Product Details:
Payment & Shipping Terms:
|
1783-EMS04T is the earliest and smallest of these managed lines, four ports in a compact housing — 4 ports.
Its replacement is the 1783-LMS5, a different platform entirely. A 6000 in a running panel is therefore a migration decision rather than a straight swap, and the firmware and AOP versions travel with it.
| 1783-BMS20CL | Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP | IN STOCK |
| 1783-BMS20CGP | Stratix 5700, 20 ports, gigabit combo | IN STOCK |
| 1783-BMS20CGL | Stratix 5700, 20 ports, gigabit combo, Lite firmware | IN STOCK |
| 1783-BMS20CGPK | Stratix 5700, 20 ports, gigabit combo, kit | IN STOCK |
| 1783-BMS06TA | Stratix 5700, 6 copper ports | IN STOCK |
| 1783-BMS06TL | Stratix 5700, 6 copper ports, Lite firmware | IN STOCK |
| 1783-BMS06TGA | Stratix 5700, 4 copper + 2 gigabit copper | IN STOCK |
| 1783-BMS06SA | Stratix 5700, 4 copper + 2 SFP | IN STOCK |
| 1783-BMS06SL | Stratix 5700, 4 copper + 2 SFP, Lite firmware | IN STOCK |
| 1783-BMS06SGA | Stratix 5700, 4 copper + 2 gigabit SFP | IN STOCK |
| 1783-BMS06SGL | Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware | IN STOCK |
| 1783-MS06T | Stratix 8000, 6 port chassis | IN STOCK |
| 1783-MS10T | Stratix 8000, 10 port chassis | IN STOCK |
| 1783-RMS06T | Stratix 8300, 6 port layer 3 | IN STOCK |
| 1783-RMS10T | Stratix 8300, 10 port layer 3 | IN STOCK |
| 1783-EMS04T | Stratix 6000, 4 port managed | IN STOCK |
| 1783-MX08T | Stratix 8000 copper 8 port expansion | IN STOCK |
| 1783-MX08F | Stratix 8000 fibre 8 port expansion | IN STOCK |
| 1783-MCF | Stratix 8000 CompactFlash spare card | IN STOCK |
| 1783-RMCF | Stratix 8300 CompactFlash spare card | IN STOCK |
| 1783-ETAP | EtherNet/IP tap, 3 copper ports | IN STOCK |
| 1783-ETAP2F | EtherNet/IP tap, 1 copper + 2 fibre | IN STOCK |
| 1783-SFP100FX | 100FX multimode SFP, 2 km | IN STOCK |
| 1783-SFP100LX | 100LX singlemode SFP, 10 km | IN STOCK |
| 1783-SFP1GSX | 1000SX multimode SFP, 550 m | IN STOCK |
| 1783-SFP1GLX | 1000LX singlemode SFP, 10 km | IN STOCK |
| 1783-US8T | Stratix 2000, 8 copper ports, unmanaged | IN STOCK |
| 1783-US03T01F | Stratix 2000, 3 copper + 1 fibre, unmanaged | IN STOCK |
Catalog number |
1783-EMS04T |
Product family |
Stratix 6000 4 port managed switch |
Total ports |
4 ports |
Copper ports |
4 * 10/100 RJ45 |
SFP ports |
None |
Combination ports |
None |
Power input |
Not published |
Power consumption |
Not published |
Weight |
Not published for this catalog number |
Mounting |
Panel mount |
Firmware type |
Not published for this catalog number |
UPC |
612598718481 |
Lifecycle status |
Discontinued May 31, 2019 |
Replacement category |
Engineering Replacement |
Replacement product |
1783-LMS5 |
Publication |
1783-UM011 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Copper: 4 * 10/100 RJ45. SFP: None. Combination: None.
A combination port accepts either an RJ45 module or a Mini-GBIC, so the copper count and the fibre count cannot both be taken at face value on a unit where both are populated.
Not published; Not published; Panel mount.
An alarm relay rated 1 A at 30V dc switches a panel lamp or a PLC input when the switch loses a supply or a monitored condition. That contact is often the only thing an operator sees when the network fails.
Four managed ports in a compact housing covered the case where a machine needed segmentation and nothing more.
Managed switching inside a panel is about segmentation and diagnostics, not throughput. A cell/zone layout with IGMP snooping is what stops multicast I/O traffic from flooding every port in the cabinet.
Discontinued May 31, 2019, replacement category Engineering Replacement, replacement product 1783-LMS5.
Existing units stay in service for years after a switch is retired. The practical questions are spare hardware and configuration backup — a replacement switch with no saved configuration is not a spare.
Ask for the firmware revision, the configuration export and a photograph of the label. On a managed switch these three matter more than cosmetic condition.
A unit pulled from a working line with a documented configuration is worth more than an unconfigured identical unit, and should be priced that way.
How many ports does 1783-EMS04T have?
4 ports
What power does 1783-EMS04T need?
Not published
Is 1783-EMS04T still available from Rockwell?
No. Discontinued May 31, 2019; replacement category Engineering Replacement.
What replaces 1783-EMS04T?
1783-LMS5
What is 1783-EMS04T used for?
Stratix 6000 4 port managed switch — a managed Ethernet switch for a control network.
1783-EMS04T is part of the Allen-Bradley Stratix industrial Ethernet range, described here from the Rockwell technical data and installation instructions so that the supply, the isolation and the temperature limits on the page are the ones an integrator can actually design against.
| Specification | Value |
|---|---|
| Ports | 4 RJ45 10/100 full or half duplex ports |
| Power input | 100 mA at 24V DC, 12 to 48V DC, Class 2 or SELV, inrush 2.2 A maximum |
| Power dissipation | 2.6 W maximum, thermal dissipation 24.6 BTU per hour at 60 degrees C |
| Isolation | 50V continuous basic insulation, power to ground and power to network; no isolation between network channels; routine tested 707V AC for 1 s |
| Protocols | TCP/IP, EtherNet/IP, Telnet, HTTP, DHCP, BOOTP, FTP, IGMP, SMTP |
| Switch features | IGMP snooping, IGMP query V1 and V2, DHCP server, BOOTP server, QoS, port mirroring |
| EtherNet/IP features | MAC ID management, bandwidth alarming, port control, link status, scaled bandwidth information, connections active |
| Indicators | 8 port indicators, 2 status indicators |
| Operating temperature | 0 to 60 degrees C, surrounding air maximum 60 degrees C |
| Wire size | Power 0.33 to 3.3 mm2 (22 to 12 AWG), ground 3.3 mm2 (12 AWG), both rated 75 degrees C |
| Terminal torque | 1.36 N m (12 in lb) on power and ground terminals |
| Rating | IP20, open style, T4 temperature code, 15 g operating and 30 g nonoperating shock |
| Source | 1783-TD002D-EN-P, May 2023 |
This is the small managed switch in the range, and the two facts that decide whether it fits are the 1.36 N m terminal torque, which is far higher than the other models, and the 0 degree C lower limit on the operating temperature. A cabinet that is designed for -40 degrees C at the top of the range cannot use this part at the bottom of the cabinet, and the difference is easy to miss because the model number looks like the rest of the family.
The feature list is generous for four ports: IGMP snooping and query, a DHCP and BOOTP server, QoS and port mirroring, plus EtherNet/IP diagnostics including bandwidth alarming and port control. In a small cell that is the difference between a network an engineer can diagnose from the controller and a network that has to be probed with a laptop.
Two attributes in the table decide more installations than the port count does: the supply range, because a 24V nominal device with a 20.4V lower limit behaves differently from one that accepts 12V, and the surrounding air limit, because a switch rated at 60 degrees C in a cabinet designed for 70 degrees C is a thermal problem rather than a network problem.
An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.
On 1783-EMS04T conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.
Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.
On 1783-EMS04T the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.
Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.
Temperature is quoted at the surrounding air rather than at the board, and the 60 degrees C ceiling on the managed units is lower than the 70 degrees C that the FLEX Ex and most I/O families allow. A cabinet that was designed around an I/O module rating will need a thermal review before a switch is added at the top of the rail.
A switch that has been in a cabinet for eight years is usually still electrically sound and functionally obsolete. The practical question at replacement time is whether the firmware can still be managed by the current tool, and a unit that cannot be reached by the engineering software is a unit that will be replaced on failure rather than on schedule.
A managed switch adds the diagnostics that make a network debuggable: port level counters, spanning tree, and in the Stratix range a Device Level Ring that survives a single cable break. The catalog suffix tells you whether that firmware is present, and a Lite unit is not upgradeable into a Full one by flashing it. For 1783-EMS04T the suffix is the only reliable statement of which firmware set ships.
Every one of these units, 1783-EMS04T included, is open style, which means it belongs in an enclosure with a pollution degree 2 environment. The IP30 rating protects against fingers and tools, not against water, and a switch mounted on an open panel in a wet area is a warranty claim waiting to happen.
Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.
Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.
For 1783-EMS04T the NAT variants exist for the machine builder who must hand over a cell with a fixed internal address scheme. A configurable NAT router lets the same internal IP plan be reused on every machine while the plant side sees a different address, which removes an entire class of commissioning arguments.
Spare parts strategy on a switch is driven by firmware, not by hardware. A Lite spare cannot replace a Full unit in a ring that depends on CIP Sync, so the stocking list should carry the suffix rather than the base number, and the label on the failed unit is the authority.
In a plant network the switch, 1783-EMS04T included, is usually the part that gets blamed last and fails first, because it sits between a drive that trips and a controller that logs nothing. Keeping the port count, the supply range and the temperature rating on the page means a maintenance engineer can replace a unit without opening a drawing set.
Check the 0 degrees C lower limit against the cabinet specification first, torque the terminals to 1.36 N m, and use the IGMP and mirroring features rather than adding a second diagnostic switch.
This part sits in the Allen-Bradley 1783 network switches category, with the other models and spare parts listed alongside it.