Product Details:
Payment & Shipping Terms:
|
The 1756-M02AS (also written 1756M02AS) is the two-axis analog servo module with SSI absolute feedback: the same ±10 V command reference as the 1756-M02AE, with a synchronous serial interface input at 8 to 31 bits instead of an incremental encoder channel.
Published figures are 2 axes per module, SSI resolution 8…31 bits, absolute position to 2³² (4,294,967,296) transducer counts, selectable rates of 500 Hz, 666.7 Hz, 1 kHz, 2 kHz and 4 kHz, 700 mA at 5.1 V DC and 2.5 mA at 24 V DC, 5.5 W and 18.77 BTU/hr, 30 V continuous user-to-system isolation, and the 1756-TBS6H spring-clamp terminal block (1756-TD004).
| 1756-M02AE | 2-axis analog servo module, incremental quadrature feedback | IN STOCK |
| 1756-M02AS | 2-axis analog servo module, SSI absolute feedback 8…31 bits | IN STOCK |
| 1756-HYD02 | 2-axis analog hydraulic servo module, LDT feedback | IN STOCK |
| 1756-M03SE | SERCOS module, 3 drives, position / velocity / torque | IN STOCK |
| 1756-M08SE | SERCOS module, 8 drives, position / velocity / torque | IN STOCK |
| 1756-M16SE | SERCOS module, 16 drives, position / velocity / torque | IN STOCK |
| 1756-M08SEG | SERCOS module, 8 Extended Pack Profile drives, position only | IN STOCK |
Application |
Analog servo interface motion |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-M02AS |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-M02AS |
Mounting |
Chassis |
Number Of Channels |
1756-M02AS |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Motion control module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Absolute feedback is what makes a machine keep its position through a power cycle or a stop: the axis does not re-home, because the transducer reports position rather than counting pulses. That is the reason a press transfer, a tool changer or a rotary table is built on the M02AS rather than on the incremental module.
The published range is 2³² transducer counts, so the absolute position figure is far beyond any real machine's stroke; the practical limit is the SSI word length the transducer provides and the rate at which the module samples it.
These are the published signal levels and limits of the module — the figures to measure against at the terminals and in the axis configuration, taken from 1756-TD004 rather than from a generic commissioning checklist.
| Indicator | State | Meaning and first action |
| Servo output | ±10 V, 16-bit | Analog command reference with 25 mV maximum offset, ±4% gain error and a minimum 5.6 kΩ resistive load. |
| Registration input | 24 V DC, current sinking | On-state 18.5…26.4 V DC, off-state 3.5 V DC maximum; 5 V input variant on-state 3.7…5.5 V DC. |
| Relay output | 24 V DC, 75 mA | Solid-state isolated relay contact, 26.4 V DC maximum, Class 2 source. |
| Isolation | 30 V continuous | User terminals to system, the figure to quote when the panel is shared with other equipment. |
| Slot load | 700 mA at 5.1 V DC | Plus 2.5 mA at 24 V DC, 5.5 W and 18.77 BTU/hr per module. |
| Terminal block | %s | Screw torque 0.4 N·m (4.4 lb·in), screwdriver width 8 mm maximum. |
| SSI resolution | 8…31 bits | Resolution below the machine's positioning requirement is the usual cause of a loop that never settles; check the transducer word length against the axis. |
| Transducer rate | 500 Hz / 666.7 Hz / 1 kHz / 2 kHz / 4 kHz | Selectable, against the fixed 5 kHz of the M02AE; the absolute device sets the ceiling. |
Signal levels, loop rates, rates and terminal block data per Rockwell publication 1756-TD004B-EN-E (1756 ControlLogix Integrated Motion Modules Specifications) and 1756-IN050.
Where the machine needs absolute position, the M02AS is the analog family's answer; where the drive has moved to a digital interface, the equivalent axes are carried by a SERCOS module and the SSI wiring is reduced to a fibre pair.
The module shares the slot, the load and most of the wiring with the M02AE: 700 mA at 5.1 V DC, 5.5 W, 30 V isolation and the same 2-axes-per-module limit.
What feedback does the 1756-M02AS take?
SSI, synchronous serial interface, isolated 5 V differential (RS-422 signal), 8…31 bit resolution, 215 Ω differential input impedance (1756-TD004).
How many axes per module?
Two, and multiple modules bring one ControlLogix controller to as many as 32 axes.
What update rates are selectable?
500 Hz, 666.7 Hz, 1 kHz, 2 kHz and 4 kHz, against the fixed 5 kHz of the 1756-M02AE.
What is the absolute position range?
2³² (4,294,967,296) transducer counts, with gain resolution at 32-bit floating point.
Which terminal block is used?
1756-TBS6H, the 36-pin spring-clamp block; 0.4 N·m screw torque where screws are used, 8 mm maximum screwdriver width.
What is the chassis load?
700 mA at 5.1 V DC, 2.5 mA at 24 V DC, 5.5 W dissipation and 18.77 BTU/hr thermal load.
Does it isolate the transducer from the system?
30 V continuous, user to system, the same figure as the other analog motion modules.
Which loop type does it run?
A PID position loop with velocity feed-forwards and a PI velocity loop with acceleration feed-forwards, with directional scaling and friction compensation.
Data sources. Technical values on this page come from Rockwell publications 1756-TD004 (1756 ControlLogix Integrated Motion Modules Specifications). A single specification document covers the SERCOS and analog motion families, so the numbers on this page can be checked line by line in the manufacturer's table. and the manufacturer's product page for 1756-M02AS. Values re-checked 16 November 2026.