Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS

China Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier
Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS supplier

Large Image :  Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB16IEFS / 1756OB16IEFS

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $719.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-OB16IEFS technical data PDF download 1756-OB16IEFS ControlLogix 16 Point Fast Isolated DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB16IEFS (also written 1756OB16IEFS) is the 16-point fast DC output module with output-to-output isolation: 10...30 V DC, 2 A per channel at 45 °C on four channels maximum, 1 A at 60 °C, backplane 320 mA at 5.1 V DC and 3 mA at 24 V DC, isolation 250 V continuous reinforced outputs-to-backplane and 250 V basic output-to-output (1756-IN062).

It is the OB16IEF's power stage with the isolation barrier added: same four-channel limit at 2 A, same 1 A ceiling at 60 °C, same 320 mA on the 5.1 V rail — plus 250 V reinforced to the backplane and 250 V between outputs.

That combination is what a panel needs when the fast outputs also drive circuits that must stay separated. Separate 24 V supplies feeding different points are allowed inside the 250 V barrier, and each output stands apart from its neighbours rather than sharing a common return inside a group.

The design discipline is unchanged: four channels get 2 A at 45 °C, everything else 1 A, and 1 A at 60 °C across the board. The isolation improves safety and topology, not the thermal rating.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB16IEFS
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB16IEFS module product photograph 1756-OB16IEFS label product photograph 1756-OB16IEFS terminal side product photograph

Where the module sits in a typical system

Use it where fast outputs and separated circuits occur together: a high-speed test station with several 24 V supplies, or a machine whose fast solenoid outputs must not share a return with the sensor circuits.

The 250 V reinforced backplane barrier also suits panels that mix 24 V DC control with higher-voltage field equipment in the same enclosure, where the chassis reference must stay isolated from the output circuits.

Where the outputs can share returns, the OB16IEF provides the same speed and current without the isolation premium.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 250 V reinforced The strongest barrier in the family, paired with 250 V output-to-output.
 Check 3 1 A at 60 °C Thermal ceiling for every channel at the maximum ambient.
 Check 4 320 mA backplane Same as the OB16IEF — the isolation is in the output stage, not an extra supply rail.
 Check 5 Suppression at the load Fast switching and unsuppressed coils are a poor pair; fit the diode or RC at the load.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For fast outputs without output-to-output isolation, 1756-OB16IEF publishes the same 2 A at 45 °C on four channels.

For 2 A pilot duty on every channel, 1756-OB16I carries a 350 mA backplane draw.

For 32 channels at 500 mA, 1756-OB32 doubles density at a 16 A module rating.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB16IEFS ControlLogix 16 Point Fast Isolated DC Output | Rockwell

What is the 1756-OB16IEFS?

A 16-point fast DC output module with 250 V reinforced isolation to the backplane, 10...30 V DC, 2 A at 45 °C on four channels and 1 A at 60 °C.

What is the difference from the OB16IEF?

The output and backplane ratings are the same; this catalog number publishes 250 V reinforced outputs-to-backplane and 250 V basic output-to-output.

How many channels can carry 2 A?

Four at 45 °C. The published note limits the 2 A rating to four channels.

What is the per-channel maximum at 60 °C?

1 A.

Can different points use separate supplies?

Yes, within the 250 V output-to-output barrier.

What is the backplane current?

320 mA at 5.1 V DC and 3 mA at 24 V DC.

What is the temperature code?

T4 under the North American classification in 1756-IN062.

Which publication should be quoted?

1756-IN062 for the ratings table.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16IEFS. Values re-checked 15 November 2026.