Allen Bradley PLC 1756-OF4 / 1756OF4

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OF4 / 1756OF4

China Allen Bradley PLC 1756-OF4 / 1756OF4 supplier
Allen Bradley PLC 1756-OF4 / 1756OF4 supplier Allen Bradley PLC 1756-OF4 / 1756OF4 supplier Allen Bradley PLC 1756-OF4 / 1756OF4 supplier Allen Bradley PLC 1756-OF4 / 1756OF4 supplier Allen Bradley PLC 1756-OF4 / 1756OF4 supplier

Large Image :  Allen Bradley PLC 1756-OF4 / 1756OF4

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OF4 / 1756OF4

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $645.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OF4 technical data PDF download 1756-OF4 / 1756OF4 ControlLogix 4-Channel Analog Output

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OF4 (also written 1756OF4) is the ControlLogix 4-channel analog output module: four voltage or current outputs on ±10 V DC and 0…20 mA, with 15-bit resolution across 10.5 V (320 µV/bit) and 16-bit across 21 mA (325 nA/bit).

Two hardware series exist and they are not electrically identical. Series A draws 150 mA at 5.1 V and 120 mA at 24 V; series B draws up to 200 mA and 155 mA. Both figures are published and both appear on the module nameplate.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Analog output module
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OF4
 Outputs
 4 voltage or current
 Output Range
 ±10 V DC; 0…20 mA
 Resolution
 15 bits across 10.5 V = 320 µV/bit; 16 bits across 21 mA = 325 nA/bit
 Backplane Current, Series A
 150 mA @ 5.1 V; 120 mA @ 24 V
 Backplane Current, Series B
 200 mA max @ 5.1 V; 155 mA max @ 24 V
 Backplane Power
 3.7 W (series A); 4.74 W max (series B)
 Power Dissipation
 3.7 W at 0…750 Ω (series A); 4.74…1.74 W (series B)
 Thermal Dissipation
 10.91 BTU/hr (series A); 16.17 BTU/hr (series B)
 Isolation
 None between channels (single-ended)
 Overvoltage Protection
 24 V DC
 Open Circuit Detection
 Current mode only, output must be set above 0.1 mA
 Terminal Block
 1756-TBNH or 1756-TBSH, 20-position
 RTB Torque
 0.8…1 N·m (7…9 lb·in)
 Wire Size
 #22…14 AWG (0.324…2.08 mm²), 1.2 mm insulation max
 Slot Width
 1

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OF4 analog output module product photograph 1756-OF4, second view product photograph 1756-OF4, third view product photograph

Where the module sits on an analog loop

The series difference is the first thing to check on a replacement. Series A total backplane power is 3.7 W with 10.91 BTU/hr dissipation; series B is 4.74 W with 16.17 BTU/hr. In a chassis already close to its supply limit, a series B module in a slot budgeted for series A is the difference between running and browning out.

There is no isolation between channels — the module is single-ended. Four loops share a reference, and a grounded transducer on one channel introduces an error on the others. Where that matters, the 6-channel isolated modules (OF6VI, OF6CI) or the 8-channel OF8I are the alternatives.

Open circuit detection exists but is conditional: it applies to current mode only, and the output must be commanded above 0.1 mA for the diagnostic to report anything. A loop configured at 0 mA has no useful open-circuit indication, which is a common commissioning surprise.

Field wiring is through a 20-position removable terminal block, 1756-TBNH or 1756-TBSH. The block is not included with the module. RTB keying is user defined on this module, so a block keyed for another module family will not seat properly and the module will not appear in the chassis.

Terminations are specified in the installation instructions: 0.8…1 N·m (7…9 lb·in) on the screw block, conductors #22…14 AWG (0.324…2.08 mm²), and no more than 1.2 mm of insulation stripped. These are tighter than the general ControlLogix ranges used on the 16- and 32-point digital families.

Output range is ±10 V or 0…20 mA, with overvoltage protection to 24 V DC. Because the resolution figures differ between the two modes, the effective step size depends on which mode the channel is configured for — 320 µV in voltage mode, 325 nA in current mode.

Commissioning in five checks

  1. Confirm the hardware series before ordering. Series A and B differ by 50 mA on the 5.1 V rail and about 1 W of backplane power, which matters in a chassis close to its supply limit.
  2. Fit a 20-position RTB, 1756-TBNH or TBSH. It is not supplied with the module, and the two blocks are not interchangeable with the 16-point families.
  3. Torque the screw RTB to 0.8…1 N·m. The range comes from the installation instructions, not from a generic terminal block rule.
  4. Strip no more than 1.2 mm of insulation and keep to #22…14 AWG. A heavier conductor will not fit the 20-position block.
  5. Set the output above 0.1 mA before relying on open circuit detection, and remember that there is no channel-to-channel isolation to lean on in a noisy loop.

Loop faults and what the module reports

This module reports module health and calibration state only; an open circuit needs current mode above 0.1 mA, and channel-to-channel errors are not flagged because there is no isolation between them.

 Indicator  State  Meaning and first action
 Channel reads a fixed offset after a module swap  —  Series A and B are electrically different: 150 mA versus 200 mA on 5.1 V and 3.7 W versus 4.74 W total backplane power. A chassis sized for one may not supply the other.
 Output drifts between channels  —  There is no isolation between channels on this module; a shared return path carries the error across all four.
 Module does not appear in the chassis after insertion  —  RTB keying is user defined on the 20-position block; a block keyed for another module type will not seat correctly.

Resolution, backplane current, dissipation and isolation per Rockwell publication 1756-TD002-EN-E; RTB torque and wire size per 1756-IN016 and 1756-IN050.

Replacing a 1756-OF4

Check the hardware series on the old module before ordering the replacement; series A and B differ in backplane current and power.

Carry the 20-position RTB over or fit a new TBNH/TBSH, and re-key it for the module.

Re-verify the current-mode channels are above 0.1 mA if open circuit detection was relied on.

Which analog output module to specify

  • 1756-OF4 — 4 voltage or current outputs, no channel-to-channel isolation.
  • 1756-OF6VI / OF6CI — 6 individually isolated channels, voltage or current respectively.
  • 1756-OF8 — 8 outputs in one slot.
  • 1756-OF8H — 8 outputs plus a HART modem for field instrument diagnostics.
  • 1756-IF8 / IF16 — the input-side counterparts with the same terminal block family.

FAQ — 1756-OF4 / 1756OF4 ControlLogix 4-Channel Analog Output

What is the 1756-OF4?

A ControlLogix 4-channel analog output module with four voltage or current outputs.

What are the output ranges?

±10 V DC and 0…20 mA.

What resolution does it offer?

15 bits across 10.5 V (320 µV/bit) in voltage mode and 16 bits across 21 mA (325 nA/bit) in current mode.

What is the difference between series A and series B?

Backplane current and power: series A draws 150 mA at 5.1 V and 120 mA at 24 V with 3.7 W; series B draws up to 200 mA and 155 mA with 4.74 W.

Are the channels isolated from each other?

No, there is no isolation between channels.

Which terminal block does it use?

A 20-position 1756-TBNH or 1756-TBSH, not supplied with the module.

What torque should the RTB screws be set to?

0.8…1 N·m (7…9 lb·in).

When does open circuit detection work?

In current mode only, with the output set above 0.1 mA.

What wire size fits the terminal block?

#22…14 AWG (0.324…2.08 mm²), 1.2 mm insulation maximum.

How much heat does it dissipate?

10.91 BTU/hr for series A, 16.17 BTU/hr for series B.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (ControlLogix I/O Modules Specifications) - OF4 series A and series B electrical tables; 1756-IN016 (ControlLogix Voltage/Current Output Module 1756-OF4 installation instructions) - RTB torque, wire size, keying and the manufacturer's product page for 1756-OF4. Values re-checked 16 November 2026.