Product Details:
Payment & Shipping Terms:
|
The 1756-OB8 (also written 1756OB8) is the 8-point DC output module: 10...30 V DC, 2 A pilot duty (DC-13/S0), 8 A maximum per module at 60 °C, backplane 165 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane with no isolation between individual outputs (1756-IN062).
Eight points at a genuine 2 A each is what this module offers, and the module total of 8 A at 60 °C means all eight can run at full rating simultaneously — an unusual allowance in a family where the module total usually binds before the per-point figure does.
The isolation is the limitation: 250 V to the backplane and nothing between outputs, so all eight share a return. Where separate returns are needed, the OB8EI publishes output-to-output isolation at the same channel count and current.
It is the short, single-group card for a small output list: eight contactor coils, valves or lamps on a machine section whose panel has room for only eight points and needs the full 2 A.
1756-IB16 | 16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 | In stock |
1756-IB16D | 16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA | In stock |
1756-IB16I | 16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA | In stock |
1756-IB16IF | 16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA | In stock |
1756-IB16ISOE | 16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA | In stock |
1756-IB32 | 32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 | In stock |
1756-IC16 | 16 inputs, 30...60 V DC, backplane per 1756-IN062 | In stock |
1756-IG16 | 16 TTL inputs, backplane per 1756-IN062 | In stock |
1756-IV16 | 16 inputs, 48 V DC, backplane per 1756-IN062 | In stock |
Application | Discrete output |
Brand Name | Rockwell (Rockwell) |
Cat Num | 1756-OB8 |
Communication | Backplane (producer/consumer) |
Display | — |
Enclosure | None (open-style) |
Interface | Removable terminal block |
Mounting | Chassis slot |
Number Of Channels | 8 |
Standard | CE, UL, CSA, RCM |
Sub Brand | ControlLogix |
Type | Digital Output Module |
UNSPSC | — |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The OB8 fits a compact machine section: eight 24 V DC contactor coils or solenoid valves, all from one supply, where a 16-point card would leave half its channels unused and half its backplane current wasted.
Because the module total equals eight times the point rating, the OB8 is also the honest way to get 2 A on every channel without derating arithmetic across sixteen points.
Where outputs must be isolated from each other, the OB8EI provides the same ratings with 250 V output-to-output.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 8 A module total at 60 °C | Exactly eight points at 2 A, so the per-point rating is fully usable. |
| Check 3 | 2 A pilot duty | DC-13/S0, the standard pilot duty rating for a DC output driving a contactor coil. |
| Check 4 | 165 mA backplane | Lower than the 16-channel cards, which makes the OB8 easy on a crowded chassis. |
| Check 5 | 1.36 N·m terminal torque | The 20-pin 1756-TBNH block, tightened to 1.36 N·m (12 lb-in) per IN062. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
For eight isolated outputs, 1756-OB8EI publishes 250 V output-to-output at the same 2 A pilot duty.
For sixteen points, 1756-OB16I covers 2 A pilot duty with 250 V reinforced isolation.
For 32 points at 500 mA, 1756-OB32 doubles the density.
What is the 1756-OB8?
An 8-point DC output module, 10...30 V DC, 2 A pilot duty, 8 A module maximum at 60 °C.
Are the outputs isolated from each other?
No. There is 250 V basic isolation to the backplane and none between individual outputs.
Can all eight points carry 2 A?
Yes — the module total is 8 A at 60 °C, which is eight points at the full rating.
What is the backplane current?
165 mA at 5.1 V DC and 2 mA at 24 V DC.
What terminal block does it use?
The 20-pin 1756-TBNH (or TBSH), torqued to 1.36 N·m (12 lb-in).
What is the temperature code?
T4A under the North American classification.
Can it drive a contactor coil?
Yes, at 2 A pilot duty DC-13/S0, with suppression fitted across the coil.
Which publication should be quoted?
1756-IN062 for the ratings and RTB table.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB8. Values re-checked 15 November 2026.