Allen Bradley PLC 1756-OF6CI / 1756OF6CI

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OF6CI / 1756OF6CI

China Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier
Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier Allen Bradley PLC 1756-OF6CI / 1756OF6CI supplier

Large Image :  Allen Bradley PLC 1756-OF6CI / 1756OF6CI

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OF6CI / 1756OF6CI

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1369.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OF6CI technical data PDF download 1756-OF6CI / 1756OF6CI Isolated Current Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OF6CI (also written 1756OF6CI) is the ControlLogix six-channel isolated current output module: 0…20 mA and 4…20 mA ranges, channel-to-channel isolation at 250 V, and a drive capability of 0…1000 Ω with separate field terminations for the 0…550 Ω and 551…1000 Ω ranges.

It is the module to specify when the loops must not share a common. Design accuracy is better than 0.1% of range from 4…21 mA at 25 °C, module error is 0.6% of range, and the output stage is an R-ladder DAC with monotonicity and no missing codes — the properties that matter when a valve positioner is being stepped rather than swung.

1756-OF6CI
6 isolated current outputs, 0…1000 Ω
In stock
1756-OF6VI
6 isolated voltage outputs
In stock
1756-OF8
8 analog outputs, group isolated
In stock
1756-OF8IH
8 HART current outputs
In stock
1756-IF16
16 analog inputs where the loop is read rather than driven
In stock

 Application
 Isolated current analog output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OF6CI
 Type
 Analog output module
 Sub Brand
 ControlLogix
 Mounting
 1756 ControlLogix chassis
 Number Of Channels
 6 current outputs, channel-to-channel isolated
 Output Range
 0…20 mA, 4…20 mA
 Drive Capability
 0…1000 Ω, separate terminations for 0…550 Ω and 551…1000 Ω
 Resolution / Accuracy
 Better than 0.1% of range from 4…21 mA at 25 °C
 Module Error
 0.6% of range
 Settling Time
 < 2 ms to 95% of final value, resistive load
 Scan Time
 25 ms maximum floating point, 10 ms integer
 Short Circuit
 Electronically limited to 21 mA or less
 Overvoltage Protection
 24 V DC
 Isolation Voltage
 250 V continuous, basic, channel-to-backplane and channel-to-channel
 Backplane Current
 225 mA at 24 V DC for 0…550 Ω loads, 300 mA for 551…1000 Ω
 Backplane Power
 6.7 W for 0…550 Ω, 8.5 W for 551…1000 Ω
 Power Dissipation
 5.5 W / 6.1 W maximum
 Thermal Dissipation
 18.76 / 20.80 BTU/hr
 Terminal Block
 1756-TBNH or 1756-TBSH
 Operating Temperature
 0…60 °C (32…140 °F)

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OF6CI isolated current output module product photograph 1756-OF6CI, second view product photograph 1756-OF6CI, third view product photograph

Where an isolated current output sits in the loop

Per-channel isolation is the reason this module exists alongside the cheaper eight-channel OF8. Six loops at 250 V channel-to-channel let one card drive positioners on equipment fed from different supplies, or on a skid whose field wiring is separately grounded, without a common-mode path between loops.

The drive range is split deliberately. Loads of 0…550 Ω terminate on OUT and RTN; loads of 551…1000 Ω terminate on OUT and ALT, and the backplane draw rises from 225 mA to 300 mA at 24 V, with total power from 6.7 W to 8.5 W. A 750 Ω loop is not just a heavier load, it is a different terminal pair and a different power budget.

Protection is published rather than implied: overvoltage protection at 24 V DC and short-circuit protection electronically limited to 21 mA or less. On a 4…20 mA loop that 21 mA ceiling is above the 20 mA span, so a shorted loop reads over-range instead of damaging the output stage.

Timing is the constraint on the control side. Module scan is 25 ms maximum in floating point and 10 ms in integer, with settling under 2 ms to 95% of a step into a resistive load. A loop that is retuned every 100 ms at the controller is unaffected; a fast hydraulic positioner is not.

Accuracy has a shelf life. Calibrated accuracy of 0.1% is stated at 25 °C, with offset drift of 1 µA/°C and gain drift of 60 ppm/°C typical, 100 ppm/°C maximum, on a six-month calibration interval. The honest way to carry those numbers into a specification is to state the interval alongside the accuracy.

The terminal block choice is 1756-TBNH or 1756-TBSH, and the module draws one slot. The TBNH accepts two conductors per terminal at 0.33…1.3 mm², the TBSH one conductor at 0.33…2.1 mm² — the difference decides whether a loop and its shield drain can be landed on the same terminal.

Commissioning in five checks

  1. Terminate the field loop on the right pair of terminals. The module publishes separate terminations for 0…550 Ω and 551…1000 Ω loads, and the backplane draw changes between them — 225 mA versus 300 mA at 24 V.
  2. Keep the loop resistance inside 1000 Ω. Above that the module cannot drive the current, and the symptom is a loop that reads correct at zero percent and falls away at span.
  3. Set the loop supply correctly. Overvoltage protection is 24 V DC and the short-circuit limit is 21 mA, so a 24 V field supply with a 250 Ω sense resistor is inside the design envelope and a 32 V supply is not.
  4. Allow for the scan and settling: 25 ms in floating point, 10 ms in integer, with under 2 ms to 95% of a step. A valve positioner that expects a 5 ms update is being driven slower than the module can go.
  5. Book the calibration interval into maintenance. Six months typical with 1 µA/°C offset drift and 60 ppm/°C typical gain drift is a shelf-life statement, not a permanent accuracy guarantee.

Loop resistance, protection and accuracy over time

Two indicators cover the module itself; loop faults show up as a span error, a current pinned at 21 mA, or a slow drift that the calibration interval explains.

 Indicator  State  Meaning and first action
 OK  Green  Module healthy and communicating on the backplane.
 Loop reads low at span  —  Field resistance above 1000 Ω, or the loop terminated on the 0…550 Ω pair with a higher-resistance load.
 Output stuck at 21 mA  —  Short circuit protection has engaged; the loop is electronically limited to 21 mA or less.
 Drift over months  —  Offset 1 µA/°C typical, gain 60 ppm/°C typical; recalibrate on the published six-month interval.

Loop, isolation and accuracy figures per Rockwell publication 1756-TD002N-EN-E; configuration per 1756-UM009 and 1756-IN050.

Replacing an analog output module

A loop that reads low at span is usually field resistance, not the module: check the total loop resistance against the 1000 Ω limit and the terminal pair against the 550 Ω boundary.

An output pinned at 21 mA has short-circuit protection engaged; find the field short before replacing the card, or the replacement will do the same thing.

A channel that drifts while its neighbours hold points at a failed calibration rather than a failed DAC, which is why the six-month interval is published. Recalibrate before condemning the module.

Which analog output module to specify

  • 1756-OF6CI — six isolated current outputs with channel-to-channel isolation.
  • 1756-OF6VI — the voltage variant of the same six-channel module.
  • 1756-OF8 — eight outputs in one module, group isolation rather than per channel.
  • 1756-OF8IH — eight HART current outputs for smart transmitters and positioners.
  • 1756-TBNH / 1756-TBSH — the terminal blocks the OF6CI uses.

FAQ — 1756-OF6CI / 1756OF6CI Isolated Current Output Module

What is the 1756-OF6CI?

A ControlLogix analog output module with 6 isolated current outputs.

What ranges does it support?

0…20 mA and 4…20 mA.

What load can it drive?

0…1000 Ω, with separate terminations for 0…550 Ω and 551…1000 Ω loads.

Is it isolated channel to channel?

Yes — 250 V continuous, basic insulation, channel-to-backplane and channel-to-channel.

What is the accuracy?

Better than 0.1% of range from 4…21 mA at 25 °C; module error 0.6% of range.

What is the short-circuit behaviour?

The output is electronically current limited to 21 mA or less.

What does it draw from the backplane?

225 mA at 24 V DC for 0…550 Ω loads or 300 mA for 551…1000 Ω loads, 6.7 W or 8.5 W total.

What is the scan time?

25 ms maximum in floating point and 10 ms in integer mode, with settling under 2 ms to 95%.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - 1756-OF6CI output, isolation, power and environmental data; 1756-UM009 (ControlLogix Analog I/O Modules User Manual) and the manufacturer's product page for 1756-OF6CI. Values re-checked 16 November 2026.