Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-HSC / 1756HSC

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $587.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-HSC technical data PDF download ControlLogix 1756-HSC / 1756HSC High-Speed Counter Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-HSC (also written 1756HSC) is the ControlLogix high-speed counter: two counters, three inputs per counter (A, B and Z for gate or reset), four outputs in two groups, and 1 MHz counting on the A input.

Published figures are 300 mA at 5.1 V DC and 3 mA at 24 V DC from the backplane, 1.6 W total backplane power, 5.6 W maximum dissipation and 19.1 BTU/hr on series A and B, 3.5 W and 12 BTU/hr on series C and D. Isolation is 125 V continuous basic (input group to backplane) and 30 V basic (group to group) on series A/B, 250 V and 125 V on series C/D. Inputs accept 4.5…5.5 V DC at 5 V operation or 10…26.4 V DC at 12/24 V operation, with 4 mA minimum and 15 mA nominal on-state current, on the 1756-TBCH terminal block for series A/B and 1756-TBS6H for series C/D (1756-TD002N).

1756-HSC/A, 1756-HSC/B
2 counters, 4 outputs, 300 mA at 5.1 V DC, 5.6 W, 1756-TBCH
In stock
1756-HSC/C, 1756-HSC/D
2 counters, 4 outputs, 300 mA at 5.1 V DC, 3.5 W, 1756-TBS6H
In stock
1756-CFM/A
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 6 W
In stock
1756-CFM/B
Flowmeter module, 2 channels, 300 mA at 5.1 V DC, 3.12 W
In stock
1756-TBCH
16-point removable terminal block, HSC series A/B
In stock
1756-TBS6H
Spring-clamp terminal block, HSC series C/D
In stock

 Application
 High-speed counter
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-HSC
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-HSC
 Mounting
 Chassis
 Number Of Channels
 1756-HSC
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-HSC module product photograph 1756-HSC, second view product photograph 1756-HSC, third view product photograph

Where the module sits in a typical system

The HSC is bought for one of three jobs: totalising a fast pulse train, measuring rate for a speed loop, or reading a quadrature encoder for position. Each has its own frequency ceiling and its own use of the A, B and Z inputs, which is why the same module appears in very different applications.

On a packaging line it usually counts product or reads the line encoder; in a converting section it measures rate; on a test stand it captures a burst of pulses far faster than the I/O scan could sample. The common thread is that the count has to be accurate at pulse rates the standard digital input modules cannot follow.

The four outputs let the module act on its own count without waiting for the controller scan, which is the practical reason to use an HSC rather than a fast digital input and a software counter.

Commissioning in five steps

  1. Decide the mode before the wiring: counter, rate measurement and encoder each publish a different maximum frequency (1 MHz, 500 kHz and 250 kHz on the 1756-HSC), and the terminal block assignment changes with the mode.
  2. Match the input threshold to the device: the HSC accepts 4.5…5.5 V DC for 5 V devices and 10…26.4 V DC for 12/24 V devices, with a minimum on-state current of 4 mA and 15 mA nominal. A magnetic pickup that cannot reach 4 mA will not be read reliably.
  3. Select the right terminal block: 1756-TBCH on the HSC series A and B, 1756-TBS6H on series C and D. The two are not interchangeable, and the isolation rating differs between the series as well.
  4. Check the 5.1 V budget at 300 mA per module (both HSC and CFM) and add the dissipation to the enclosure load: 5.6 W on HSC series A/B against 3.5 W on series C/D, 6 W on CFM/A against 3.12 W on CFM/B.
  5. For flow, confirm the prover/gate logic: the CFM uses two gate inputs per channel in Totalizer mode, and a missing gate signal shows up as a total that stops counting rather than as a fault.

Limits: inputs, frequency, current and isolation

A counter or flowmeter module has no indicator that explains a bad reading; its limits are the numbers that decide whether the pulse train can be captured at all. Every row below is quoted from the module specification 1756-TD002N.

 Indicator  State  Meaning and first action
 Inputs per counter  3 (A, B, Z)  A and B for pulse or quadrature, Z for gate or reset depending on the mode.
 Outputs  4 (2 points per group)  Current-sourcing outputs, grouped in pairs; group-to-group isolation is published separately from group-to-backplane.
 Maximum input frequency  1 MHz counter mode, 500 kHz rate mode, 250 kHz encoder mode  The frequency ceiling depends on the mode selected; 70 Hz applies when the input filter is enabled.
 Count range  0…16,777,214  24-bit range per counter.
 Input threshold  5 V: 4.5…5.5 V DC; 12/24 V: 10…26.4 V DC  Minimum on-state current 4 mA, nominal 15 mA.
 Backplane current  300 mA at 5.1 V DC, 3 mA at 24 V DC  Total backplane power 1.6 W.
 Dissipation  5.6 W (A/B), 3.5 W (C/D)  19.1 BTU/hr against 12 BTU/hr; both add to the enclosure thermal load.
 Terminal block  1756-TBCH (A/B), 1756-TBS6H (C/D)  The series also changes the isolation rating, so the block and the rating are one decision.

Inputs, frequency limits, current draw, dissipation and isolation per Rockwell publication 1756-TD002N-EN-E (1756 ControlLogix I/O Modules Specifications) and 1756-IN050.

Replacing a module inside an installed panel

Series matters more than catalogue number here. A 1756-HSC/A or /B uses the 1756-TBCH terminal block and publishes 125 V group-to-backplane isolation; a /C or /D uses the 1756-TBS6H and publishes 250 V. Replacing one series with the other changes both the wiring hardware and the isolation rating of the circuit.

Where the pulse rate is slow enough for a standard input, the 1756-IB16ISOE or a DC input module with a software counter removes the cost of the HSC slot; where the count is flow rather than pulses, the 1756-CFM is the correct module and the HSC is the wrong one.

Which counter or flowmeter module to specify

  • 1756-HSC — two counters, three inputs per counter (A, B, Z), four outputs, 1 MHz counting. For encoder, rate and totalizer duties on a fast shaft or a packaging line.
  • 1756-CFM — configurable flowmeter module, two channels, four inputs, two current outputs, 100 kHz flowmeter input. For proving and totalising flow, not for general counting.
  • 1756-LSC8XIB8I — low-speed counter with 10…30 V inputs and 1 A outputs, where the pulse rate is slow and interlocking is wanted in the same module.
  • 1756-IB16ISOE — sequence-of-events input, where the requirement is timestamped status rather than counting.
  • 1756-IF8 — analog input, for flow signals that are already 4…20 mA and do not need a totaliser.

FAQ — ControlLogix 1756-HSC / 1756HSC High-Speed Counter Module

How many counters does the 1756-HSC have?

Two counters with three inputs each (A, B, Z for gate or reset) and four outputs in two groups (1756-TD002N).

What is the maximum input frequency?

1 MHz in counter mode on the A input, 500 kHz in rate measurement mode, 250 kHz in encoder mode with A/B inputs, and 70 Hz with the input filter enabled.

What is the count range?

0…16,777,214, a 24-bit range.

What input voltages are accepted?

4.5…5.5 V DC at 5 V operation and 10…26.4 V DC at 12/24 V operation, with 4 mA minimum and 15 mA nominal on-state current.

How much backplane current does it draw?

300 mA at 5.1 V DC and 3 mA at 24 V DC, 1.6 W total backplane power.

What is the dissipation and what terminal block is used?

5.6 W and 19.1 BTU/hr on series A/B with the 1756-TBCH; 3.5 W and 12 BTU/hr on series C/D with the 1756-TBS6H.

What isolation is published?

125 V continuous basic input group to backplane and 30 V group to group on series A/B; 250 V and 125 V respectively on series C/D.

Is it a substitute for a flowmeter module?

No. The HSC counts pulses; the 1756-CFM adds gate inputs and current outputs for proving and totalising flow.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (1756 ControlLogix I/O Modules Specifications) and the manufacturer's product page for 1756-HSC. Values re-checked 16 November 2026.