logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OB16I / 1756OB16I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OB16I / 1756OB16I

China Allen Bradley PLC 1756-OB16I / 1756OB16I supplier
Allen Bradley PLC 1756-OB16I / 1756OB16I supplier Allen Bradley PLC 1756-OB16I / 1756OB16I supplier Allen Bradley PLC 1756-OB16I / 1756OB16I supplier Allen Bradley PLC 1756-OB16I / 1756OB16I supplier Allen Bradley PLC 1756-OB16I / 1756OB16I supplier

Large Image :  Allen Bradley PLC 1756-OB16I / 1756OB16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB16I / 1756OB16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $378.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OB16I technical data PDF download 1756-OB16I ControlLogix 16 Point Isolated DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB16I (also written 1756OB16I) is the 16-point isolated DC output module: 24 V DC, 2 A pilot duty (DC-13/S0), published over 10...30 V DC for ATEX/IECEx applications, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC, isolation 250 V continuous reinforced outputs-to-backplane and 250 V basic output-to-output (1756-IN062).

Its minimum load is a real constraint: 8 A at 30 °C falling to 4 A at 60 °C by linear derating. That is the total the module can carry, not a per-point figure — sixteen points at 2 A each would be 32 A and the module will not deliver it.

The isolation pair is the highest in the DC output family: reinforced to the backplane at 250 V and basic output-to-output at 250 V. Where one module drives outputs that reference different supply returns, or where the field circuit must stay separated from the chassis, this is the arrangement that allows it.

The module is part of the family that publishes per-point fault and program states, electronic module keying and removal under power, and it is configured in the Studio 5000 project rather than by hardware jumpers. Its backplane draw at 5.1 V DC, 350 mA, is the highest of the 16-point DC outputs.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB16I module product photograph 1756-OB16I label product photograph 1756-OB16I terminal side product photograph

Where the module sits in a typical system

The OB16I is the general-purpose 24 V DC output for contactor coils, solenoid valves, indicator lamps and small DC drives where 2 A per point is enough and the total stays inside the derated module figure.

Its reinforced isolation suits panels that mix 24 V DC control with other field references, and its output-to-output barrier allows groups of points to be fed from separate 24 V supplies without a common return.

Where the panel needs point-level load diagnostics, the OB16D compares measured output to commanded state; where the load is faster than a standard card can switch, the IEF or IEFS fast-output modules are the published alternatives.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  24 V DC nominal  Published at 24 V DC for the standard module, with a 10...30 V DC range quoted for the ATEX/IECEx rating.
 Check 3  Reinforced to the backplane  250 V reinforced, plus 250 V basic output-to-output — the strongest isolation in the family.
 Check 4  350 mA backplane  Half the 5.1 V DC budget of a 16-point card goes here; count it before populating a slot with several I/O modules.
 Check 5  Unsolicited suppression  An inductive load needs its own suppression. The output stage is rated, not indestructible.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 32 points at 500 mA per channel, 1756-OB32 covers twice the density at a 16 A module rating.

For electronic fusing and load diagnostics, 1756-OB16D publishes 2 A at 30 °C and 1 A at 60 °C.

For isolating individual outputs at 250 V with 2 A, 1756-OB8EI is the 8-point equivalent.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB16I ControlLogix 16 Point Isolated DC Output | Rockwell

What is the 1756-OB16I?

A 16-point isolated 24 V DC output module, 2 A pilot duty per point, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC.

What is the module's total current?

8 A at 30 °C, derating linearly to 4 A at 60 °C. That is the module ceiling, not a per-point figure.

What isolation does it provide?

250 V continuous reinforced outputs-to-backplane and 250 V basic output-to-output.

What output voltage does it switch?

24 V DC, published over 10...30 V DC for ATEX/IECEx applications.

How much backplane current does it draw?

350 mA at 5.1 V DC and 2.5 mA at 24 V DC.

Can it drive sixteen contactors at 2 A?

Only to the module total. At 30 °C that is 8 A, so four points at 2 A, not sixteen.

Does it monitor the load?

Not by itself — the load-diagnostic module in this family is the 1756-OB16D.

What is the maximum surrounding air temperature?

60 °C, with a 60 °C maximum surrounding air rating published for the family.

Which publication has the full table?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)