Allen Bradley PLC 1756-CP3 / 1756CP3

China Allen Bradley PLC 1756-CP3 / 1756CP3 supplier
Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier Allen Bradley PLC 1756-CP3 / 1756CP3 supplier

Large Image :  Allen Bradley PLC 1756-CP3 / 1756CP3

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CP3 / 1756CP3

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $46.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10PCS
Detailed Product Description


1756-CP3 technical data PDF download 1756-CP3 Logix RS232 Programmer Cable | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CP3 (also written 1756CP3) is the Logix family RS-232 programmer cable — Rockwell titles it Logix5000 RS232 Programmer Cable and publishes it as an active, mature product. It is the cable that connects a programming terminal to a Logix controller's serial port, and the same cable is named in 1756-IN587 as the connection between each 1756-DH485 channel and a 1761-NET-AIC converter.

That second use is the one most people miss. A 1756-DH485 module has no direct DH-485 terminal block: each of its two channels is cabled to an AIC+ converter with a 1756-CP3, and the converter then connects to the DH-485 trunk. Without the cable, the module is installed but not on the network.

Mechanically the cable is not symmetrical. In the 1756-DH485 procedure the right-angle connector end goes to the 1761-NET-AIC converter and the straight end to the module, so the cable's shape has to match the space behind the panel, not just the part number.

Published record: UPC 612598173785, country of origin China, function Logix RS-232 programming cable, temperature rating 0...60 °C (32...140 °F), estimated lead time 5 days, one year warranty; documents 1756-IN046 for installation, 1756-TD002 and the selection guide 1756-SG001.

1756-CP3
Logix RS-232 programmer cable, one per DH-485 channel, active mature, UPC 612598173785
In stock
1756-DH485
DH-485 communications module, 2 channels, 850 mA at 5.1 V DC, UPC per Rockwell record
In stock
1761-NET-AIC
AIC+ converter required per DH-485 channel — not a 1756 item
In stock

 Application
 DH-485 messaging / serial programming
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CP3
 Communication
 RS-232
 Display
 —
 Enclosure
 None (open-style)
 Interface
 RS-232, D-shell to mini-DIN
 Mounting
 Field cable
 Number Of Channels
 1
 Standard
 CE, UL, CSA
 Sub Brand
 ControlLogix
 Type
 Cable
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN587 (DH-485 module installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CP3 programmer cable product photograph 1756-CP3 connector detail product photograph 1756-CP3 cable view product photograph

Where the module sits in a typical system

The cable's main job today is maintenance: recovering a controller whose Ethernet port is not reachable, or commissioning a rack before the network is live. It is kept in the tool case, not installed permanently.

Its second job is legacy integration. A plant still carrying SLC 500 or MicroLogix devices on DH-485 needs a 1756-DH485 module, an AIC+ per channel and a CP3 per channel — three catalogue lines per channel, which is why DH-485 integration quotes surprise people.

Because the cable is passive, the failure modes are mechanical: a bent pin, a worn connector after years of field use, or a cable left coiled in a hot cabinet. Keep a spare; it costs little and it is the fastest way to rule out the cable when a serial link stops working.

Commissioning in five steps

  1. Install the module in any slot of the chassis — 1756-IN587 states that slot 0 is the leftmost slot to the right of the power supply and that the module can go in any slot. Multiple 1756-DH485 modules may share one chassis, limited by the supply rating.
  2. Connect each channel to a 1761-NET-AIC converter with a 1756-CP3 cable: the right-angle connector end goes to the AIC+, the straight end to the module. The module cannot be wired straight to the DH-485 trunk.
  3. Configure the module from RSLinx, version 2.43 or later — 1756-IN587 names that version as the tool that sets the network parameters.
  4. Use Belden 9463 twinaxial cable, 20 AWG (0.519 mm2), with conductor category 2 routing, and tighten the connector to 0.5...0.6 Nm.
  5. Set the communication rate deliberately: the published rates are 19.2 Kbps (default) and 9600. A new module on an existing network has to match the network, not the default.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Connector orientation Right-angle end to the 1761-NET-AIC, straight end to the module (1756-IN587). Reversing it changes the clearance behind the panel and can strain the module port.
 Check 3 Serial port on the terminal The cable is RS-232. A modern laptop without a serial port needs a USB-to-serial adapter, and that adapter is a second failure point to test before blaming the controller.
 Check 4 Active mature, not obsolete Lifecycle is published as active, mature — the part is available, but the serial-programming route itself belongs to older practice. Design new networks on EtherNet/IP.
 Check 5 One cable per converter An AIC+ serves one channel. Two channels, two converters, two cables.

Specifications and wiring per Rockwell publication 1756-IN587 (ControlLogix DH-485 Communications Module installation instructions); product attributes per the Rockwell product record and 1756-IN050.

Replacing a serial and DH-485 connection

There is no substitute part in the ControlLogix catalogue — the cable is named as the connection in the DH-485 installation instructions, and the AIC+ procedure depends on it.

For programming, the modern route is the controller's Ethernet port and no cable at all. The CP3 remains the fallback for controllers without a reachable network port.

For new DH-485 integration, the network itself is the thing to question: 1756-CN2 and 1756-EN2T modules on ControlNet or EtherNet/IP remove the converter, the cable and the second network from the design.

Which ControlLogix EtherNet/IP module to specify

  • 1756-CP3 — the Logix family RS-232 programmer cable; used for controller programming and, per 1756-IN587, to connect each 1756-DH485 channel to a 1761-NET-AIC converter.
  • 1756-DH485 — DH-485 communications module, two 9-pin D-shell channels, 850 mA at 5.1 V DC backplane load, isolated at 50 V.
  • 1761-NET-AIC — the AIC+ converter that each DH-485 channel needs before it can reach the network; the module has no direct DH-485 terminal.
  • 1756-DHRIO — the DH+ and remote I/O scanner; a different network, not a substitute for DH-485.
  • 1756-CN2 / 1756-EN2T — current ControlNet and EtherNet/IP modules; the migration path for a network that no longer needs DH-485.

FAQ — 1756-CP3 Logix RS232 Programmer Cable | Rockwell

What is the 1756-CP3?

The Logix family RS-232 programmer cable, published by Rockwell as the Logix5000 RS232 Programmer Cable.

What is it used for?

Connecting a programming terminal to a Logix controller's serial port, and connecting each 1756-DH485 channel to a 1761-NET-AIC converter.

Does a 1756-DH485 need one?

Yes — one per channel. 1756-IN587 directs each channel to a 1761-NET-AIC converter through a 1756-CP3 cable.

Which end goes where?

Right-angle connector to the 1761-NET-AIC converter, straight connector to the module, as printed in 1756-IN587.

Is it still produced?

Lifecycle is active, mature: available, with a published 5 day lead time and one year warranty.

What is the temperature rating?

0...60 °C (32...140 °F) as published.

Where is it made, and what is the UPC?

Country of origin China, UPC 612598173785.

What documents cover it?

Installation instructions 1756-IN046, technical data 1756-TD002 and selection guide 1756-SG001.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-CP3. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)