logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-LSP / 1756LSP

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-LSP / 1756LSP

China Allen Bradley PLC 1756-LSP / 1756LSP supplier
Allen Bradley PLC 1756-LSP / 1756LSP supplier Allen Bradley PLC 1756-LSP / 1756LSP supplier Allen Bradley PLC 1756-LSP / 1756LSP supplier Allen Bradley PLC 1756-LSP / 1756LSP supplier Allen Bradley PLC 1756-LSP / 1756LSP supplier

Large Image :  Allen Bradley PLC 1756-LSP / 1756LSP

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-LSP / 1756LSP

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1395.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-LSP technical data PDF download GuardLogix Safety Partner 1756-LSP / 1756LSP (Discontinued)

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-LSP (also written 1756LSP) is the GuardLogix Safety Partner: the companion module that turns a GuardLogix 5560 safety controller into a controller pair in the chassis. Rockwell discontinued it on 1 June 2017 and lists the 1756-L7SP as the functional replacement.

The published product data is short and specific: UPC 612598321735, no embedded network port, the 1756-BA2 as the replacement battery, and a one-year standard warranty. There is no program in the safety partner — the safety task lives with the controller it is paired to — which is why the replacement is a safety-system change rather than a module swap.

1756-LSP
GuardLogix Safety Partner, discontinued 1 June 2017, UPC 612598321735
In stock
1756-L7SP
Current safety partner, functional replacement for 1756-LSP
In stock
1756-L61S
GuardLogix 5560 safety controller, 5561 class
In stock
1756-L62S
GuardLogix 5560 safety controller
In stock
1756-L63S
GuardLogix 5560 safety controller
In stock

 Application
 GuardLogix Safety Partner
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-LSP
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-LSP
 Mounting
 Chassis
 Number Of Channels
 1756-LSP
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-LSP safety partner product photograph 1756-LSP, second view product photograph 1756-LSP, third view product photograph

Where the safety partner sits in a typical system

In a GuardLogix 5560 system the safety architecture is a pair, not a single module: the controller and the safety partner are two cards in the chassis that together carry the safety task. The partner is what makes the pair, and without it the controller is not a GuardLogix safety controller.

That is why the 1756-LSP appears in panels that were built with 1756-L61S, L62S or L63S controllers. When a partner fails, the controller does not become a standard controller: the pair is incomplete, and the safety function is not available until the pair is whole again.

It is also why the part is searched for long after it stopped shipping. The installed base is real, the controllers are still in service, and the partner is the piece that fails quietly — a battery, a backplane contact — leaving a controller that looks healthy and a safety function that is not.

Commissioning the pair in five checks

  1. Fit the safety partner in the slot next to its partner controller. The pair is a controller pair for the chassis, and the slot order is part of the configuration the project expects.
  2. Record the battery: Rockwell lists the 1756-BA2 as the replacement battery for this module, and a safety partner with a flat battery behaves like a controller with a flat battery on the next power cycle.
  3. Check the firmware of the pair, not of the module. A safety partner carries no program of its own; its revision has to match the controller it is paired with.
  4. Treat any replacement as a safety-system change: the safety signature, the validated configuration and the documented proof test belong to the pair, and a swapped partner is a new configuration until it is re-validated.
  5. Keep the network path out of the decision. Rockwell lists the 1756-LSP with no embedded network port, so the network identity belongs to the controller or to the communication module in the same chassis, not to the partner.

Identity, lifecycle and what the partner does not do

A safety partner is judged by the pair it belongs to, not by a display of its own. The rows below are the fields Rockwell publishes for this catalogue number.

 Indicator  State  Meaning and first action
 Lifecycle  Discontinued 1 June 2017  Rockwell advises removing references to it from new designs.
 Replacement  1756-L7SP (functional replacement)  A series change, so firmware and validation are part of the migration.
 UPC  612598321735  Rockwell product page identifier.
 Embedded network port  None  The network identity belongs to the controller or the communication module in the chassis.
 Replacement battery  1756-BA2  The battery Rockwell lists for this module.
 Program storage  None of its own  The safety task belongs to the paired controller; the partner carries the pair's safety state.
 Warranty  1 year standard  Rockwell standard warranty duration.
 Slot  Next to its partner controller  The pair is configured as a pair; slot order is part of the project definition.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a safety partner inside an installed chassis

The 1756-L7SP is the functional replacement Rockwell names. Because the safety partner belongs to the safety signature of the pair, replacing it means re-validating the configuration and re-recording the signature, not just seating a card.

Carry the battery across in the plan: 1756-BA2 is the listed battery, and a replacement partner with an aged battery is a second failure waiting for the next power cycle.

Where the whole 5560 pair is being replaced by a 5570 or 5580 GuardLogix system, the safety partner question disappears into the controller migration, and the validation work moves with it.

Do not substitute a standard ControlLogix module for a partner. The partner is part of the safety architecture; a standard module in that slot removes the pair and with it the safety function.

Which safety partner to specify

  • 1756-LSP — the GuardLogix Safety Partner, discontinued 1 June 2017 and replaced functionally by the 1756-L7SP.
  • 1756-L7SP — the current safety partner for the 5570 GuardLogix family; the replacement Rockwell names for this part.
  • 1756-L61S / L62S / L63S — the GuardLogix 5560 safety controllers the safety partner is paired with in a 5560 system.
  • 1756-BA2 — the replacement battery Rockwell lists for the 1756-LSP.
  • 1756-A7 / 1756-A13 — the chassis that host a 5560 controller pair.

FAQ — GuardLogix Safety Partner 1756-LSP / 1756LSP (Discontinued)

What is the 1756-LSP?

The GuardLogix Safety Partner, the companion module that forms a safety controller pair with a GuardLogix 5560 controller.

Is it still available?

No. Rockwell discontinued it on 1 June 2017.

What replaces it?

1756-L7SP, which Rockwell lists as the functional replacement.

What is the UPC?

612598321735.

Does it have a network port?

No. Rockwell lists no embedded network port for the 1756-LSP.

Which battery does it use?

1756-BA2.

Does replacing it need re-validation?

Yes. The partner is part of the safety signature of the pair, so the configuration is re-validated after the swap.

Can a standard module be fitted instead?

No. A standard module removes the pair and with it the safety function.


Data sources. Technical values on this page come from Rockwell publications product page for 1756-LSP (lifecycle status, discontinuation date, functional replacement, UPC, battery, network port) and the manufacturer's product page for 1756-LSP. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)