logo
Home ProductsAB Network Switches 1783

Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F

China Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier
Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F supplier

Large Image :  Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1783-ETAP2F / 1783ETAP2F

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $521.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 3 PCS
Detailed Product Description

1783-ETAP2F technical data PDF download 1783-ETAP2F Rockwell 1+2 Port EtherNet/IP Tap

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Stratix 5700 / 8000 / 8300 / 2000 · 1783

1783-ETAP2F is an EtherNet/IP tap: a small device that lets several nodes join a device-level ring without a switch, and that keeps that ring intact when a node is unplugged.

It is what makes a line-level ring practical — the tap owns the ring ports, so the controller needs only one Ethernet connection.

1783-BMS20CL Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP IN STOCK
1783-BMS20CGP Stratix 5700, 20 ports, gigabit combo IN STOCK
1783-BMS20CGL Stratix 5700, 20 ports, gigabit combo, Lite firmware IN STOCK
1783-BMS20CGPK Stratix 5700, 20 ports, gigabit combo, kit IN STOCK
1783-BMS06TA Stratix 5700, 6 copper ports IN STOCK
1783-BMS06TL Stratix 5700, 6 copper ports, Lite firmware IN STOCK
1783-BMS06TGA Stratix 5700, 4 copper + 2 gigabit copper IN STOCK
1783-BMS06SA Stratix 5700, 4 copper + 2 SFP IN STOCK
1783-BMS06SL Stratix 5700, 4 copper + 2 SFP, Lite firmware IN STOCK
1783-BMS06SGA Stratix 5700, 4 copper + 2 gigabit SFP IN STOCK
1783-BMS06SGL Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware IN STOCK
1783-MS06T Stratix 8000, 6 port chassis IN STOCK
1783-MS10T Stratix 8000, 10 port chassis IN STOCK
1783-RMS06T Stratix 8300, 6 port layer 3 IN STOCK
1783-RMS10T Stratix 8300, 10 port layer 3 IN STOCK
1783-EMS04T Stratix 6000, 4 port managed IN STOCK
1783-MX08T Stratix 8000 copper 8 port expansion IN STOCK
1783-MX08F Stratix 8000 fibre 8 port expansion IN STOCK
1783-MCF Stratix 8000 CompactFlash spare card IN STOCK
1783-RMCF Stratix 8300 CompactFlash spare card IN STOCK
1783-ETAP EtherNet/IP tap, 3 copper ports IN STOCK
1783-ETAP2F EtherNet/IP tap, 1 copper + 2 fibre IN STOCK
1783-SFP100FX 100FX multimode SFP, 2 km IN STOCK
1783-SFP100LX 100LX singlemode SFP, 10 km IN STOCK
1783-SFP1GSX 1000SX multimode SFP, 550 m IN STOCK
1783-SFP1GLX 1000LX singlemode SFP, 10 km IN STOCK
1783-US8T Stratix 2000, 8 copper ports, unmanaged IN STOCK
1783-US03T01F Stratix 2000, 3 copper + 1 fibre, unmanaged IN STOCK

Product Specifications 1783-ETAP2F (PDF)
 Catalog number
 1783-ETAP2F
 Description
 EtherNet/IP tap
 Ports
 1 copper port plus 2 fibre ports
 Interface
 1 * copper RJ45, 2 * fibre
 Power supply
 24V dc
 Lifecycle status
 Discontinued August 31, 2026
 Replacement category
 Engineering Replacement
 Replacement product
 1783-ETAP1T2SFP
 Country of origin
 United States
 Publication
 1783-UM011

Same-family catalog numbers: 1783-ETAP2F. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1783 family.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1783-ETAP2F 1783-ETAP2F 1783-ETAP2F

What a tap does

1 copper port plus 2 fibre ports, powered from 24V dc.

In a device-level ring (DLR) the tap sits between the two ring ports and presents one copper port to the device. Losing the device does not break the ring; losing the tap does.

When to use one

Where the controller has a single Ethernet port and the topology has to survive a cable break — a conveyor line, a packaging machine, a process skid.

Where a managed switch would be overkill: a tap has no management, no addressing plan and nothing to configure.

Copper and fibre versions

1783-ETAP is three copper ports; 1783-ETAP2F is one copper port plus two fibre ports for a ring that crosses between cabinets.

Fibre on the ring is what makes the distance work. Copper taps stop at the enclosure wall for practical reasons, not because the standard forbids more.

Lifecycle

Discontinued August 31, 2026, replacement category Engineering Replacement, replacement product 1783-ETAP1T2SFP.

Taps are overlooked in spares planning because they look passive. A line with ten taps and no spare stops at the first failed tap.

Buying used

Check the ports for bent pins and confirm which variant the unit is — copper and fibre taps look similar from the front.

Country of origin for this catalog number is the United States, which matters for lead time on any remaining new stock.

FAQ — 1783-ETAP2F

What is 1783-ETAP2F?

An EtherNet/IP tap — 1 copper port plus 2 fibre ports.

What power does 1783-ETAP2F need?

24V dc.

Is 1783-ETAP2F still available from Rockwell?

No. Discontinued August 31, 2026; replacement category Engineering Replacement.

What replaces 1783-ETAP2F?

1783-ETAP1T2SFP

Where is 1783-ETAP2F used?

In device-level rings, to keep the ring intact when a device is disconnected.


Data sources. Port composition, interface and supply come from the Rockwell product page of this catalog number. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1783-ETAP2F: fiber dual-port EtherNet/IP tap

1783-ETAP2F is part of the Allen-Bradley Stratix industrial Ethernet range, described here from the Rockwell technical data and installation instructions so that the supply, the isolation and the temperature limits on the page are the ones an integrator can actually design against.

SpecificationValue
Tap typeFiber, dual-port EtherNet/IP tap with two fiber ports
Current consumption260 mA maximum at 24V DC
Power6.24 W consumption, 6.24 W dissipation
Supply rating24V DC, 20.4 to 27.6V DC, Class 2 or SELV
Fiber type62.5/125 and 50/125 micron multimode, graded index per IEC 60793-2-10 category A1
Power budget12.8 dB on 62.5/125 micron, 9.3 dB on 50/125 micron, for two connected taps at rated bit error rate
ConnectorLC per IEC 61754-20, maximum insertion loss 0.75 dB per connection
Channel lengthMaximum 2 km, and the connectors plus cable must stay inside the published power budget
ReceiverSensitivity -31.8 dBm minimum to -14 dBm maximum
Isolation30V continuous basic insulation, type tested 853V AC for 60 s
Temperature codeT4 for North America, T4 for IEC
Source1783-TD002D-EN-P, May 2023

The fiber tap is the part that lets a device sit in a drive cabinet at the far end of a line without a copper run back to the switch. Two fiber ports, 260 mA of 24V load, and a link budget that is stated in decibels rather than in distance, which is the honest way to describe an optical link because the connectors and splices consume the budget before the cable does.

Read the two budgets together: 12.8 dB on 62.5/125 micron fiber and 9.3 dB on 50/125 micron. The larger core wins here because the launch into graded index multimode is more efficient, and a layout that quotes 2 km on 50/125 fiber without subtracting connector loss is a layout that will not link.

Two attributes in the table decide more installations than the port count does: the supply range, because a 24V nominal device with a 20.4V lower limit behaves differently from one that accepts 12V, and the surrounding air limit, because a switch rated at 60 degrees C in a cabinet designed for 70 degrees C is a thermal problem rather than a network problem.

The emission class is CISPR 11 Class A, which is an industrial environment statement. Mounting one of these in a light industrial or residential panel can require additional filtering, and that is a compliance question rather than a performance one, so it belongs in the quotation stage.

The distance an SFP reaches is a property of the optic and the fiber, not of the switch. Multimode runs to a few hundred meters, singlemode runs to kilometers, and the budget has to cover connectors and splices, so the link loss calculation belongs in the same document as the port list.

An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.

On 1783-ETAP2F conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.

Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.

On 1783-ETAP2F the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.

Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.

Temperature is quoted at the surrounding air rather than at the board, and the 60 degrees C ceiling on the managed units is lower than the 70 degrees C that the FLEX Ex and most I/O families allow. A cabinet that was designed around an I/O module rating will need a thermal review before a switch is added at the top of the rail.

A switch that has been in a cabinet for eight years, 1783-ETAP2F among them, is usually still electrically sound and functionally obsolete. The practical question at replacement time is whether the firmware can still be managed by the current tool, and a unit that cannot be reached by the engineering software is a unit that will be replaced on failure rather than on schedule.

A managed switch adds the diagnostics that make a network debuggable: port level counters, spanning tree, and in the Stratix range a Device Level Ring that survives a single cable break. The catalog suffix tells you whether that firmware is present, and a Lite unit is not upgradeable into a Full one by flashing it. For 1783-ETAP2F the suffix is the only reliable statement of which firmware set ships.

Every one of these units, 1783-ETAP2F included, is open style, which means it belongs in an enclosure with a pollution degree 2 environment. The IP30 rating protects against fingers and tools, not against water, and a switch mounted on an open panel in a wet area is a warranty claim waiting to happen.

Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.

Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.

For 1783-ETAP2F the NAT variants exist for the machine builder who must hand over a cell with a fixed internal address scheme. A configurable NAT router lets the same internal IP plan be reused on every machine while the plant side sees a different address, which removes an entire class of commissioning arguments.

Subtract connector and splice loss from the published budget before quoting a distance, confirm the LC connector loss figure on the patch cords, and keep the pair of taps inside one campaign rather than mixed with copper taps.

The Allen-Bradley 1783 network switches category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)