The 1756-A13 (also written 1756A13) is the 13-slot ControlLogix chassis, published with a minimum enclosure of 60.9 x 76.2 x 20.3 cm (24 x 30 x 8 in.) and an operating range of 0...60 °C (32...140 °F). It sits between the 10-slot and 17-slot racks and is the usual answer when a line needs more than ten module positions but a 91.4 cm-wide enclosure is not available.
The chassis carries the backplane only. Power is a separately ordered supply — a single 1756-PA75 or 1756-PB75, or the redundant pair on a /B or /C chassis through a 1756-PSCA2 adapter.
Its distinguishing published attribute is the temperature rating: 0...60 °C is stated on the product record, and the chassis is convection cooled, so the rating depends on the enclosure actually delivering airflow. A sealed cabinet with no convection path will not reach the top of that range.
Published record: UPC 612598129287, active lifecycle, country of origin United States, one year warranty, drawings in 2-D PDF, DXF and 3-D STEP, installation instructions in the ControlLogix system user manual 1756-UM001, selection guide 1756-SG001.
1756-A4 |
4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm, UPC 612598129300 |
In stock |
1756-A7 |
7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm, UPC 612598129317 |
In stock |
1756-A10 |
10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm, UPC 612598129270 |
In stock |
1756-A13 |
13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, UPC 612598129287 |
In stock |
1756-A17 |
17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, UPC 612598129294 |
In stock |
Application |
Chassis / backplane |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-A13 |
Communication |
— |
Display |
— |
Enclosure |
Open chassis, convection cooled |
Interface |
Backplane |
Mounting |
Panel, bracket supplied |
Number Of Channels |
— |
Standard |
CE, UL, cUL |
Sub Brand |
ControlLogix |
Type |
Chassis |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
A 13-slot rack is typical of a line controller cabinet: one chassis carrying the controller, the network modules and the I/O for a whole machine, with the 60.9 cm height fitting a 24 x 30 in. enclosure.
It also suits a design that must keep all I/O in one chassis for scan-time reasons — cross-rack communication is removed from the I/O path entirely.
With the 0...60 °C rating published, this chassis is the family member most often specified for plants that run warm cabinets, provided the convection path is designed in rather than assumed.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 0...60 °C needs airflow | The rating is an ambient range, not a promise inside a closed box. Convection cooling means the enclosure volume and venting decide the real limit. |
| Check 3 | 60.9 x 76.2 cm footprint | Taller than the 10-slot rack (50.8 cm) and the same width. It is the size that fits a 24 x 30 in. enclosure minimum. |
| Check 4 | Supply current budget | Add the published backplane currents of every module and compare with the supply. A 13-slot rack can exceed a single supply's rating with a dense mix. |
| Check 5 | Series and pairing | /B for the AC redundant pair, /C for the DC pair; a standard chassis for a single supply (1756-IN620). |
Slot and supply compatibility per Rockwell publication 1756-IN620 (ControlLogix Redundant Power Supply installation instructions) and 1756-UM001 (ControlLogix system user manual, chassis installation) and 1756-IN050.
Down one step is 1756-A10 (10 slots, 50.8 x 76.2 cm); up one step is 1756-A17 (17 slots, 76.2 x 91.4 cm, 0...60 °C).
The 10-slot and 13-slot racks differ in height, not width — a panel already cut for 76.2 cm of width gains three slots by growing 10.1 cm taller.
Supplies, adapter and cables are common across the family; only the rack and the slot drawing change.
What is the 1756-A13?
A 13-slot ControlLogix chassis, convection cooled, minimum enclosure 60.9 x 76.2 x 20.3 cm (24 x 30 x 8 in.), 0...60 °C published.
Does it ship with a power supply?
No. Order 1756-PA75 or 1756-PB75 for a single supply, or the redundant pair with 1756-PSCA2 on a /B or /C chassis.
What is the temperature rating?
0...60 °C (32...140 °F) as published, which depends on the enclosure providing the convection path.
How many modules fit?
Thirteen, with the power supply in the leftmost position and the controller in one of the slots.
Which series accepts redundancy?
/B for the AC redundant pair and /C for the DC pair, per 1756-IN620.
Is the rack field-expandable?
No. Slot count is fixed by the backplane; a larger design needs a different chassis.
Where is it made?
Country of origin United States as published; UPC 612598129287.
What drawings exist?
2-D PDF, DXF and a 3-D STEP model, plus installation instructions in the ControlLogix system user manual 1756-UM001.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-A13. Values re-checked 15 November 2026.