logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IA8D / 1756IA8D

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IA8D / 1756IA8D

China Allen Bradley PLC 1756-IA8D / 1756IA8D supplier
Allen Bradley PLC 1756-IA8D / 1756IA8D supplier Allen Bradley PLC 1756-IA8D / 1756IA8D supplier Allen Bradley PLC 1756-IA8D / 1756IA8D supplier Allen Bradley PLC 1756-IA8D / 1756IA8D supplier Allen Bradley PLC 1756-IA8D / 1756IA8D supplier

Large Image :  Allen Bradley PLC 1756-IA8D / 1756IA8D

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IA8D / 1756IA8D

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $328.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-IA8D technical data PDF download 1756-IA8D ControlLogix 8 Point 120V AC Input Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IA8D (also written 1756IA8D) is the 8-point AC input module: 120 V AC at 50/60 Hz, 16 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC, isolation 125 V continuous basic, inputs to backplane, with no isolation between individual inputs (1756-IN064).

The input current is the number that matters on this module. At 16 mA it draws more per point than any other 120 V AC input in the family — the IA16 and IA16I publish 13 mA and 15 mA — and that current is what makes a 120 V input immune to leakage from long field runs, to snubbers across a contactor coil, and to the off-state leakage of solid-state sensors nearby on the same panel.

The isolation arrangement is the limitation. All eight inputs share a common with no isolation between them, and the barrier to the backplane is 125 V basic rather than the 250 V published on the IA16 and IA32. Eight points from one 120 V feed is the intended wiring; eight points from eight different circuits is not.

The module sits in a single 1756 chassis slot and is configured in the Studio 5000 project like the rest of the family, with per-point filtering selected in the module properties rather than by a hardware switch. The 3 mA draw at 24 V DC is the highest of the AC input modules and is worth counting in a chassis with many I/O cards.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IA8D
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 8
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IA8D module product photograph 1756-IA8D label product photograph 1756-IA8D terminal side product photograph

Where the module sits in a typical system

The IA8D suits a small, self-contained 120 V AC pilot circuit — a handful of float switches, pressure switches or pushbuttons on one machine section, all fed from the same control transformer.

It is also the module to reach for when the field wiring is long and noisy. The 16 mA input current holds off leakage that would false-trigger a lighter module, and the cost is eight points per slot and a shared common.

Where more than eight 120 V signals are needed from one feed, the IA16 gives sixteen points at the same 100 mA backplane current, which is the more economical arrangement once the panel grows past eight signals.

Commissioning in five steps

  1. Check the module's published input current against the field device's leakage. A 120 V AC input at 13 mA will hold off a two-wire sensor that leaks a few milliamps; a low-current module will not. Input current is an immunity figure, not a burden.
  2. Decide the common arrangement before wiring, because the isolation table is per module and not per family. The IA16 has two groups of eight with 125 V between them, the IA8D has no isolation between its inputs at all, and the IA16I isolates every point — but only at 125 V.
  3. Confirm the nominal voltage against the published window, not against the panel label. The IA32 accepts 74...132 V AC, so it works on a 110 V nominal supply with deep brownout; a 240 V circuit needs the IM16I.
  4. Respect 60 °C as the surrounding-air limit and mount the module in a slot where the chassis airflow is unobstructed; every rating in 1756-IN064 is quoted at that ambient.
  5. Terminate on the 1756-TBNH or 1756-TBSH removable terminal block with 0.33...2.1 mm² (22...14 AWG) wire rated 90 °C or better, and 1.2 mm maximum insulation.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 125 V barrier, not 250 V Inputs-to-backplane is 125 V basic on the IA8D; the IA16 and IA32 publish 250 V. At 120 V nominal that is adequate, and it is not a 240 V module.
 Check 3 16 mA per point The highest input current in the 120 V family, which buys leakage immunity but loads the field circuit more heavily than the 13 mA modules.
 Check 4 8 points per slot Half the density of the IA16 at the same backplane current — the trade is wiring simplicity against slot count.
 Check 5 Temperature code T4A 120 °C maximum surface temperature under the North American classification published in 1756-IN064.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC input module of an earlier generation

For 16 points at 120 V AC with two isolated groups of eight, use 1756-IA16.

For 16 individually isolated 120 V AC inputs, use 1756-IA16I.

For 240 V AC signals, 1756-IM16I is the published option.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IA16 — 16 inputs at 120 V AC, 13 mA per point, two groups of eight with 125 V group-to-group isolation.
  • 1756-IA16I — 16 inputs individually isolated from each other, 120 V AC at 15 mA.
  • 1756-IA32 — 32 inputs in one slot, 74...132 V AC at 15 mA, the widest input window in the family.
  • 1756-IA8D — 8 inputs at 120 V AC with the highest input current, 16 mA per point.
  • 1756-IM16I — 16 isolated inputs at 240 V AC, the only 240 V AC input module published.
  • 1756-IN16 — 16 inputs at 10...30 V AC, 25 mA maximum per point.

FAQ — 1756-IA8D ControlLogix 8 Point 120V AC Input Module | Rockwell

What is the 1756-IA8D?

An 8-point 120 V AC input module, 16 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC.

What input voltage does it accept?

120 V AC at 50/60 Hz, as published in 1756-IN064.

How much current does each input draw?

16 mA at 120 V AC — the highest of the 120 V AC input modules in the family.

Does it isolate the inputs from each other?

No. All eight inputs share a common, with 125 V continuous basic isolation to the backplane only.

Can I use it on 240 V AC?

No. The isolation to the backplane is 125 V on this module, and the published input voltage is 120 V AC. Use 1756-IM16I for 240 V.

How much backplane current does it take?

100 mA at 5.1 V DC and 3 mA at 24 V DC.

What wire size fits the terminal block?

0.33...2.1 mm² (22...14 AWG) copper rated 90 °C or better, with 1.2 mm maximum insulation.

What is its temperature code?

T4A under the North American classification in 1756-IN064, with 60 °C maximum surrounding air.

Which document covers it?

1756-IN064, the installation instructions for the ControlLogix AC digital I/O modules.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IA8D. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)