Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-DMA31 / 1756DMA31

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $3252.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1756-DMA31 technical data PDF download 1756-DMA31 / 1756DMA31 Single-Axis Drive Control Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-DMA31 is the single-axis drive control module. Rockwell's catalogue description reads 1-AXIS DRV CTRL RE SA31001, and the module is discontinued as of 18 April 2022 with Engineering Replacement as the replacement category.

It is the backplane interface to an axis, not the drive itself: Studio 5000 defines its data types as DMA31_VELOCITYCONTROL and DMA31_POSITIONCONTROL, matching the two communication formats it supports.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Motion control, single axis
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-DMA31
 Catalog Description
 1-AXIS DRV CTRL RE SA31001 - 1-AXIS DRV CTRL
 Function
 Single-axis drive control module in a ControlLogix chassis
 Programming Data Types
 DMA31_VELOCITYCONTROL, DMA31_POSITIONCONTROL
 Communication Formats
 Velocity Control, Position Control
 Backplane Current
 Not published on the Rockwell product page
 Power Dissipation
 Not published on the Rockwell product page
 Lifecycle Status
 Discontinued
 Discontinued Date
 18 April 2022
 Replacement Category
 Engineering Replacement
 Certification
 CE, certified as of 14 March 2023

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-DMA31 single-axis drive control module product photograph 1756-DMA31, second view product photograph 1756-DMA31, third view product photograph

Where the module sits between controller and drive

The DMA31 is a single-axis drive control module. Rockwell's own catalogue description is 1-AXIS DRV CTRL RE SA31001, and Studio 5000 documents its module-defined data types as DMA31_VELOCITYCONTROL and DMA31_POSITIONCONTROL, which is what fixes its role: the module sits in the ControlLogix chassis and presents an axis to the controller.

That role is worth stating plainly, because the module is often mistaken for the drive. The drive and its power stage are separate hardware; the module is the backplane interface that the controller writes motion commands to and reads axis status from. When an axis faults, the first question is which side of that boundary the fault lives on, and the module's data types are what tell you which commands were in flight.

The two communication formats are the practical detail. Velocity Control sends a velocity command per update; Position Control sends a position command. They produce different data layouts, so the module profile and the axis configuration must agree. A configuration written for one format and downloaded against a module set up for the other will not simply misbehave — it will not line up at all.

Lifecycle is closed: discontinued on 18 April 2022, with Engineering Replacement as the replacement category. That category is the meaningful signal for a maintenance engineer: the replacement is not a drop-in board, it is an engineering change that has to be designed, because the motion architecture around it has moved on.

No backplane current or dissipation figure is published on the Rockwell product page for this item. Third-party listings quote 1.35 A at 5 V DC, but a distributor figure is not the manufacturer's specification, so it is not carried here.

Where a machine still runs this module, the useful work before failure is documentation: the axis configuration, the communication format, the drive parameters and the firmware revision. Those four items decide whether the machine can be brought back with a spare module or whether it needs a motion redesign at the next outage.

Commissioning in three checks

  1. Read the axis configuration, not just the module status; a drive fault and a module fault are different events.
  2. Plan the replacement as a motion architecture change, not a like-for-like board swap.
  3. Record the module's communication format before removal; velocity and position control use different data types.

Axis faults and what they mean

The module has no motion diagnostics of its own beyond the axis status it returns; a fault on the drive side and a fault on the module side are separated by reading the axis status and the drive status together.

 Indicator  State  Meaning and first action
 Module not accepted in the chassis  —  Discontinued in 2022 with Engineering Replacement as the category; a replacement needs a new module profile, not a swap.

Facts on this page come only from the Rockwell publications named above; anything they do not state is marked as not published and 1756-IN050.

Replacing this item

Record the installed configuration before removal so the replacement can be mapped against it.

Verify the replacement category against the current Rockwell product page rather than against a distributor list.

Keep one spare of the original where the machine cannot be re-commissioned quickly.

Which part to specify instead

  • 1756-DMA31 — single-axis drive control, discontinued 2022.
  • 1756-DMD30 / DMF30 — drive modules for the same generation of axis control.
  • 1756-M08SE / M16SE — SERCOS interface modules for multi-axis systems.
  • 1756-M02AE / M02AS — analog motion modules where a simple axis is all that is needed.

FAQ — 1756-DMA31 / 1756DMA31 Single-Axis Drive Control Module

What is the 1756-DMA31?

A single-axis drive control module for the ControlLogix chassis.

What does its catalogue description say?

1-AXIS DRV CTRL RE SA31001 - 1-AXIS DRV CTRL.

Is it a drive?

No, it is the backplane interface to the drive; the power stage is separate hardware.

What communication formats does it use?

Velocity Control and Position Control.

When was it discontinued?

18 April 2022.

What is the replacement category?

Engineering Replacement.

What certification does it carry?

CE, certified as of 14 March 2023.

What is its backplane current?

Not published on the Rockwell product page.


Data sources. Technical values on this page come from Rockwell publications Rockwell product data (catalog description, discontinued 18 April 2022, Engineering Replacement, CE) and Studio 5000 Logix Designer documentation for the 1756-DMA31 module-defined data types and communication formats and the manufacturer's product page for 1756-DMA31. Values re-checked 16 November 2026.