Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier Allen Bradley PLC 1756-L71S / 1756L71S supplier

Large Image :  Allen Bradley PLC 1756-L71S / 1756L71S

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L71S / 1756L71S

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $3038.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-L71S technical data PDF download GuardLogix 1756-L71S / 1756L71S 2 MB Safety Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L71S / 1756L71S is the GuardLogix 5570 safety controller built on the 5570 hardware: 2 MB of standard user memory with a separate 1 MB safety memory, one chassis slot, the 1 GB SD card in the slot, and the paired safety partner that turns a standard controller into a SIL 3 / PLe pair.

Published figures for the GuardLogix 5570 controllers are 0.98 MB I/O memory, 128,000 digital I/O maximum, 1756-ESMCAP energy storage module shipped installed, 800 mA at 5.1 V DC and 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, 30 V continuous basic isolation from the USB port to the system, and a shipping weight of 0.25 kg (0.55 lb) (1756-TD001). The safety partner uses its own energy storage module — 1756-SPESMNSE or 1756-SPESMNRM — which is a separate line on the same specification table.

1756-L71 ControlLogix 5570 controller, 2 MB user memory IN STOCK
1756-L72 ControlLogix 5570 controller, 4 MB user memory IN STOCK
1756-L73 ControlLogix 5570 controller, 8 MB user memory IN STOCK
1756-L71S GuardLogix 5570 safety controller, 2 MB / 1 MB safety IN STOCK
1756-L72S GuardLogix 5570 safety controller, 4 MB / 2 MB safety IN STOCK
1756-L73S GuardLogix 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SP GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S IN STOCK
1756-L73XT ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C IN STOCK
1756-L73SXT GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SPXT GuardLogix-XT 5570 safety partner, pairs with L73SXT IN STOCK

 Application
 Safety Programmable Logic Controller
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L71S
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-L71S
 Mounting
 Chassis
 Number Of Channels
 1756-L71S
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L71S safety controller product photograph 1756-L71S controller, second view product photograph 1756-L71S controller label product photograph

Where the module sits in a typical system

1 MB of safety memory is sized for the safety task itself: the interlocks, the zone logic and the safety I/O configuration. The standard memory carries everything else, which is why the pair is bought as a pair — the non-safety program does not consume the safety budget.

A SIL 3 zone is a hardware decision as much as a software one: the controller, the partner, the safety I/O and the wiring all belong to the certified assembly, and the safety signature recorded in the project is what proves the installed logic matches the validated logic.

Commissioning in five steps

  1. Confirm the chassis supply budget before insertion: every 5570 controller draws 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC, so a rack that was planned around a 5560 controller has headroom, and a rack planned tight does not.
  2. Read the four-character status display at power-up before touching anything: TEST then PASS is a completed self-test, CHRG is the capacitor energy storage module charging, and any message other than PASS belongs in the fault log, not in a re-seat.
  3. The controller ships with a 1756-ESMCAP energy storage module already installed and with a 1 GB 1784-SD1 card in the slot. Both are removable, and a controller that will be shipped or stored needs the residual energy question answered before the ESM comes out.
  4. Load the project only after the firmware revision matches the project, then check the SD indicator: a LOAD or UPDT message means the card is being read at power-up and the card must stay in until the display clears.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 RUN  Steady green  Controller is in Run mode.
 FORCE  Off  No tags contain I/O force values, or forces are disabled.
 FORCE  Steady yellow  I/O forces are enabled. A field wiring check made now is not valid.
 FORCE  Flashing yellow  Forced addresses exist but forces are not enabled; enabling them applies every stored force at once.
 OK  Off  No power applied to the controller.
 OK  Flashing red  New controller that needs a firmware update, or a major fault on a controller in service.
 OK  Steady red  Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable.
 OK  Steady green  Controller operating normally.
 Status display  TEST / PASS  Power-up tests running, then completed.
 Status display  CHRG  Capacitor energy storage module charging; do not remove the ESM.
 Status display  BUSY  I/O modules in the project are not yet fully powered.
 Status display  No Project  Controller memory is empty; download the project or load it from the SD card.
 Status display  Rev XX.xxx  Firmware major and minor revision currently installed.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

For a 5560 GuardLogix rack the functional replacement path is this controller plus a 1756-L7SP, with the same chassis and the same safety I/O modules. The program is re-validated because the safety task, the signature and the firmware revision all change.

Inside the family the step up is the 1756-L72S (4 MB / 2 MB) or 1756-L73S (8 MB / 4 MB) with the identical partner, so a memory increase does not change the safety architecture.

Which ControlLogix 5570 controller to specify

  • 1756-L71 — 2 MB. Entry point of the 5570 range; the memory size that fits a single machine or a small line with no motion.
  • 1756-L72 — 4 MB. The usual minimum for a line controller with an HMI, produced/consumed tags and some recipe data.
  • 1756-L73 — 8 MB. The volume part of the family and the size most 5570 racks are built around.
  • 1756-L71S / L72S / L73S — GuardLogix versions with a separate safety memory (1 / 2 / 4 MB) alongside the standard memory.
  • 1756-L7SP — the safety partner that pairs with a GuardLogix 5570 controller to reach SIL 3 / PLe.
  • 1756-L73XT / L73SXT / L7SPXT — the same controllers and partner in the XT range for -25…+70 °C panels.

FAQ — GuardLogix 1756-L71S / 1756L71S 2 MB Safety Controller

How much memory does the 1756-L71S have?

2 MB of standard user memory and 1 MB of safety memory, with 0.98 MB of I/O memory and a 128,000 digital I/O maximum (1756-TD001, GuardLogix 5570 Controllers).

Does it need a safety partner?

Yes. The GuardLogix 5570 architecture pairs a GuardLogix controller with a 1756-L7SP safety partner to reach SIL 3 / PLe; the partner is a separate catalogue number and a separate slot.

Which energy storage modules apply to the pair?

The controller takes 1756-ESMCAP, ESMNSE or ESMNRM; the safety partner takes 1756-SPESMNSE or 1756-SPESMNRM. Both are listed on the GuardLogix 5570 specification table in 1756-TD001.

What programming languages does the safety task allow?

Ladder Diagram only for the safety task. Standard tasks in the same controller support Ladder Diagram, Structured Text, Function Block Diagram and Sequential Function Chart.

What is the current draw of the controller?

800 mA at 5.1 V DC and 5 mA at 1.2 V DC, with 2.5 W power dissipation and 8.5 BTU/hr, the same as the standard 5570 controllers (1756-TD001).

What does the shipping weight tell me?

0.25 kg (0.55 lb) is the published weight of the GuardLogix 5570 controller, which matters for spare-parts stock and air freight, not for panel loading.

Which SD card ships with it?

A 1 GB 1784-SD1 card, pre-installed. The card carries the project image; the display shows SAVE, LOAD or UPDT while it is in use.

Can a standard 5570 controller be converted to GuardLogix?

No. The safety memory and the safety-task capability are controller-specific; a GuardLogix pair is ordered as controller plus partner, and the safety signature is generated in the project.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L71S. Values re-checked 16 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)