logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-A13 / 1756A13

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-A13 / 1756A13

China Allen Bradley PLC 1756-A13 / 1756A13 supplier
Allen Bradley PLC 1756-A13 / 1756A13 supplier Allen Bradley PLC 1756-A13 / 1756A13 supplier Allen Bradley PLC 1756-A13 / 1756A13 supplier Allen Bradley PLC 1756-A13 / 1756A13 supplier Allen Bradley PLC 1756-A13 / 1756A13 supplier

Large Image :  Allen Bradley PLC 1756-A13 / 1756A13

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-A13 / 1756A13

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $405.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 3 PCS
Detailed Product Description

1756-A13 technical data PDF download 1756-A13 ControlLogix 13 Slot Chassis | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-A13 (also written 1756A13) is the 13-slot ControlLogix chassis, published with a minimum enclosure of 60.9 x 76.2 x 20.3 cm (24 x 30 x 8 in.) and an operating range of 0...60 °C (32...140 °F). It sits between the 10-slot and 17-slot racks and is the usual answer when a line needs more than ten module positions but a 91.4 cm-wide enclosure is not available.

The chassis carries the backplane only. Power is a separately ordered supply — a single 1756-PA75 or 1756-PB75, or the redundant pair on a /B or /C chassis through a 1756-PSCA2 adapter.

Its distinguishing published attribute is the temperature rating: 0...60 °C is stated on the product record, and the chassis is convection cooled, so the rating depends on the enclosure actually delivering airflow. A sealed cabinet with no convection path will not reach the top of that range.

Published record: UPC 612598129287, active lifecycle, country of origin United States, one year warranty, drawings in 2-D PDF, DXF and 3-D STEP, installation instructions in the ControlLogix system user manual 1756-UM001, selection guide 1756-SG001.

1756-A4
4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm, UPC 612598129300
In stock
1756-A7
7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm, UPC 612598129317
In stock
1756-A10
10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm, UPC 612598129270
In stock
1756-A13
13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, UPC 612598129287
In stock
1756-A17
17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, UPC 612598129294
In stock

 Application
 Chassis / backplane
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-A13
 Communication
 —
 Display
 —
 Enclosure
 Open chassis, convection cooled
 Interface
 Backplane
 Mounting
 Panel, bracket supplied
 Number Of Channels
 —
 Standard
 CE, UL, cUL
 Sub Brand
 ControlLogix
 Type
 Chassis
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-A13 chassis view 1 product photograph 1756-A13 chassis view 2 product photograph 1756-A13 chassis view 3 product photograph

Where the module sits in a typical system

A 13-slot rack is typical of a line controller cabinet: one chassis carrying the controller, the network modules and the I/O for a whole machine, with the 60.9 cm height fitting a 24 x 30 in. enclosure.

It also suits a design that must keep all I/O in one chassis for scan-time reasons — cross-rack communication is removed from the I/O path entirely.

With the 0...60 °C rating published, this chassis is the family member most often specified for plants that run warm cabinets, provided the convection path is designed in rather than assumed.

Commissioning in five steps

  1. Confirm the chassis series against the supply: a /B chassis takes the AC redundant pair, a /C chassis takes the DC pair, and a standard chassis takes one non-redundant supply. The compatibility table in 1756-IN620 is the authority for this.
  2. Mount the chassis on the panel using the bracket the chassis ships with, and leave the convection path open — the published minimum enclosure size is a volume requirement, not a clearance allowance.
  3. Install the power supply, then verify the backplane voltages at the supply terminals before any module is inserted. A wiring error found with an empty chassis costs a fuse; found with a loaded chassis it costs modules.
  4. Insert modules with the chassis de-energised, then check that every module seats flush. A module that stops half way leaves its backplane connector open.
  5. Record the slot assignment on the drawing. ControlLogix allows the controller and communication modules to be placed in the slots the design needs, so the drawing rather than convention is what a later technician will follow.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  0...60 °C needs airflow  The rating is an ambient range, not a promise inside a closed box. Convection cooling means the enclosure volume and venting decide the real limit.
 Check 3  60.9 x 76.2 cm footprint  Taller than the 10-slot rack (50.8 cm) and the same width. It is the size that fits a 24 x 30 in. enclosure minimum.
 Check 4  Supply current budget  Add the published backplane currents of every module and compare with the supply. A 13-slot rack can exceed a single supply's rating with a dense mix.
 Check 5  Series and pairing  /B for the AC redundant pair, /C for the DC pair; a standard chassis for a single supply (1756-IN620).

Slot and supply compatibility per Rockwell publication 1756-IN620 (ControlLogix Redundant Power Supply installation instructions) and 1756-UM001 (ControlLogix system user manual, chassis installation) and 1756-IN050.

Sizing the rack and upgrading the slot count

Down one step is 1756-A10 (10 slots, 50.8 x 76.2 cm); up one step is 1756-A17 (17 slots, 76.2 x 91.4 cm, 0...60 °C).

The 10-slot and 13-slot racks differ in height, not width — a panel already cut for 76.2 cm of width gains three slots by growing 10.1 cm taller.

Supplies, adapter and cables are common across the family; only the rack and the slot drawing change.

Which ControlLogix EtherNet/IP module to specify

  • 1756-A4 — 4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm; the smallest enclosure footprint of the family.
  • 1756-A7 — 7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm; the size most machine-level panels are built around.
  • 1756-A10 — 10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm.
  • 1756-A13 — 13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, 0...60 °C published.
  • 1756-A17 — 17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, 0...60 °C published.
  • Series suffix matters — /B chassis take the AC redundant pair (1756-PA75R x2 + 1756-PSCA2 + 1756-CPR2 x2); /C chassis take the DC redundant pair (1756-PB75R x2 + the same adapter and cables).
  • 1756-PA75 / 1756-PB75 — the single supplies used when redundancy is not required; ordered separately from the chassis.

FAQ — 1756-A13 ControlLogix 13 Slot Chassis | Rockwell

What is the 1756-A13?

A 13-slot ControlLogix chassis, convection cooled, minimum enclosure 60.9 x 76.2 x 20.3 cm (24 x 30 x 8 in.), 0...60 °C published.

Does it ship with a power supply?

No. Order 1756-PA75 or 1756-PB75 for a single supply, or the redundant pair with 1756-PSCA2 on a /B or /C chassis.

What is the temperature rating?

0...60 °C (32...140 °F) as published, which depends on the enclosure providing the convection path.

How many modules fit?

Thirteen, with the power supply in the leftmost position and the controller in one of the slots.

Which series accepts redundancy?

/B for the AC redundant pair and /C for the DC pair, per 1756-IN620.

Is the rack field-expandable?

No. Slot count is fixed by the backplane; a larger design needs a different chassis.

Where is it made?

Country of origin United States as published; UPC 612598129287.

What drawings exist?

2-D PDF, DXF and a 3-D STEP model, plus installation instructions in the ControlLogix system user manual 1756-UM001.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-A13. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda