-pin mini-DIN IN STOCK
1784-PCM5 PLC-5 / PCMCIA DH+ cable IN STOCK
1784-PCM4 DH-485 cable for SLC 5/01 to 5/03 IN STOCK
1784-PCM2 PLC-2 cable for the PCMK card IN STOCK
1784-PCIDS DeviceNet PCI scanner card IN STOCK
1784-PCICS ControlNet PCI scanner card IN STOCK
1784-PCIC ControlNet PCI card, redundant media IN STOCK
1784-PCD1 DeviceNet PCMCIA interface cable IN STOCK
1784-PCC1 ControlNet PCMCIA interface cable IN STOCK
1784-CP8 62-pin D-shell to 3-pin Phoenix adapter IN STOCK
1784-CP7 CP / CP5 to PLC-5 DIN adapter IN STOCK
1784-CP6 KT / KT2 / KL to PLC-5 cable, 3.05 m IN STOCK
1784-CP14 DH-485 cable, Phoenix to RJ45, 3.2 m IN STOCK
1784-CP11 PLC-5 serial programming cable IN STOCK
1784-CP10 PLC-5 serial programming cable IN STOCK
1784-CP PLC-3 communication cable IN STOCK

Product Specifications 1784-CP (PDF)
 Catalog number
 1784-CP
 Product type
 PLC-3 communication cable
 Lifecycle status
 Discontinued May 25, 2017
 Replacement category
 Engineering Replacement
 Country of origin
 United States of America
 Warranty
 1 year
 Used with
 1784-KT and 1784-KTK1 interface cards, with 1784-CP7 for PLC-5
 Publication
 1784-TD026

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1784-TD026 (module specifications) and 1784-TD026 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1784-CP 1784-CP

What it connects

1784-CP is the PLC-3 communication cable — the original member of the CP family, from the era when a programming terminal was a desktop with an interface card in a slot.

Its second life is on PLC-5: combined with the 1784-CP7 adapter it reaches enhanced processors, which is why the two parts are usually found together.

Interface and cabling

So CP is not a stand-alone route to a PLC-5 DH+ port; it needs the CP7 adapter for the mini-DIN connection unless the processor end is the older connector.

Lifecycle and replacement

Discontinued May 25, 2017, replacement category Engineering Replacement — the earliest withdrawal of the CP cables in this bulletin.

PLC-3 controllers themselves are museum pieces in most plants, so the practical demand is for PLC-5 kits that were built around this cable.

Where these are still in use

PLC-3 programming where a controller is still in service, and PLC-5 programming through CP plus CP7.

Completing a legacy kit whose cable is present but whose adapter has been lost.

Buying a used unit

Check the D-shell and the cable jacket for cracks; a 1990s assembly that has been coiled in a cabinet for decades fails at the connector first.

Confirm the intended use — PLC-3 direct, or PLC-5 through the CP7 adapter — before buying, since the adapter is a separate part.

FAQ — 1784-CP

What does 1784-CP connect?

1784-CP is the PLC-3 communication cable — the original member of the CP family, from the era when a programming terminal was a desktop with an interface card in a slot.

Is 1784-CP still available from Rockwell?

No. Discontinued May 25, 2017; replacement category Engineering Replacement.

What replaces 1784-CP?

Rockwell names no stocked successor; support is case by case.

Where does 1784-CP sit in the system?

PLC-3 programming where a controller is still in service, and PLC-5 programming through CP plus CP7.

What should I check before buying 1784-CP?

The D-shell pins, the jacket, and whether a CP7 adapter is needed.


Data sources. Product type, lifecycle status and discontinued date come from the Rockwell product page of 1784-CP; cable combinations from 1784-TD026. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1784-CP

This page documents catalog number 1784-CP, a 1784 DH-485 / Data Highway Plus programming accessory, as published by Rockwell Automation in the installation data sheets and processor manuals cited in the table. Every value below comes from those documents; nothing is inferred.

Published facts for this catalog number

SpecificationValue
FunctionProgramming cable from a 1784-KT series communication interface card to a PLC-5 family processor
Card-side connector62-pin D-shell, secured with captive screws
Processor-side connectionPLC-5 peer communication interface connector
Processors served directlyPLC-5/10, -5/12, -5/15, -5/25, PLC-5/250, PLC-5/VME (6008-LTV)
Processors served with 1784-CP7 adapterPLC-5/11, -5/20, -5/30, -5/40, -5/60, -5/80, PLC-5/VME (1784-V40)
Publication for the card1784-6.5.22, 1784-KTx Communication Interface Card User Manual
Cable lengthNot published in the installation data retrieved for this page

What the cable has to match

Three things have to line up before this part does any work: the connector at the computer or card end, the connector at the processor end, and the processor family the cable was published for. The table above states all three wherever the source documents state them. Where a document is silent, the row says so rather than carrying a plausible substitute, because a plausible substitute in a cable table is how a wrong part gets ordered.

Consequences on site

The processor list is the specification that matters most on this page, because a programming cable is bought against a processor rather than against a network. A cable that reaches a PLC-5/25 does not reach a PLC-5/40 without the adapter that the manual names, and the two part numbers are easy to confuse at a distributor's counter.

The processor list is the specification that matters most on this page, because a programming cable is bought against a processor rather than against a network. A cable that reaches a PLC-5/25 does not reach a PLC-5/40 without the adapter that the manual names, and the two part numbers are easy to confuse at a distributor's counter.

Every cable on this page terminates at a processor port that is still used for program uploads and for fault diagnosis. That makes the mechanical state of the connector part of the maintenance schedule: a shell that has been tightened with pliers, or a latch that no longer clicks, is a link that will fail during the one upload that matters.

Scope of the published data

Only values that appear in the cited Rockwell Automation publications are printed here. Cable length is listed only where the document states it; a length that is not published is marked as not published rather than taken from a distributor listing. Where two Rockwell publications describe the same catalog number differently, both statements are shown with their source, and no attempt is made to decide between them. Pin-level wiring is not reproduced on this page: it belongs to the publication for the specific cable, and a supplier page is not the right place to reconstruct it.

The difference between a 9-pin and a 25-pin serial connector on the computer end is not cosmetic. It decides which vintage of PC the cable was made for, and a cable built for a 25-pin port will not fit a 9-pin port without an adapter whose pin mapping has to be checked. Because both cables carry the same PLC-side connector, a spare ordered by catalog number is the only reliable way to get the right combination of ends.

Cable length limits on these networks are published as a distance at a given data rate, not as a maximum cable length for the cable itself. The 10,000 ft figure at 57.6 kbaud for a DH+ link through an ISA card is a network figure that includes every node and every drop, so a longer cable does not buy a longer network. Reading the figure as a cable specification is a common mistake that shows up as intermittent faults at one end of a long trunk.

A DH-485 link built with a programming cable is a temporary connection, and treating it as permanent is how cabinets end up with a programming port hanging inside a live enclosure. The cable is not rated for continuous flexing, its connector is not a field-installable network connector, and the card it serves expects to be inside a computer that is switched off before the cable is removed.

A programming cable is the part of a control system that survives longest and gets documented least. The card it plugs into is obsolete, the software that used it is obsolete, and the cable itself is still in a drawer because it was never thrown away. That is exactly why the connector types and the compatible processor list belong on a product page: the person looking for one of these is usually matching a cable to a processor that is already running, not designing a new network.

Termination on a DH+ or DH-485 link is a property of the physical ends of the trunk, and the cable at the programming end sometimes carries a switchable resistor for exactly that reason. A programming cable with the resistor switched in, left connected to a network that is already terminated at both ends, adds a third termination and degrades the signal. The switch is there to be set for the situation, not left in the position it arrived in.

Documentation for these parts predates the web. Several of the installation data sheets were published in the early 1990s and are still the only authoritative source for connector types and processor compatibility. That is why the publication numbers are quoted on this page: an engineer verifying a claim can go to the document rather than to a distributor's description, and the two do not always agree.

The processors these cables serve are still in production in plenty of plants, and the cable is the weakest link in the chain that keeps them programmable. Publishing the connector types, the processor list and the publication number turns a cable into a documented part; leaving those out leaves a buyer comparing photographs on distributor sites and hoping the pin count matches.

Adapters exist because one card family has to reach several processor generations. The adapter carries the pin remapping and sometimes the termination, so pairing the wrong adapter with a cable produces a physical connection that appears correct and does not communicate on the network. The published pairing tables in the processor manuals are the authority here, and they name the cable and the adapter as a pair rather than as interchangeable parts.

Programming cables are handled far more often than any other part in a control panel, because they are plugged and unplugged every time somebody needs to look at a program. The failure mode is therefore mechanical: a bent shell, a cracked Phoenix connector, a broken latch. A spare kept in the panel, labelled with the catalog number, is cheaper than a production stop while somebody traces a five-dollar connector through a distributor's inventory.

Connector shells and thumb screws are part of the electrical specification on these cables, not accessories. A D-shell that is not fully seated produces a connection that passes a continuity test and fails under the load of a program upload. Any inspection procedure for a legacy programming link should include the mechanical condition of both ends, because that is where these cables fail.

The 62-pin D-shell end on the DH+ cables is the interface to an ISA card that sits inside the programming computer. That connector carries the parallel bus interface rather than a serial line, which is why these cables are short and why they cannot be extended with a serial patch cord. A cable that has been lengthened in the field, or one whose 62-pin shell has been tightened unevenly, produces intermittent communication that looks like a software fault.

The processors named on this page are the ones the cable was published for, and the list is narrow on purpose. A cable built for a PLC-5 serial port does not serve a PLC-2 program panel connector, and the DH+ cables do not serve a DH-485 port even though both are eight-pin round connectors on some processors. Compatibility is a published statement, and a page that repeats it saves a purchase order that would otherwise be returned.

An obsolete cable still has a function in a plant that has not migrated: it keeps a processor programmable. The economics are simple, because the alternative is an interface upgrade that touches the network, the software and the procedures. What the plant needs from the supplier is certainty about which catalog number fits which processor, and that certainty comes from the compatibility table rather than from a photograph.

Serial programming on these processors is a null modem connection in the physical sense: transmit crosses to receive and the handshake lines are strapped. A cable wired straight through will not communicate, and no amount of port configuration will fix it. When a site has lost the original cable and a substitute is being made, the pin mapping has to come from the publication for the specific cable rather than from a generic serial diagram, because the processor side uses a different pin count and a different strapping pattern.

Where a plant still programs a PLC-5 or an SLC from a laptop, the practical replacement path is a modern interface rather than a rebuilt cable. That path needs the same information this page carries: which port on the processor, which protocol, and what the original cable did. Keeping the original catalog number in the maintenance record is what allows that decision to be made later without pulling a panel apart to look at a connector.

Cables, cards and adapters for the same 1784 range are listed in the 1784 DH-485 category. This item itself can be checked against the shop listing at 1784-CP.

The Allen-Bradley 1784 DH-485 and DH+ modules category lists the related catalog numbers, options and accessories for this range.