The 1756-CFM (also written 1756CFM) is the ControlLogix configurable flowmeter module: two channels, four inputs (two flowmeter inputs per channel plus two gate inputs used in Totalizer mode), two current-sourcing outputs, and 100 kHz maximum flowmeter input frequency.
Published figures are 300 mA at 5.1 V DC and 16 mA (series A) or 25 mA (series B) at 24 V DC, 1.7 W or 2.13 W total backplane power, 6 W and 20.4 BTU/hr on series A against 3.12 W and 10.6 BTU/hr on series B. Isolation is 250 V continuous reinforced (I/O to backplane) and 250 V basic (group to group). Count range is 2,147,483,647 with 0.0005 Hz frequency resolution, input thresholds of 50 mV, 1.3 V and 4 V, and 5 kΩ ±30% flowmeter input impedance (1756-TD002N).
1756-HSC/A, 1756-HSC/B |
2 counters, 4 outputs, 300 mA at 5.1 V DC, 5.6 W, 1756-TBCH |
In stock |
1756-HSC/C, 1756-HSC/D |
2 counters, 4 outputs, 300 mA at 5.1 V DC, 3.5 W, 1756-TBS6H |
In stock |
1756-CFM/A |
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 6 W |
In stock |
1756-CFM/B |
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 3.12 W |
In stock |
1756-TBCH |
16-point removable terminal block, HSC series A/B |
In stock |
1756-TBS6H |
Spring-clamp terminal block, HSC series C/D |
In stock |
Application |
Configurable flowmeter |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-CFM |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-CFM |
Mounting |
Chassis |
Number Of Channels |
1756-CFM |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Communication Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The CFM exists where a flow signal is not simply an analog value: proving runs need a gate input to open and close the count window, and custody or blending duty needs the total to survive the scan. That is why the module has gate inputs and outputs of its own rather than a single analog channel.
Two channels suit a meter run with a prover, a blending skid with two flow streams, or a load rack where the same skid meters two products. The 100 kHz ceiling covers turbine and positive-displacement meters with margin; the practical limit is the pickup, not the module.
The output pair is what makes the module self-contained: a prover valve can be driven from the same slot that counts the pulses, so the proving sequence does not depend on the controller scan time.
A counter or flowmeter module has no indicator that explains a bad reading; its limits are the numbers that decide whether the pulse train can be captured at all. Every row below is quoted from the module specification 1756-TD002N.
| Indicator | State | Meaning and first action |
| Inputs | 4 (2 per channel) | Two flowmeter F inputs used in all modes, plus two gate inputs for prover/store count in Totalizer mode. |
| Outputs | 2, current sourcing | Used for valve or prover control without a separate output module. |
| Maximum flowmeter frequency | 100 kHz | Overrange occurs at 100 kHz; filtering is selectable between 100 kHz high-speed and a low-pass filter below 70 Hz. |
| Count range | 2,147,483,647 | With 0.0005 Hz frequency resolution. |
| Input thresholds | 50 mV, 1.3 V, 4 V (selectable) | ±30 V peak unterminated; 1.3 V DC and above reads logic 1, -0.7…1.3 V DC reads logic 0 in the magnetic-pickup range. |
| Gate inputs | 4.5…5.5 V DC at 5 V, 10…26.4 V DC at 12/24 V | Minimum on-state current 4 mA, nominal 15 mA. |
| Backplane current | 300 mA at 5.1 V DC; 16 mA (A) or 25 mA (B) at 24 V DC | Total backplane power 1.7 W (A) and 2.13 W (B). |
| Dissipation and isolation | 6 W (A) / 3.12 W (B); 250 V reinforced I/O to backplane | Thermal 20.4 BTU/hr against 10.6 BTU/hr; group-to-group isolation is 250 V basic. |
Inputs, frequency limits, current draw, dissipation and isolation per Rockwell publication 1756-TD002N-EN-E (1756 ControlLogix I/O Modules Specifications) and 1756-IN050.
Series A and B differ in 24 V current (16 mA against 25 mA), backplane power (1.7 W against 2.13 W) and dissipation (6 W against 3.12 W). A like-for-like replacement has to match the series, because the 24 V budget and the enclosure thermal calculation both change.
Where only a rate or total is needed and no gate logic is involved, a 1756-HSC or an analog input with a software totaliser covers the duty; where the meter is a Coriolis or vortex device with a 4…20 mA output, the CFM adds nothing over an analog input.
How many channels does the 1756-CFM have?
Two flowmeter channels, each with two flowmeter inputs and two gate inputs used in Totalizer mode, plus two current-sourcing outputs (1756-TD002N).
What is the maximum input frequency?
100 kHz on the flowmeter inputs, with overrange at that limit; a low-pass filter is selectable for frequencies below 70 Hz.
What is the count range?
2,147,483,647, with 0.0005 Hz frequency resolution.
What input thresholds can be selected?
50 mV, 1.3 V and 4 V, for magnetic pickup, TTL-compatible and 12/24 V preamplifier signals respectively.
How much backplane current does it draw?
300 mA at 5.1 V DC and 16 mA (series A) or 25 mA (series B) at 24 V DC; 1.7 W or 2.13 W total backplane power.
What is the dissipation?
6 W and 20.4 BTU/hr on series A, 3.12 W and 10.6 BTU/hr on series B.
What isolation is specified?
250 V continuous reinforced insulation from I/O to backplane, and 250 V basic between I/O groups.
Which terminal block and slot width?
One slot width; the module uses the standard 1756 removable terminal blocks and electronic, software-configurable keying.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (1756 ControlLogix I/O Modules Specifications) and the manufacturer's product page for 1756-CFM. Values re-checked 16 November 2026.