The 1756-HIST2G (also written 1756HIST2G) is the FactoryTalk Historian Machine Edition with 2 GB of onboard storage: a Historian ME module that sits in a ControlLogix chassis and archives plant data without a separate server. Rockwell lists it as active, series C, UPC 612598903160, with an estimated lead time of 38 days and a one-year standard warranty.
It is the functional replacement for the discontinued 1756-HIST1G, which ended on 28 February 2017. The published firmware for the series C module runs from v7.100 to v7.103, and Rockwell points to three documents: the installation instructions 1756-IN106, ENET-IN002 for the network interface, and the technical data 1756-TD002. This page states the identity and lifecycle fields as Rockwell publishes them; the electrical ratings belong in the technical data and are not restated here as if they were measured.
1756-HIST2G |
FactoryTalk Historian Machine Edition, 2 GB, series C, active |
In stock |
1756-HIST1G |
FactoryTalk Historian Machine Edition, 1 GB, discontinued 2017-02-28 |
In stock |
1756-EN2T |
EtherNet/IP communication module, one copper port, 10/100 Mbps |
In stock |
1756-L71 |
ControlLogix 5570 controller, the usual tag source for the historian |
In stock |
1756-A7 |
7-slot chassis, the usual host for controller plus historian |
In stock |
Application |
FactoryTalk Historian ME, 2 GB |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-HIST2G |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-HIST2G |
Mounting |
Chassis |
Number Of Channels |
1756-HIST2G |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Communication Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The Historian ME exists for the case where history has to be collected at the machine, not at a plant server. A packaging line, a skid or a remote pump station often has a controller and a network connection but no server room, and the 1756-HIST2G puts the archive in the chassis next to the controller.
The 2 GB model is chosen over the 1 GB model for one reason: retention. The number of points and the collection rate decide how long the archive lasts, and doubling the storage doubles that window at the same configuration. It does not make the module faster.
Where the data has to be joined with a plant-wide FactoryTalk Historian, the module is a collector rather than the final archive, and the network module in the same chassis — typically a 1756-EN2T — is what carries the replicated data out.
It is worth being clear about what this module is not: it is not a controller, it adds no I/O, and it does not replace the controller's own task and connection budget. It occupies a chassis slot and a network address.
This table carries the fields Rockwell publishes for the catalogue number: product identity, series, lifecycle, UPC and indicators. Electrical ratings sit in the technical data 1756-TD002 and are not restated here as measured values.
| Indicator | State | Meaning and first action |
| Series | C | The series is quoted on the order and matched to the firmware revision. |
| Lifecycle | Active | Current catalogue item. |
| UPC | 612598903160 | Rockwell product page identifier, used for order and inventory matching. |
| Lead time | Estimated 38 days | Rockwell's published figure at the time of writing; it moves with allocation. |
| Warranty | 1 year standard | Rockwell standard warranty duration. |
| Firmware | Series C v7.100 … v7.103 published | Match the module revision to the client tools before the first connection. |
| Installation instructions | 1756-IN106 | The document that governs physical installation and wiring. |
| Network reference | ENET-IN002 | The network interface documentation Rockwell lists for this module. |
| Technical data | 1756-TD002 | Where the electrical and environmental ratings are published. |
| Certifications | CE, RCM, UKCA, Morocco (status as of 30 September 2026) | Certification status is dated; check the label on the delivered unit. |
| Replaces | 1756-HIST1G (discontinued 28 February 2017) | Functional replacement, not a drop-in of the same series. |
Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.
The 1756-HIST1G is replaced functionally by the 1756-HIST2G, and Rockwell states the replacement relationship explicitly. The series changes from A to C, so the firmware revision and the client tools are part of the replacement, not an afterthought.
Treat the swap as a data migration: the points, the collection rates and the retention policy are configuration that has to be re-established on the new module, and the old archive is a file to be exported, not a state that carries over.
In an installed chassis, the physical fit is the easy part. The part that needs planning is the network address and the client-tool revision, because those are what the operators notice if they are wrong.
What is the 1756-HIST2G?
FactoryTalk Historian Machine Edition, 2 GB, a Historian ME module for a ControlLogix chassis. Rockwell lists it as active, series C.
What is its UPC?
612598903160.
What does the 2 GB refer to?
Onboard storage for the historian archive; it sets the retention window at a given point count and collection rate.
Which model did it replace?
The 1756-HIST1G, which Rockwell discontinued on 28 February 2017 and lists the 1756-HIST2G as the functional replacement for.
What series is the module?
Series C, with published firmware from v7.100 to v7.103.
Which documents apply?
Installation instructions 1756-IN106, network reference ENET-IN002 and technical data 1756-TD002.
Is it still available?
Yes, the lifecycle status is active, with an estimated lead time of 38 days at the time of writing.
What is the warranty?
One year, Rockwell's standard warranty duration for this product.
Data sources. Technical values on this page come from Rockwell publications product page for 1756-HIST2G (lifecycle status, series, UPC, country of origin, firmware, documents) and the manufacturer's product page for 1756-HIST2G. Values re-checked 16 November 2026.