Allen Bradley PLC 1756-OF8H / 1756OF8H

China Allen Bradley PLC 1756-OF8H / 1756OF8H supplier
Allen Bradley PLC 1756-OF8H / 1756OF8H supplier Allen Bradley PLC 1756-OF8H / 1756OF8H supplier Allen Bradley PLC 1756-OF8H / 1756OF8H supplier Allen Bradley PLC 1756-OF8H / 1756OF8H supplier Allen Bradley PLC 1756-OF8H / 1756OF8H supplier

Large Image :  Allen Bradley PLC 1756-OF8H / 1756OF8H

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OF8H / 1756OF8H

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: 1369.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OF8H technical data PDF download 1756-OF8H / 1756OF8H HART Analog Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OF8H (also written 1756OF8H) is the ControlLogix eight-channel voltage/current analog output module with a HART modem. Each channel can be configured as ±10 V, 0…20 mA or 4…20 mA, at 15…16 bit resolution, and the card carries one HART modem that serves all eight loops.

It is the module for plants that already run HART instruments: an analog output that can also carry digital HART data lets a positioner be commissioned and diagnosed from the programming software without a separate handheld, and it keeps the 4…20 mA signal as the primary control path.

1756-OF8H
8 voltage/current outputs, one HART modem
In stock
1756-OF8IH
8 isolated HART current outputs
In stock
1756-OF8I
8 isolated voltage/current outputs
In stock
1756-OF6CI
6 isolated current outputs
In stock
1756-IF8H
8 HART analog inputs where the loop is read
In stock

 Application
 HART voltage/current analog output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OF8H
 Type
 Analog output module with HART
 Sub Brand
 ControlLogix
 Mounting
 1756 ControlLogix chassis
 Number Of Channels
 8 voltage or current outputs, one HART modem per module
 Output Range
 ±10 V, 0…20 mA, 4…20 mA
 Resolution
 15…16 bits for all ranges
 Backplane Current
 230 mA at 5.1 V DC, 230 mA at 24 V DC
 Backplane Power
 6.54 W total
 Power Dissipation
 4.92 W
 Thermal Dissipation
 16.78 BTU/hr
 Isolation Voltage
 50 V basic, channels to backplane
 Channel Isolation
 None between output channels
 Overvoltage Protection
 ±24 V DC
 Settling Time (Current)
 < 23 ms without HART, < 37 ms with HART, 95%
 Settling Time (Voltage)
 < 8.5 ms to 95%
 Load Reactance
 1 µF voltage, 10 µH current
 Operating Temperature
 0…60 °C (32…140 °F)
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OF8H HART analog output module product photograph 1756-OF8H, second view product photograph 1756-OF8H, third view product photograph

Where a HART output module sits in the loop

HART on an output module is not the same product as HART on an input. On the input side each channel has its own modem because every transmitter talks back; here one modem per module is published, so the card multiplexes. In practice that means HART diagnostics on eight positioners are collected in sequence, and the time per loop grows with the number of instruments enabled.

The settling times make the trade explicit: under 23 ms to 95% for a current step without HART, under 37 ms with HART enabled, and under 8.5 ms for a voltage step. A loop that is retuned every 100 ms is unaffected; a fast hydraulic axis is being asked to wait for a modem handshake.

Isolation is 50 V basic from output channels to the backplane and none between channels. That is a deliberate design point rather than a limitation to be worked around: eight loops on one card share their return, and if the field devices sit on different grounded supplies, the card is the wrong choice — the isolated OF8I or OF6CI is the right one.

Open-circuit detection applies to current mode only and requires the channel to be commanded below 0.1 mA to be seen. This is the detail behind the common complaint that an unloaded current output reads normal: the card is not looking for an open circuit while it is driving 12 mA.

Voltage mode has a 1 µF load reactance limit, current mode 10 µH. Both are low enough that cable capacitance and input filters matter — an output that oscillates on a step is usually a load outside these limits rather than a faulty module.

The integer counts are published, which matters for programs that avoid floating point: 0…20 mA spans -32,768 to 32,767 counts between 0 mA and 21.2916 mA, and ±10 V spans the same counts between -10.4336 V and 10.4336 V.

Commissioning in five checks

  1. Plan for one HART modem, not eight. The module publishes a single modem for the whole card, so HART polling of several positioners is sequential and the update rate per loop is shared.
  2. Expect the HART settling time. Current outputs settle in under 23 ms without HART and under 37 ms with it — the difference is the modem handshake, and it shows up as a slower response on a fast positioning loop.
  3. Treat channel isolation honestly. Isolation is 50 V basic from channels to backplane and none between channels, so loops sharing a grounded field supply must be planned as one electrical group, unlike the isolated OF8I or OF6CI.
  4. Check the voltage-mode load reactance. A 1 µF limit in voltage mode is low: a long capacitive cable run or an input filter can exceed it, and the output will show overshoot or oscillation rather than a clean step.
  5. Use the published counts if the program works in integers. 0…20 mA maps to -32,768 counts at 0 mA and 32,767 at 21.2916 mA; ±10 V maps to those counts at -10.4336 V and 10.4336 V.

One modem, no channel isolation, and the limits that follow

Three indicators show the module state and HART traffic; the loop faults that matter are an undetected open circuit, a capacitive load, and a shared field common.

 Indicator  State  Meaning and first action
 OK  Green  Module healthy and exchanging data on the backplane.
 HART  Flashing  HART traffic on the module's single modem; several loops polled in turn.
 Current loop, no output  —  Open circuit detection applies to current mode only and requires the output to be set below 0.1 mA.
 Voltage output oscillation  —  Load capacitance above the published 1 µF limit; shorten the cable or remove the filter.
 All channels drift together  —  Single backplane supply and no channel-to-channel isolation: check the field common before the module.

Output, HART and settling figures per Rockwell publication 1756-TD002N-EN-E; configuration per 1756-UM533 and 1756-IN050.

Replacing a HART analog output module

HART faults are rarely module faults. Check the loop wiring and the instrument's HART address before replacing a card, because a single modem serving eight loops will report the first failing loop it polls.

A channel that will not detect an open circuit is behaving as published unless it is commanded below 0.1 mA; verify the command before ordering a replacement.

The module uses the 1756-TBCH or 1756-TBS6H terminal block, so a replacement can reuse the existing wiring arm and terminations.

Which HART analog output module to specify

  • 1756-OF8H — eight voltage/current outputs with one HART modem on the module.
  • 1756-OF8IH — eight isolated HART current outputs with per-channel isolation.
  • 1756-OF8I — eight isolated voltage/current outputs without HART.
  • 1756-OF6CI — six isolated current outputs, channel-to-channel isolation at 250 V.
  • 1756-TBCH / 1756-TBS6H — terminal blocks used across the eight-channel output family.

FAQ — 1756-OF8H / 1756OF8H HART Analog Output Module

What is the 1756-OF8H?

A ControlLogix eight-channel voltage/current analog output module with a HART modem.

How many HART modems does it have?

One per module, shared by all eight channels.

What output ranges are available?

±10 V, 0…20 mA and 4…20 mA, at 15…16 bit resolution.

Is it isolated channel to channel?

No. Isolation is 50 V basic, channels to backplane, with no isolation between output channels.

What is the settling time?

Under 23 ms without HART and under 37 ms with HART for current; under 8.5 ms for voltage, to 95%.

What does it draw from the backplane?

230 mA at 5.1 V DC and 230 mA at 24 V DC, 6.54 W total, 4.92 W dissipation.

How is open-circuit detection configured?

It applies to current mode and requires the output to be set below 0.1 mA.

What are the load reactance limits?

1 µF in voltage mode and 10 µH in current mode.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - 1756-OF8H output, HART, settling and power data; 1756-UM533 (ControlLogix HART Analog I/O Modules User Manual) and the manufacturer's product page for 1756-OF8H. Values re-checked 16 November 2026.