Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier Allen Bradley PLC 1756-EN2TR / 1756EN2TR supplier

Large Image :  Allen Bradley PLC 1756-EN2TR / 1756EN2TR

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-EN2TR / 1756EN2TR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1639.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description


1756-EN2TR technical data PDF download ControlLogix 1756-EN2TR / 1756EN2TR EtherNet/IP Module (2-Port DLR)

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-EN2TR (also written 1756EN2TR) is the dual-port EtherNet/IP communication module for the ControlLogix 1756 platform: two copper RJ45 ports rated Category 5E at 10/100 Mbps, chassis mounted, one slot wide. The second port is what separates it from the 1756-EN2T — both ports can carry a device-level ring (DLR) or a linear daisy chain, so the module itself is the point where the ring recovers.

Connection capacity is identical to the 1756-EN2T, so the EN2T/EN2TR choice is a topology decision, not a throughput decision: 128 TCP/IP connections, 256 CIP connections and 128 + 128 CIP unconnected messages (1756-TD003 Table 1). The second port costs 0.2 A — 1.2 A at 5.1 V DC, 6.12 W, 20.9 BTU/hr (Table 4) against 1 A on the single-port module — so the slot's 5.1 V budget is reopened on any swap. Firmware 2.x needs Studio 5000 / RSLogix 5000 17.01.02 or later and RSLinx 2.55 or later; from firmware 5.x the packet rate rises to 25,000 packets/s and up to eight integrated-motion axes are supported (Table 3).

1756-EN2FCLX HI CAP EIP MOD - FBRIN STOCK
1756-EN2TControlLogix Hi Capacity ENET/IPIN STOCK
1756-EN2TR2-PORT CLX HI-CAP ENET/IP MODULE - TPIN STOCK
1756-EN2TRXTCLX ENET/IP Module - 2TP -X EnvtIN STOCK
1756-EN2TSCEtherNet/IP Hi Prof Sngl Port VPN BridgeIN STOCK
1756-EN2TXTCLX ENET/IP MODULE - TP, X-ENVTIN STOCK
1756-EN3TRControlLogix Ethernet Motion ModuleIN STOCK
1756-ENBTControlLogix Communication ModuleIN STOCK
1756-EWEBControlLogix Web Server ModuleIN STOCK
1756-EXTControlLogix Backplane ExtenderIN STOCK
1756-HIST1GHistorian ME 1 Gig in ControlLogix RackIN STOCK
1756-HIST2GHistorian ME 2 Gig in ControlLogix RackIN STOCK
1756-HSCControlLogix High-Speed Counter ModuleIN STOCK
1756-HYD02ControlLogix Analog Combination ModuleIN STOCK

 Application
 EtherNet/IP
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-EN2TR
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 Copper RJ45 (10/100 Mbps, Category 5E)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-EN2TR sealed carton product photograph 1756-EN2TR cartons product photograph 1756-EN2TR carton labels product photograph

Where the module sits in a typical system

The module sits in one of two places. In a ring it is the controller-side node of a DLR loop that also holds the drives, remote I/O adapters and managed switches — port 1 goes to the upstream neighbour, port 2 to the downstream one, and the ring heals inside the module when a single cable or device is lost. In a star it is simply the uplink for the chassis, one port to the plant switch and the second port left free for a local service laptop or a passive tap.

Because it bridges the 1756 backplane, everything in the chassis — ControlNet, DeviceNet, DH+/RIO, serial, analogue and motion modules — becomes reachable over the same Ethernet drop, and the module routes messages between networks instead of a second bridge. The 128 CIP connections are shared between explicit and implicit use, so connection counting is per target device, not per port.

Commissioning in five steps

  1. Set the IP address before the module is inserted — BOOTP/DHCP server, or a static address written in Studio 5000 and sent on download. Duplicate-IP detection is active at all revisions (Table 2).
  2. Insert the module in any 1756 chassis slot: 1756-A4, A7, A10, A13 or A17; standard supplies 1756-PA72/PA75/PB72/PB75/PC75/PH75, redundant supplies 1756-PA75R/PB75R/PSCA2.
  3. Wire the RJ45 ports with shielded or unshielded twisted pair to Category 5E (Table 4) and stay inside the 100 m channel limit. The same category applies to both ports when they are used as a ring.
  4. Add the module to the I/O configuration in Studio 5000. The generic Ethernet module entry is enough for messaging; an EDS or Add-on Profile is needed only when the module is used as a ring supervisor or carries integrated motion.
  5. Power up and read the four indicators: OK, NET, LINK 1 and LINK 2. A dark NET with a dark LINK pair is an addressing or cabling fault, not a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 OK Flashing green Power-up self-test or firmware update in progress; wait for the solid state.
 OK Off No chassis power at the slot, or the module has failed its self-test; check the supply and reseat.
 NET Green solid CIP connections established to at least one device.
 NET Flashing green IP address present, no CIP connection — check the connection entry and the message path in Studio 5000.
 NET Off No IP address; the module is not on the network yet.
 LINK 1 / LINK 2 Green solid Port linked and running at 10 or 100 Mbps.
 LINK 1 / LINK 2 Off No link on that port: cable, connector or partner port.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 1756-ENBT was discontinued by Rockwell on 1 November 2021 and the published replacement is the 1756-EN2T. The EN2TR is the right substitute when the failed node was part of a ring, because the ENBT had a single port and the ring had to be closed elsewhere.

The swap is mechanical and electrical, not programmatic: same slot, same chassis, and the 128 CIP connections of the EN2T replacement exceed the 64 of the ENBT, so an existing program keeps working. Recalculate the 5.1 V budget first — the ENBT draws 700 mA, the EN2TR 1.2 A, 500 mA more per substituted slot. Then confirm the ring: if the old node was closed by an external switch, the second port takes over and the switch can go.

Which ControlLogix EtherNet/IP module to specify

  • 1756-EN2T — single port, 128 TCP / 256 CIP, 1 A at 5.1 V. Star topology, cheapest slot budget.
  • 1756-EN2TR — this catalogue number. Two ports, EN2T connection counts, 1.2 A. DLR ring or linear chain, ring supervisor support.
  • 1756-EN2TRXT — the same module in the XT range, -25…+70 °C, conformal coated.
  • 1756-EN2TP — two ports for parallel redundancy (PRP), no ring; for redundancy between two independent networks.
  • 1756-EN3TR — two ports with integrated motion up to 128 axes; when the ring also carries servos.
  • 1756-EN4TR — 512 TCP / 1000 I/O connections, 1 Gbps capable, CIP Security, redundant adapters; large cells and segmented networks.
  • 1756-EN2F — fibre port, 100 Mbps fixed, for links beyond copper distance or through high-EMI areas.

FAQ — ControlLogix 1756-EN2TR / 1756EN2TR EtherNet/IP Module (2-Port DLR)

How does the 1756-EN2TR differ from the 1756-EN2T?

Only in the ports and topology. Both carry 128 TCP/IP connections, 256 CIP connections and 128 + 128 CIP unconnected messages (1756-TD003 Table 1). The EN2TR adds a second RJ45 port rated Category 5E and can act as a device-level ring node or ring supervisor; the EN2T has one Category 5 port and needs an external switch to close a ring.

What is required to run a device-level ring on this module?

Both ports are in the ring, one module in the loop is configured as ring supervisor in Studio 5000, and every node supports DLR. Cable on both ports must meet Category 5E as listed in Table 4, each segment stays inside the 100 m channel limit, and a single break is healed without dropping the connections that pass through it.

Which cable category and connector does the module need?

Two RJ45 ports, Category 5E shielded or unshielded twisted pair, 802.3 compliant (Table 4). Category 5E is the published rating for the dual-port module — Category 5 is listed for the single-port 1756-EN2T — so a ring built on older Cat 5 patch leads is outside the specification even when the link negotiates at 100 Mbps.

Can the module be removed or inserted with power on?

Yes. The 1756 platform supports removal and insertion under power, and the module is one slot with no wiring other than the RJ45 plugs.

What are the environmental limits and certifications?

Operating 0…60 °C in a Series C chassis, 0…50 °C in a Series B chassis; storage -40…85 °C; 5…95% RH non-condensing; 2 g vibration at 10…500 Hz; 30 g operating shock; CISPR 11 Class A emissions; ESD 6 kV contact and 8 kV air; EFT ±3 kV at 5 kHz and surge ±2 kV line-earth on the Ethernet ports; temperature code T4; open-style enclosure (Tables 4 and 5). Certifications: c-UL-us UL E65584 and Class I Division 2 UL E194810, CE to 2014/30/EU, RCM, ATEX 2014/34/EU II 3 G Ex ec IIC T4 Gc under UL 22 ATEX 2818X, UKEX UL22UKEX2604X, UKCA, FM Class I Division 2, IECEx UL 22.0063X, KC, ODVA conformance, CCC 2020122309111998 (Table 6).


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-EN2TR. Values re-checked 15 November 2026.

How much current does the 1756-EN2TR draw from the backplane?

1.2 A at 5.1 V DC and 3 mA at 24 V DC, dissipating 6.12 W and 20.9 BTU/hr, with 30 V continuous basic isolation type tested at 860 V AC for 60 s (1756-TD003 Table 4).

Which firmware and software versions does the 1756-EN2TR need?

Firmware 2.x needs RSLogix 5000 17.01.02 with RSLinx 2.55 and runs at 10,000 packets/s. Firmware 5.x needs 18.02.00 with RSLinx 2.56, runs at 25,000 packets/s and supports up to eight integrated-motion axes (Table 3).

Which chassis and power supplies are approved for it?

Any slot of 1756-A4, A7, A10, A13 or A17 with the PA72, PA75, PB72, PB75, PC75 or PH75 supply, or the redundant PA75R, PB75R and PSCA2 pairing (Table 4).

Which certifications does the 1756-EN2TR carry?

c-UL-us UL E65584 and Class I Division 2 UL E194810, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc under UL 22 ATEX 2818X, UKEX UL22UKEX2604X, UKCA, FM Class I Division 2, IECEx UL 22.0063X, KC, ODVA conformance, Morocco and CCC 2020122309111998. CSA is not listed against this module in Table 6.