logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-CFM / 1756CFM

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-CFM / 1756CFM

China Allen Bradley PLC 1756-CFM / 1756CFM supplier
Allen Bradley PLC 1756-CFM / 1756CFM supplier Allen Bradley PLC 1756-CFM / 1756CFM supplier Allen Bradley PLC 1756-CFM / 1756CFM supplier Allen Bradley PLC 1756-CFM / 1756CFM supplier Allen Bradley PLC 1756-CFM / 1756CFM supplier Allen Bradley PLC 1756-CFM / 1756CFM supplier

Large Image :  Allen Bradley PLC 1756-CFM / 1756CFM

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CFM / 1756CFM

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $985.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 3 PCS
Detailed Product Description

1756-CFM technical data PDF download ControlLogix 1756-CFM / 1756CFM Configurable Flowmeter Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CFM (also written 1756CFM) is the ControlLogix configurable flowmeter module: two channels, four inputs (two flowmeter inputs per channel plus two gate inputs used in Totalizer mode), two current-sourcing outputs, and 100 kHz maximum flowmeter input frequency.

Published figures are 300 mA at 5.1 V DC and 16 mA (series A) or 25 mA (series B) at 24 V DC, 1.7 W or 2.13 W total backplane power, 6 W and 20.4 BTU/hr on series A against 3.12 W and 10.6 BTU/hr on series B. Isolation is 250 V continuous reinforced (I/O to backplane) and 250 V basic (group to group). Count range is 2,147,483,647 with 0.0005 Hz frequency resolution, input thresholds of 50 mV, 1.3 V and 4 V, and 5 kΩ ±30% flowmeter input impedance (1756-TD002N).

1756-HSC/A, 1756-HSC/B
2 counters, 4 outputs, 300 mA at 5.1 V DC, 5.6 W, 1756-TBCH
In stock
1756-HSC/C, 1756-HSC/D
2 counters, 4 outputs, 300 mA at 5.1 V DC, 3.5 W, 1756-TBS6H
In stock
1756-CFM/A
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 6 W
In stock
1756-CFM/B
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 3.12 W
In stock
1756-TBCH
16-point removable terminal block, HSC series A/B
In stock
1756-TBS6H
Spring-clamp terminal block, HSC series C/D
In stock

 Application
 Configurable flowmeter
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CFM
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-CFM
 Mounting
 Chassis
 Number Of Channels
 1756-CFM
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CFM flowmeter module product photograph 1756-CFM, second view product photograph 1756-CFM, third view product photograph

Where the module sits in a typical system

The CFM exists where a flow signal is not simply an analog value: proving runs need a gate input to open and close the count window, and custody or blending duty needs the total to survive the scan. That is why the module has gate inputs and outputs of its own rather than a single analog channel.

Two channels suit a meter run with a prover, a blending skid with two flow streams, or a load rack where the same skid meters two products. The 100 kHz ceiling covers turbine and positive-displacement meters with margin; the practical limit is the pickup, not the module.

The output pair is what makes the module self-contained: a prover valve can be driven from the same slot that counts the pulses, so the proving sequence does not depend on the controller scan time.

Commissioning in five steps

  1. Decide the mode before the wiring: counter, rate measurement and encoder each publish a different maximum frequency (1 MHz, 500 kHz and 250 kHz on the 1756-HSC), and the terminal block assignment changes with the mode.
  2. Match the input threshold to the device: the HSC accepts 4.5…5.5 V DC for 5 V devices and 10…26.4 V DC for 12/24 V devices, with a minimum on-state current of 4 mA and 15 mA nominal. A magnetic pickup that cannot reach 4 mA will not be read reliably.
  3. Select the right terminal block: 1756-TBCH on the HSC series A and B, 1756-TBS6H on series C and D. The two are not interchangeable, and the isolation rating differs between the series as well.
  4. Check the 5.1 V budget at 300 mA per module (both HSC and CFM) and add the dissipation to the enclosure load: 5.6 W on HSC series A/B against 3.5 W on series C/D, 6 W on CFM/A against 3.12 W on CFM/B.
  5. For flow, confirm the prover/gate logic: the CFM uses two gate inputs per channel in Totalizer mode, and a missing gate signal shows up as a total that stops counting rather than as a fault.

Limits: inputs, frequency, current and isolation

A counter or flowmeter module has no indicator that explains a bad reading; its limits are the numbers that decide whether the pulse train can be captured at all. Every row below is quoted from the module specification 1756-TD002N.

 Indicator  State  Meaning and first action
 Inputs  4 (2 per channel)  Two flowmeter F inputs used in all modes, plus two gate inputs for prover/store count in Totalizer mode.
 Outputs  2, current sourcing  Used for valve or prover control without a separate output module.
 Maximum flowmeter frequency  100 kHz  Overrange occurs at 100 kHz; filtering is selectable between 100 kHz high-speed and a low-pass filter below 70 Hz.
 Count range  2,147,483,647  With 0.0005 Hz frequency resolution.
 Input thresholds  50 mV, 1.3 V, 4 V (selectable)  ±30 V peak unterminated; 1.3 V DC and above reads logic 1, -0.7…1.3 V DC reads logic 0 in the magnetic-pickup range.
 Gate inputs  4.5…5.5 V DC at 5 V, 10…26.4 V DC at 12/24 V  Minimum on-state current 4 mA, nominal 15 mA.
 Backplane current  300 mA at 5.1 V DC; 16 mA (A) or 25 mA (B) at 24 V DC  Total backplane power 1.7 W (A) and 2.13 W (B).
 Dissipation and isolation  6 W (A) / 3.12 W (B); 250 V reinforced I/O to backplane  Thermal 20.4 BTU/hr against 10.6 BTU/hr; group-to-group isolation is 250 V basic.

Inputs, frequency limits, current draw, dissipation and isolation per Rockwell publication 1756-TD002N-EN-E (1756 ControlLogix I/O Modules Specifications) and 1756-IN050.

Replacing a module inside an installed panel

Series A and B differ in 24 V current (16 mA against 25 mA), backplane power (1.7 W against 2.13 W) and dissipation (6 W against 3.12 W). A like-for-like replacement has to match the series, because the 24 V budget and the enclosure thermal calculation both change.

Where only a rate or total is needed and no gate logic is involved, a 1756-HSC or an analog input with a software totaliser covers the duty; where the meter is a Coriolis or vortex device with a 4…20 mA output, the CFM adds nothing over an analog input.

Which counter or flowmeter module to specify

  • 1756-HSC — two counters, three inputs per counter (A, B, Z), four outputs, 1 MHz counting. For encoder, rate and totalizer duties on a fast shaft or a packaging line.
  • 1756-CFM — configurable flowmeter module, two channels, four inputs, two current outputs, 100 kHz flowmeter input. For proving and totalising flow, not for general counting.
  • 1756-LSC8XIB8I — low-speed counter with 10…30 V inputs and 1 A outputs, where the pulse rate is slow and interlocking is wanted in the same module.
  • 1756-IB16ISOE — sequence-of-events input, where the requirement is timestamped status rather than counting.
  • 1756-IF8 — analog input, for flow signals that are already 4…20 mA and do not need a totaliser.

FAQ — ControlLogix 1756-CFM / 1756CFM Configurable Flowmeter Module

How many channels does the 1756-CFM have?

Two flowmeter channels, each with two flowmeter inputs and two gate inputs used in Totalizer mode, plus two current-sourcing outputs (1756-TD002N).

What is the maximum input frequency?

100 kHz on the flowmeter inputs, with overrange at that limit; a low-pass filter is selectable for frequencies below 70 Hz.

What is the count range?

2,147,483,647, with 0.0005 Hz frequency resolution.

What input thresholds can be selected?

50 mV, 1.3 V and 4 V, for magnetic pickup, TTL-compatible and 12/24 V preamplifier signals respectively.

How much backplane current does it draw?

300 mA at 5.1 V DC and 16 mA (series A) or 25 mA (series B) at 24 V DC; 1.7 W or 2.13 W total backplane power.

What is the dissipation?

6 W and 20.4 BTU/hr on series A, 3.12 W and 10.6 BTU/hr on series B.

What isolation is specified?

250 V continuous reinforced insulation from I/O to backplane, and 250 V basic between I/O groups.

Which terminal block and slot width?

One slot width; the module uses the standard 1756 removable terminal blocks and electronic, software-configurable keying.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (1756 ControlLogix I/O Modules Specifications) and the manufacturer's product page for 1756-CFM. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)