The 1756-OF6VI is the six-channel isolated voltage output module: ±10.5 V per channel with 250 V point-to-point isolation.
Rockwell discontinued it on 31 March 2017, with Functional Replacement as the replacement category, and the current TD002 edition no longer carries its output table.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Analog output module |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-OF6VI |
Outputs |
6, isolated voltage outputs |
Output Range |
±10.5 V |
Isolation Voltage |
250 V, point to point |
Backplane Current |
Not published for this item in the current documentation set |
Power Dissipation |
Not published for this item in the current documentation set |
Lifecycle Status |
Discontinued |
Discontinued Date |
31 March 2017 |
Replacement Category |
Functional Replacement |
Publications |
1756-TD002 (earlier edition), 1756-IN035C-EN-P (October 2000) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The ±10.5 V range and point-to-point isolation are the two facts that still apply when this module turns up in a panel. Six channels, each floating against the others, is a different arrangement from the eight-channel modules that replaced it in the catalogue.
Point-to-point isolation matters when the field devices do not share a reference. Six independent channels can drive six isolated signal conditioners or six valve positioners with separate supplies, and a fault on one channel does not pull the others to a common potential. That is also why the wiring is heavier than on a common-reference module: every channel needs its own return.
The voltage-only output is the limitation to check first. A 4…20 mA loop cannot be driven from this module, so a current-loop device needs a signal converter or a different module. Engineers who inherit this part often discover that the loop devices downstream are already fed through converters that were installed for exactly that reason.
The catalogue status is settled: discontinued on 31 March 2017, with Functional Replacement as the replacement category. Spares are the only exact-fit option, which makes the installed base the real market for this part.
No backplane current or dissipation figure is published for the OF6VI in the current documentation set. Earlier editions carried an output table, but a value quoted from a superseded page cannot be checked against the current document, so this page does not carry one.
The installation instructions that still exist for this module are 1756-IN035C-EN-P, dated October 2000. They cover the mechanical installation and the terminal assignments, not the electrical budget, which is consistent with the module having left the technical data sheet years before it left the catalogue.
There are no per-channel diagnostics on this module; a drifting or stuck channel is traced through the field reference, not through the card.
| Indicator | State | Meaning and first action |
| Channel drift appears on one point only | — | Channels are isolated from each other; a single drifting point is usually a field wiring or transducer fault. |
Facts on this page come only from the Rockwell publications named above; anything they do not state is marked as not published and 1756-IN050.
Record the installed configuration before removal so the replacement can be mapped against it.
Verify the replacement category against the current Rockwell product page rather than against a distributor list.
Keep one spare of the original where the machine cannot be re-commissioned quickly.
What is the 1756-OF6VI?
A six-channel isolated voltage output module for ControlLogix.
What output range does it have?
±10.5 V.
Is it isolated?
Yes, 250 V point to point.
When was it discontinued?
31 March 2017.
Is there a replacement?
Functional Replacement is the replacement category.
Can it drive a 4…20 mA loop?
No, it is voltage output only.
What is its backplane current?
Not published for this item in the current documentation set.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (ControlLogix I/O modules specifications, earlier edition) and Rockwell product lifecycle data - 6-channel isolated voltage output, ±10.5 V, 250 V point-to-point isolation, discontinued 31 March 2017 and the manufacturer's product page for 1756-OF6VI. Values re-checked 16 November 2026.