Product Details:
Payment & Shipping Terms:
|
1771-IAN is a 32-point input module for the 1771 I/O chassis used by PLC-5 and PLC-2 processors. A 32-point card is the density answer for a rack that is already full: it halves the number of input modules, but it also halves the number of spare slots available for a failed card.
Field connections land on the 1771-WA wiring arm, the 10-terminal arm that swings up to the module so the arm can stay wired while the module is swapped.
Catalog number |
1771-IAN |
Product type |
32-point input module |
Number of inputs |
32 |
Input signal |
Not published |
Module series |
C |
1771 chassis compatibility |
Series B chassis, 1-slot restricted, 2-slot not compatible |
Lifecycle status |
Discontinued |
Discontinued date |
31 December 2013 |
Replacement category |
Engineering Replacement |
UPC |
Not published |
Country of origin |
Not published |
Field wiring arm |
1771-WA, 10 terminal |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1771-TD180 (module specifications) and 1785-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
1771-IAN is a 32-point input module for the 1771 I/O chassis used by PLC-5 and PLC-2 processors. A 32-point card is the density answer for a rack that is already full: it halves the number of input modules, but it also halves the number of spare slots available for a failed card.
The slot it occupies is one 1771 slot, and the input image it claims is fixed by the module series: 32. That number decides how much of the processor input table the rack consumes, not how many wires the panel brings in.
Signal level is Not published. Nothing in the module is software configurable, so the field device has to match the printed range before the module is ordered.
Field connections land on the 1771-WA wiring arm, the 10-terminal arm that swings up to the module so the arm can stay wired while the module is swapped.
Keying bands in the chassis connector must line up with the slots on the module board. 1771 chassis are keyed per module type precisely so a 120 V AC module cannot be pushed into a slot wired for a 24 V DC module.
Backplane current comes from the chassis supply, so the load of every module in the rack has to be added up before a rack is repopulated with these cards.
The 32-point series C cards sit under 1-slot addressing restrictions in the published compatibility table, so the chassis addressing mode has to be checked first.
Chassis compatibility is published per module series: Series B chassis, 1-slot restricted, 2-slot not compatible. Series A modules fit the superseded 1771-A1, -A2 and -A4 chassis as well as the current A1B to A4B and AM1/AM2 chassis.
Some 32-point and isolated cards can only be placed under 1-slot or 2-slot addressing rules, so the addressing mode of the chassis has to be confirmed before a mixed rack is built.
Rockwell lists 1771-IAN as Discontinued, replacement category Engineering Replacement.
The published discontinued date is 31 December 2013.
The family replacement path is a 1756 or 1794 migration, which means the field wiring, the wiring arms and the addressing scheme all change. Buying the same catalog number is usually cheaper than re-terminating a panel.
Ask for a photo of the label side and the wiring arm. A module removed without its arm has to be re-keyed and re-wired, which is where most of the cost of a used card actually sits.
Check the module series letter against the chassis series: an A-series card in an A1B chassis works, but the reverse combination is what produces "module not recognised" faults.
These are static-sensitive cards. A unit shipped loose without conductive foam is a risk, whatever the price.
How many inputs does 1771-IAN have?
32, on the published 1771 data sheet.
What input signal does 1771-IAN accept?
Not published.
Which 1771 chassis will accept 1771-IAN?
Series B chassis, 1-slot restricted, 2-slot not compatible.
Is 1771-IAN still available from Rockwell?
No. It is listed as Discontinued with replacement category Engineering Replacement.
What is the discontinued date of 1771-IAN?
31 December 2013.