The 1756-L73SXT / 1756L73SXT is the GuardLogix 5570 safety controller built on the 5570 hardware: 8 MB of standard user memory with a separate 4 MB safety memory, one chassis slot, the 1 GB SD card in the slot, and the paired safety partner that turns a standard controller into a SIL 3 / PLe pair.
Published figures for the GuardLogix 5570 controllers are 0.98 MB I/O memory, 128,000 digital I/O maximum, 1756-ESMCAP energy storage module shipped installed, 800 mA at 5.1 V DC and 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, 30 V continuous basic isolation from the USB port to the system, and a shipping weight of 0.25 kg (0.55 lb) (1756-TD001). The safety partner uses its own energy storage module — 1756-SPESMNSE or 1756-SPESMNRM — which is a separate line on the same specification table.
| 1756-L71 | ControlLogix 5570 controller, 2 MB user memory | IN STOCK |
| 1756-L72 | ControlLogix 5570 controller, 4 MB user memory | IN STOCK |
| 1756-L73 | ControlLogix 5570 controller, 8 MB user memory | IN STOCK |
| 1756-L71S | GuardLogix 5570 safety controller, 2 MB / 1 MB safety | IN STOCK |
| 1756-L72S | GuardLogix 5570 safety controller, 4 MB / 2 MB safety | IN STOCK |
| 1756-L73S | GuardLogix 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SP | GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S | IN STOCK |
| 1756-L73XT | ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C | IN STOCK |
| 1756-L73SXT | GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety | IN STOCK |
| 1756-L7SPXT | GuardLogix-XT 5570 safety partner, pairs with L73SXT | IN STOCK |
Application |
Safety Programmable Logic Controller |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-L73SXT |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-L73SXT |
Mounting |
Chassis |
Number Of Channels |
1756-L73SXT |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Controller |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.
The XT GuardLogix pair exists for cold and hot extremes where a standard safety controller cannot be installed: unheated outdoor cabinets, cold stores, skid-mounted safety systems. The memory split is that of the L73S, so the safety task design does not change.
Every element of the certified assembly has to be XT: controller, partner, safety I/O, chassis and supply. A SIL 3 claim in an XT panel is documented from that assembly, not from the controller alone.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| RUN | Steady green | Controller is in Run mode. |
| FORCE | Off | No tags contain I/O force values, or forces are disabled. |
| FORCE | Steady yellow | I/O forces are enabled. A field wiring check made now is not valid. |
| FORCE | Flashing yellow | Forced addresses exist but forces are not enabled; enabling them applies every stored force at once. |
| OK | Off | No power applied to the controller. |
| OK | Flashing red | New controller that needs a firmware update, or a major fault on a controller in service. |
| OK | Steady red | Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable. |
| OK | Steady green | Controller operating normally. |
| Status display | TEST / PASS | Power-up tests running, then completed. |
| Status display | CHRG | Capacitor energy storage module charging; do not remove the ESM. |
| Status display | BUSY | I/O modules in the project are not yet fully powered. |
| Status display | No Project | Controller memory is empty; download the project or load it from the SD card. |
| Status display | Rev XX.xxx | Firmware major and minor revision currently installed. |
Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.
For a 5560 GuardLogix rack in an extreme-temperature panel, this pair is the functional replacement; the chassis and the safety I/O move to their XT equivalents in the same outage.
Rockwell publishes the GuardLogix-XT 5570 controllers alongside the standard range in 1756-TD001, so the two can be compared line by line before the order is placed.
What temperature range does the 1756-L73SXT cover?
The XT range: -25…+70 °C, against 0…60 °C for the standard GuardLogix 5570 controller. Chassis, I/O and supplies in the rack must be XT parts as well.
Which energy storage modules does it take?
1756-ESMCAPXT ships installed; 1756-ESMNSEXT and 1756-ESMNRMXT are the alternatives. The partner uses 1756-SPESMNSEXT or 1756-SPESMNRMXT.
Is the memory different from the standard L73S?
No — 8 MB standard memory and 4 MB safety memory, the same split as 1756-L73S (1756-TD001).
What is the current draw in a cold panel?
800 mA at 5.1 V DC and 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, the same published values as the standard GuardLogix 5570 controllers.
Which partner pairs with it?
1756-L7SPXT, the XT safety partner, in its own slot.
Can a standard L73S be used in the same panel?
Not for an XT-rated assembly. Mixing a standard controller into an XT rack lowers the rating to the lowest component in it.
How is firmware updated below 0 °C?
From the SD card at power-up (UPDT on the display) or over the USB port inside the panel; both devices share the XT rating, so the operation stays inside the published envelope.
What indicators does the controller show?
RUN, FORCE, SD and OK plus the four-character status display; the safety partner carries its own indicators and its own energy storage state.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L73SXT. Values re-checked 16 November 2026.