Product Details:
Payment & Shipping Terms:
|
The 1756-LSP (also written 1756LSP) is the GuardLogix Safety Partner: the companion module that turns a GuardLogix 5560 safety controller into a controller pair in the chassis. Rockwell discontinued it on 1 June 2017 and lists the 1756-L7SP as the functional replacement.
The published product data is short and specific: UPC 612598321735, no embedded network port, the 1756-BA2 as the replacement battery, and a one-year standard warranty. There is no program in the safety partner — the safety task lives with the controller it is paired to — which is why the replacement is a safety-system change rather than a module swap.
1756-LSP |
GuardLogix Safety Partner, discontinued 1 June 2017, UPC 612598321735 |
In stock |
1756-L7SP |
Current safety partner, functional replacement for 1756-LSP |
In stock |
1756-L61S |
GuardLogix 5560 safety controller, 5561 class |
In stock |
1756-L62S |
GuardLogix 5560 safety controller |
In stock |
1756-L63S |
GuardLogix 5560 safety controller |
In stock |
Application |
GuardLogix Safety Partner |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-LSP |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-LSP |
Mounting |
Chassis |
Number Of Channels |
1756-LSP |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Communication Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
In a GuardLogix 5560 system the safety architecture is a pair, not a single module: the controller and the safety partner are two cards in the chassis that together carry the safety task. The partner is what makes the pair, and without it the controller is not a GuardLogix safety controller.
That is why the 1756-LSP appears in panels that were built with 1756-L61S, L62S or L63S controllers. When a partner fails, the controller does not become a standard controller: the pair is incomplete, and the safety function is not available until the pair is whole again.
It is also why the part is searched for long after it stopped shipping. The installed base is real, the controllers are still in service, and the partner is the piece that fails quietly — a battery, a backplane contact — leaving a controller that looks healthy and a safety function that is not.
A safety partner is judged by the pair it belongs to, not by a display of its own. The rows below are the fields Rockwell publishes for this catalogue number.
| Indicator | State | Meaning and first action |
| Lifecycle | Discontinued 1 June 2017 | Rockwell advises removing references to it from new designs. |
| Replacement | 1756-L7SP (functional replacement) | A series change, so firmware and validation are part of the migration. |
| UPC | 612598321735 | Rockwell product page identifier. |
| Embedded network port | None | The network identity belongs to the controller or the communication module in the chassis. |
| Replacement battery | 1756-BA2 | The battery Rockwell lists for this module. |
| Program storage | None of its own | The safety task belongs to the paired controller; the partner carries the pair's safety state. |
| Warranty | 1 year standard | Rockwell standard warranty duration. |
| Slot | Next to its partner controller | The pair is configured as a pair; slot order is part of the project definition. |
Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.
The 1756-L7SP is the functional replacement Rockwell names. Because the safety partner belongs to the safety signature of the pair, replacing it means re-validating the configuration and re-recording the signature, not just seating a card.
Carry the battery across in the plan: 1756-BA2 is the listed battery, and a replacement partner with an aged battery is a second failure waiting for the next power cycle.
Where the whole 5560 pair is being replaced by a 5570 or 5580 GuardLogix system, the safety partner question disappears into the controller migration, and the validation work moves with it.
Do not substitute a standard ControlLogix module for a partner. The partner is part of the safety architecture; a standard module in that slot removes the pair and with it the safety function.
What is the 1756-LSP?
The GuardLogix Safety Partner, the companion module that forms a safety controller pair with a GuardLogix 5560 controller.
Is it still available?
No. Rockwell discontinued it on 1 June 2017.
What replaces it?
1756-L7SP, which Rockwell lists as the functional replacement.
What is the UPC?
612598321735.
Does it have a network port?
No. Rockwell lists no embedded network port for the 1756-LSP.
Which battery does it use?
1756-BA2.
Does replacing it need re-validation?
Yes. The partner is part of the safety signature of the pair, so the configuration is re-validated after the swap.
Can a standard module be fitted instead?
No. A standard module removes the pair and with it the safety function.
Data sources. Technical values on this page come from Rockwell publications product page for 1756-LSP (lifecycle status, discontinuation date, functional replacement, UPC, battery, network port) and the manufacturer's product page for 1756-LSP. Values re-checked 16 November 2026.