logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-HIST2G / 1756HIST2G

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-HIST2G / 1756HIST2G

China Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier
Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier Allen Bradley PLC 1756-HIST2G / 1756HIST2G supplier

Large Image :  Allen Bradley PLC 1756-HIST2G / 1756HIST2G

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-HIST2G / 1756HIST2G

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $5415.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-HIST2G technical data PDF download FactoryTalk Historian ME 1756-HIST2G / 1756HIST2G 2 GB

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-HIST2G (also written 1756HIST2G) is the FactoryTalk Historian Machine Edition with 2 GB of onboard storage: a Historian ME module that sits in a ControlLogix chassis and archives plant data without a separate server. Rockwell lists it as active, series C, UPC 612598903160, with an estimated lead time of 38 days and a one-year standard warranty.

It is the functional replacement for the discontinued 1756-HIST1G, which ended on 28 February 2017. The published firmware for the series C module runs from v7.100 to v7.103, and Rockwell points to three documents: the installation instructions 1756-IN106, ENET-IN002 for the network interface, and the technical data 1756-TD002. This page states the identity and lifecycle fields as Rockwell publishes them; the electrical ratings belong in the technical data and are not restated here as if they were measured.

1756-HIST2G
FactoryTalk Historian Machine Edition, 2 GB, series C, active
In stock
1756-HIST1G
FactoryTalk Historian Machine Edition, 1 GB, discontinued 2017-02-28
In stock
1756-EN2T
EtherNet/IP communication module, one copper port, 10/100 Mbps
In stock
1756-L71
ControlLogix 5570 controller, the usual tag source for the historian
In stock
1756-A7
7-slot chassis, the usual host for controller plus historian
In stock

 Application
 FactoryTalk Historian ME, 2 GB
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-HIST2G
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-HIST2G
 Mounting
 Chassis
 Number Of Channels
 1756-HIST2G
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-HIST2G historian module product photograph 1756-HIST2G, second view product photograph 1756-HIST2G, third view product photograph

Where the historian sits in a typical system

The Historian ME exists for the case where history has to be collected at the machine, not at a plant server. A packaging line, a skid or a remote pump station often has a controller and a network connection but no server room, and the 1756-HIST2G puts the archive in the chassis next to the controller.

The 2 GB model is chosen over the 1 GB model for one reason: retention. The number of points and the collection rate decide how long the archive lasts, and doubling the storage doubles that window at the same configuration. It does not make the module faster.

Where the data has to be joined with a plant-wide FactoryTalk Historian, the module is a collector rather than the final archive, and the network module in the same chassis — typically a 1756-EN2T — is what carries the replicated data out.

It is worth being clear about what this module is not: it is not a controller, it adds no I/O, and it does not replace the controller's own task and connection budget. It occupies a chassis slot and a network address.

Commissioning in five checks

  1. Give the module an IP address on the plant network before it is inserted, and confirm the address is not inside the controller's own subnet range. The historian is a network device with its own identity.
  2. Insert it in the chassis and let it boot fully: the front panel carries BAT, STS and OK indicators, and the OK indication is the one that matters before any configuration is attempted.
  3. Create the data points on the historian, not on the controller. The controller's job ends with the tag existing; what the historian archives, and at what rate, is configured on the historian side.
  4. Check the archive against the storage: a 2 GB module holds a defined volume of history, and the retention period is a function of point count and collection rate, not of the calendar.
  5. Record the firmware revision in the panel documentation. The series C Historian ME has published revisions from v7.100 to v7.103, and a revision mismatch between client tools and module is the usual cause of a failed first connection.

Identity, lifecycle and front-panel indicators

This table carries the fields Rockwell publishes for the catalogue number: product identity, series, lifecycle, UPC and indicators. Electrical ratings sit in the technical data 1756-TD002 and are not restated here as measured values.

 Indicator  State  Meaning and first action
 Series  C  The series is quoted on the order and matched to the firmware revision.
 Lifecycle  Active  Current catalogue item.
 UPC  612598903160  Rockwell product page identifier, used for order and inventory matching.
 Lead time  Estimated 38 days  Rockwell's published figure at the time of writing; it moves with allocation.
 Warranty  1 year standard  Rockwell standard warranty duration.
 Firmware  Series C v7.100 … v7.103 published  Match the module revision to the client tools before the first connection.
 Installation instructions  1756-IN106  The document that governs physical installation and wiring.
 Network reference  ENET-IN002  The network interface documentation Rockwell lists for this module.
 Technical data  1756-TD002  Where the electrical and environmental ratings are published.
 Certifications  CE, RCM, UKCA, Morocco (status as of 30 September 2026)  Certification status is dated; check the label on the delivered unit.
 Replaces  1756-HIST1G (discontinued 28 February 2017)  Functional replacement, not a drop-in of the same series.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a historian inside an installed chassis

The 1756-HIST1G is replaced functionally by the 1756-HIST2G, and Rockwell states the replacement relationship explicitly. The series changes from A to C, so the firmware revision and the client tools are part of the replacement, not an afterthought.

Treat the swap as a data migration: the points, the collection rates and the retention policy are configuration that has to be re-established on the new module, and the old archive is a file to be exported, not a state that carries over.

In an installed chassis, the physical fit is the easy part. The part that needs planning is the network address and the client-tool revision, because those are what the operators notice if they are wrong.

Which Historian ME module to specify

  • 1756-HIST2G — FactoryTalk Historian Machine Edition with 2 GB of onboard storage, series C, active and ordered today; UPC 612598903160.
  • 1756-HIST1G — the original 1 GB Historian ME, discontinued 28 February 2017; replaced functionally by the 1756-HIST2G.
  • 1756-EN2T — the network module that carries the historian data to the plant network when the archive has to live off-chassis.
  • 1756-L7x — the controllers whose tags the Historian ME collects from the backplane.
  • 1756-A7 / 1756-A13 — the chassis that host the historian alongside the controller.

FAQ — FactoryTalk Historian ME 1756-HIST2G / 1756HIST2G 2 GB

What is the 1756-HIST2G?

FactoryTalk Historian Machine Edition, 2 GB, a Historian ME module for a ControlLogix chassis. Rockwell lists it as active, series C.

What is its UPC?

612598903160.

What does the 2 GB refer to?

Onboard storage for the historian archive; it sets the retention window at a given point count and collection rate.

Which model did it replace?

The 1756-HIST1G, which Rockwell discontinued on 28 February 2017 and lists the 1756-HIST2G as the functional replacement for.

What series is the module?

Series C, with published firmware from v7.100 to v7.103.

Which documents apply?

Installation instructions 1756-IN106, network reference ENET-IN002 and technical data 1756-TD002.

Is it still available?

Yes, the lifecycle status is active, with an estimated lead time of 38 days at the time of writing.

What is the warranty?

One year, Rockwell's standard warranty duration for this product.


Data sources. Technical values on this page come from Rockwell publications product page for 1756-HIST2G (lifecycle status, series, UPC, country of origin, firmware, documents) and the manufacturer's product page for 1756-HIST2G. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)