The 1756-CP3 (also written 1756CP3) is the Logix family RS-232 programmer cable — Rockwell titles it Logix5000 RS232 Programmer Cable and publishes it as an active, mature product. It is the cable that connects a programming terminal to a Logix controller's serial port, and the same cable is named in 1756-IN587 as the connection between each 1756-DH485 channel and a 1761-NET-AIC converter.
That second use is the one most people miss. A 1756-DH485 module has no direct DH-485 terminal block: each of its two channels is cabled to an AIC+ converter with a 1756-CP3, and the converter then connects to the DH-485 trunk. Without the cable, the module is installed but not on the network.
Mechanically the cable is not symmetrical. In the 1756-DH485 procedure the right-angle connector end goes to the 1761-NET-AIC converter and the straight end to the module, so the cable's shape has to match the space behind the panel, not just the part number.
Published record: UPC 612598173785, country of origin China, function Logix RS-232 programming cable, temperature rating 0...60 °C (32...140 °F), estimated lead time 5 days, one year warranty; documents 1756-IN046 for installation, 1756-TD002 and the selection guide 1756-SG001.
1756-CP3 | Logix RS-232 programmer cable, one per DH-485 channel, active mature, UPC 612598173785 | In stock |
1756-DH485 | DH-485 communications module, 2 channels, 850 mA at 5.1 V DC, UPC per Rockwell record | In stock |
1761-NET-AIC | AIC+ converter required per DH-485 channel — not a 1756 item | In stock |
Application | DH-485 messaging / serial programming |
Brand Name | Rockwell (Rockwell) |
Cat Num | 1756-CP3 |
Communication | RS-232 |
Display | — |
Enclosure | None (open-style) |
Interface | RS-232, D-shell to mini-DIN |
Mounting | Field cable |
Number Of Channels | 1 |
Standard | CE, UL, CSA |
Sub Brand | ControlLogix |
Type | Cable |
UNSPSC | — |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN587 (DH-485 module installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The cable's main job today is maintenance: recovering a controller whose Ethernet port is not reachable, or commissioning a rack before the network is live. It is kept in the tool case, not installed permanently.
Its second job is legacy integration. A plant still carrying SLC 500 or MicroLogix devices on DH-485 needs a 1756-DH485 module, an AIC+ per channel and a CP3 per channel — three catalogue lines per channel, which is why DH-485 integration quotes surprise people.
Because the cable is passive, the failure modes are mechanical: a bent pin, a worn connector after years of field use, or a cable left coiled in a hot cabinet. Keep a spare; it costs little and it is the fastest way to rule out the cable when a serial link stops working.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | Connector orientation | Right-angle end to the 1761-NET-AIC, straight end to the module (1756-IN587). Reversing it changes the clearance behind the panel and can strain the module port. |
| Check 3 | Serial port on the terminal | The cable is RS-232. A modern laptop without a serial port needs a USB-to-serial adapter, and that adapter is a second failure point to test before blaming the controller. |
| Check 4 | Active mature, not obsolete | Lifecycle is published as active, mature — the part is available, but the serial-programming route itself belongs to older practice. Design new networks on EtherNet/IP. |
| Check 5 | One cable per converter | An AIC+ serves one channel. Two channels, two converters, two cables. |
Specifications and wiring per Rockwell publication 1756-IN587 (ControlLogix DH-485 Communications Module installation instructions); product attributes per the Rockwell product record and 1756-IN050.
There is no substitute part in the ControlLogix catalogue — the cable is named as the connection in the DH-485 installation instructions, and the AIC+ procedure depends on it.
For programming, the modern route is the controller's Ethernet port and no cable at all. The CP3 remains the fallback for controllers without a reachable network port.
For new DH-485 integration, the network itself is the thing to question: 1756-CN2 and 1756-EN2T modules on ControlNet or EtherNet/IP remove the converter, the cable and the second network from the design.
What is the 1756-CP3?
The Logix family RS-232 programmer cable, published by Rockwell as the Logix5000 RS232 Programmer Cable.
What is it used for?
Connecting a programming terminal to a Logix controller's serial port, and connecting each 1756-DH485 channel to a 1761-NET-AIC converter.
Does a 1756-DH485 need one?
Yes — one per channel. 1756-IN587 directs each channel to a 1761-NET-AIC converter through a 1756-CP3 cable.
Which end goes where?
Right-angle connector to the 1761-NET-AIC converter, straight connector to the module, as printed in 1756-IN587.
Is it still produced?
Lifecycle is active, mature: available, with a published 5 day lead time and one year warranty.
What is the temperature rating?
0...60 °C (32...140 °F) as published.
Where is it made, and what is the UPC?
Country of origin China, UPC 612598173785.
What documents cover it?
Installation instructions 1756-IN046, technical data 1756-TD002 and selection guide 1756-SG001.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-CP3. Values re-checked 15 November 2026.