logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IB16IF / 1756IB16IF

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IB16IF / 1756IB16IF

China Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier
Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier Allen Bradley PLC 1756-IB16IF / 1756IB16IF supplier

Large Image :  Allen Bradley PLC 1756-IB16IF / 1756IB16IF

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IB16IF / 1756IB16IF

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $335.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-IB16IF technical data PDF download 1756-IB16IF ControlLogix Fast Peer Control DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IB16IF (also written 1756IB16IF) is the fast peer-control input module: 16 inputs, operating range 10...30 V DC, maximum input current 5 mA — half the burden of a standard 1756-IB16 — with a backplane load of 275 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).

The two numbers tell the story. A standard input module draws 10 mA per point from the field circuit and 100 mA from the backplane; this one draws 5 mA from the field and 275 mA from the backplane. The field burden is halved and the backplane cost nearly tripled, because the fast path and the isolation are paid for out of the backplane.

Isolation is 250 V continuous reinforced from inputs to backplane and 250 V basic from input to input — put together, that is a stronger arrangement than the standard IB16, which has no isolation inside a group but also no input-to-input isolation at all. Here every input is separated from every other input.

The 5 mA input current matters most on two-wire sensors running near the edge of their leakage budget: a device that leaks 1.5 mA off-state can look 'on' to a 5 mA module when it would look off to a 10 mA one. Check the sensor's off-state leakage against the module's threshold before assuming the fast module is a drop-in.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IB16IF
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IB16IF module product photograph 1756-IB16IF terminal side product photograph 1756-IB16IF module view product photograph

Where the module sits in a typical system

The module exists for fast, deterministic exchange between modules — peer control — where a signal has to reach an output module without waiting for a controller scan. Typical use is a high-speed interlock inside one chassis.

Because it isolates input to input, it also suits mixed-source panels where several machines feed one rack, although the 10...30 V DC window and the 275 mA backplane draw have to be checked first.

Its 5 mA burden makes it attractive for two-wire proximity sensors on long cables, provided the sensor's off-state leakage is well below the module's on threshold.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 275 mA backplane 2.75 times the standard module's 100 mA. In a chassis with several fast modules the 5.1 V budget becomes the constraint.
 Check 3 Input-to-input isolation 250 V basic between inputs, plus reinforced to the backplane — the module for channels that must not share a common.
 Check 4 10...30 V DC Not the 31.2 V window of the IB16. A 31 V field supply is outside this module's rating.
 Check 5 Peer control needs a producer Fast peer control exchanges data between modules without going through the controller. The behaviour is configured in the project, not in the wiring.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The standard module is 1756-IB16: 10...31.2 V DC, 10 mA, 100 mA backplane, no input-to-input isolation.

The sequence-of-events module is 1756-IB16ISOE: 10...55 V DC, 5.1 mA, 320 mA backplane, for time-stamped capture.

The isolated standard module is 1756-IB16I: 10...30 V DC, 10 mA, 135 mA backplane.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IB16IF ControlLogix Fast Peer Control DC Input | Rockwell

What is the 1756-IB16IF?

A 16-point fast peer-control DC input module, 10...30 V DC, 5 mA maximum input current.

What is the backplane current?

275 mA at 5.1 V DC and 3 mA at 24 V DC, per 1756-IN062.

Why is the input current only 5 mA?

The module is built for low field burden and fast response; the cost appears on the backplane instead of the field circuit.

What isolation does it provide?

250 V continuous reinforced inputs-to-backplane and 250 V basic input-to-input.

Can it replace a 1756-IB16 one for one?

No. The input range is 10...30 V DC instead of 10...31.2 V DC and the backplane draw is 275 mA instead of 100 mA.

What is 'peer control'?

Direct data exchange between modules in the same chassis without routing through the controller scan, configured in the Logix Designer project.

Does a low input current affect sensor compatibility?

Yes — a lower on-threshold means a sensor with significant off-state leakage may read as on. Check the device data.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IB16IF. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)