The 1756-IF16H (also written 1756IF16H) is the 16-channel HART analog input: sixteen differential current inputs, each carrying a 4...20 mA measurement and a HART digital channel, with a modem per channel on the B series and a single multiplexed modem on the A series (1756-TD002).
The published series split is A series 200 mA at 5.1 V DC and 125 mA at 24 V DC, 4.02 W, 50 V basic isolation against B series 230 mA at 5.1 V DC and 100 mA at 24 V DC, 3.58 W, 250 V reinforced isolation. Sixteen channels for 200 mA is the lowest backplane cost per HART channel in the range.
Input impedance is 249 Ω, module error 0.3 %, and resolution runs from 16 to 21 bits with the range configuration. The channels are current inputs only.
The density has a wiring consequence: thirty-two conductors and sixteen HART instruments on one terminal block. HART communication depends on the loop impedance and the cable, so the installation instructions matter as much as the specification when sixteen loops land in one slot. Technical data 1756-TD002, user manual 1756-UM009, installation instructions 1756-IN063.
1756-IF4FXOF2F |
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation |
In stock |
1756-IF6CIS |
6 isolated current inputs with sourcing 24 V DC loop supply |
In stock |
1756-IF6I |
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation |
In stock |
1756-IF8 |
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane |
In stock |
1756-IF8H |
8 differential HART current inputs, A and B series |
In stock |
1756-IF16 |
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth |
In stock |
1756-IF16H |
16 differential HART current inputs, A and B series |
In stock |
1756-IRT8I |
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required |
In stock |
1756-IR6I |
6 isolated RTD inputs, 20-pin block, discontinued 2017 |
In stock |
1756-IT6I |
6 thermocouple inputs, two mV ranges, one CJC sensor |
In stock |
1756-IT6I2 |
6 isolated thermocouple inputs, 16-bit, two CJC sensors |
In stock |
Application |
Analog input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IF16H |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Analog Input Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IF16H is the module for a large instrumented area where HART data is wanted at scale: a tank farm with sixteen level and pressure transmitters, a boiler house, or a process unit where device diagnostics are part of the maintenance strategy.
Where the panel is a marshalling cabinet with a central 24 V supply and every instrument on the same reference, the sixteen-channel density pays for itself in slots and backplane current.
For fewer than eight instruments, the 1756-IF8H is the cheaper and simpler module; for measurement only, the 1756-IF16 does the same 16 channels without the HART hardware.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | A series: 50 V basic | The A series is not a field barrier. Panels that must demonstrate 250 V reinforced between field and control need the B series. |
| Check 3 | One modem per channel on B | On the A series HART is multiplexed; sixteen instruments polled in sequence takes sixteen times as long as one. On the B series they are independent. |
| Check 4 | 249 Ω loop burden | Sixteen loops each drop about 5 V at 20 mA across 249 Ω. The loop supply has to be sized for that on every channel. |
| Check 5 | Current only | No voltage range on this module; 0...10 V signals need a signal conditioner or a different input module. |
Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.
The 8-channel HART module is 1756-IF8H, published in the same A and B series split.
Without HART, 1756-IF16 measures 16 single-ended channels at 200 mA backplane, 35 mA at 24 V DC and 1.86 W.
For isolated HART channels, the B series IF16H is the only 16-channel option with 250 V reinforced isolation in this family.
What is the 1756-IF16H?
A 16-channel differential current input module with HART communication, published in A and B series.
What is the backplane current?
A series 200 mA at 5.1 V DC and 125 mA at 24 V DC (4.02 W); B series 230 mA at 5.1 V DC and 100 mA at 24 V DC (3.58 W).
What is the input impedance?
249 Ω, giving about 5 V across the input at 20 mA.
What accuracy is published?
0.3 % module error over the temperature range, with 16 to 21 bit resolution depending on the configured range.
How many HART modems?
One multiplexed modem on the A series; one per channel on the B series.
What isolation do the series provide?
50 V basic on the A series, 250 V reinforced on the B series.
Does it accept voltage signals?
No — the channels are current inputs.
What temperature code does it carry?
T4 for the module, per 1756-TD002.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IF16H. Values re-checked 15 November 2026.