logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OB8EI / 1756OB8EI

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OB8EI / 1756OB8EI

China Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier
Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier Allen Bradley PLC 1756-OB8EI / 1756OB8EI supplier

Large Image :  Allen Bradley PLC 1756-OB8EI / 1756OB8EI

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB8EI / 1756OB8EI

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $325.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-OB8EI technical data PDF download 1756-OB8EI ControlLogix 8 Point Isolated DC Output Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB8EI (also written 1756OB8EI) is the 8-point DC output module with output-to-output isolation: 10...30 V DC, 2 A pilot duty (DC-13/S0), 10 A at 60 °C and 16 A at 55 °C maximum per module, backplane 250 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 250 V basic output-to-output (1756-IN062).

The module total is remarkable for eight channels: 10 A at 60 °C and 16 A at 55 °C. That is twice the OB8's allowance, which means this card is not limited by eight points at 2 A but by the thermal envelope — and the envelope widens as the cabinet gets cooler.

Each output is isolated from its neighbours at 250 V, so eight separate circuits can share one module without a common return. That is the feature the plain OB8 lacks, and it is what makes the OB8EI the right card for a mixed-supply panel with a short output list.

Backplane draw is 250 mA at 5.1 V DC — more than the OB8's 165 mA, which is the cost of the individual output barriers.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB8EI
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 8
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB8EI module product photograph 1756-OB8EI label product photograph 1756-OB8EI terminal side product photograph

Where the module sits in a typical system

This is the card for eight outputs that must not share a return: separate 24 V supplies, mixed field circuits, or a machine where each actuator is fed by its own protective circuit.

Its 10 A module allowance at 60 °C also makes it useful where a few points carry heavier DC loads than the channel count would suggest, provided each stays at or below 2 A.

Where all eight outputs share one supply, the OB8 is 85 mA lighter on the 5.1 V rail and equally capable at 2 A per point.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Eight separate barriers 250 V output-to-output on every point, not a group.
 Check 3 2 A pilot duty DC-13/S0 per point, with the module total well above eight times 2 A.
 Check 4 250 mA backplane The isolation costs 85 mA on the 5.1 V rail compared with the OB8.
 Check 5 T4 temperature code 135 °C maximum surface temperature, less restrictive than the T4A modules.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For eight outputs with a shared return, 1756-OB8 publishes the same 2 A pilot duty without output-to-output isolation.

For sixteen isolated points, 1756-OB16I carries 250 V reinforced to the backplane.

For 32 points at 500 mA, 1756-OB32 doubles the density.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB8EI ControlLogix 8 Point Isolated DC Output Module | Rockwell

What is the 1756-OB8EI?

An 8-point DC output module with 250 V output-to-output isolation, 10...30 V DC, 2 A pilot duty per point.

What is the module maximum current?

10 A at 60 °C and 16 A at 55 °C.

How is it isolated?

250 V continuous basic outputs-to-backplane and 250 V basic output-to-output.

Can each point be fed from a different supply?

Yes — each output has its own barrier, so separate supplies and returns are supported.

What is the backplane current?

250 mA at 5.1 V DC and 2 mA at 24 V DC.

What is the per-point current rating?

2 A pilot duty, DC-13/S0.

What is its temperature code?

T4, with 60 °C maximum surrounding air.

Which publication publishes the table?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB8EI. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)