Allen Bradley PLC 1756-SYNCH / 1756SYNCH

China Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier
Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier Allen Bradley PLC 1756-SYNCH / 1756SYNCH supplier

Large Image :  Allen Bradley PLC 1756-SYNCH / 1756SYNCH

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-SYNCH / 1756SYNCH

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1185.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-SYNCH technical data PDF download ControlLogix 1756-SYNCH / 1756SYNCH SynchLink Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-SYNCH (also written 1756SYNCH) is the SynchLink fibre module for the ControlLogix 1756 platform: two fibre-optic ports, 5 Mbps synchronous data rate at 650 nm, a 50 µs frame period, chassis mounted and one slot wide. It coordinates Coordinated System Time across several ControlLogix chassis, moves a small amount of data between them at high speed, and lets one controller consume motion axis data from a controller in another chassis.

A frame carries 3 flags of 3 bytes, a 1-byte control field and a 24-byte data field. Current draw is 1200 mA at 5.1 V DC plus 3 mA at 24 V DC, dissipating 6.2 W and 21.2 BTU/hr. Cabling is 200/230 µm HCS (hard clad silica) fibre terminated with the Versalink V-System, 1…300 m; the temperature code is T4 and operating temperature is 0…60 °C (1756-TD003 Tables 19 and 20).

1756-DHRIODH+ or remote I/O bridge, two selectable ports, 32 connectionsIN STOCK
1756-RIORemote I/O module, scanner or adapter, 32 physical racksIN STOCK
1756-DH485DH-485 network communication moduleIN STOCK
1756-SYNCHSynchLink fibre module, 5 Mbps, 50 us frame, 2 portsIN STOCK

 Application
 SynchLink
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-SYNCH
 Communication
 SynchLink
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 fibre-optic ports, 650 nm, 200/230 um HCS
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-SYNCH product photograph product photograph 1756-SYNCH module product photograph 1756-SYNCH module, second view product photograph

Where the module sits in a typical system

The module is used where two chassis have to share time and motion data: a coordinated drive line split across two ControlLogix racks, or a motion controller that has to consume axis data produced in another chassis. SynchLink carries the Coordinated System Time that makes those axes agree.

The published envelope is small and deliberate — a 24-byte data field in a 50 µs frame at 5 Mbps, over 1…300 m of HCS fibre. It is a time-and-data synchronisation link, not a general-purpose network; I/O and messaging stay on EtherNet/IP or ControlNet.

Commissioning in five steps

  1. Set the link parameters before the module joins the network: DH+ node address and baud rate, remote I/O rack assignment and starting quarter, or the SynchLink node role. A legacy link carries no traffic until these match the existing segment.
  2. Terminate and shield the trunk to the published rules — 1786-RG6 coax for remote I/O, Belden 9463 or equivalent for DH+, 200/230 µm HCS fibre with Versalink V-System connectors for SynchLink.
  3. Insert the module in any 1756 chassis slot; DHRIO and RIO use the standard 1756-A4 through A17 chassis, SYNCH the same range with the PA72/PA75/PB72/PB75/PC75/PH75 supplies.
  4. Add the module to the I/O configuration in Studio 5000 and, for remote I/O, schedule the racks and block transfers before the line is started.
  5. Read the indicators at power-up; on a terminated, addressed segment a dark status indicator is a configuration or wiring fault before it is a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 OK Flashing green Power-up self-test in progress; wait for the solid state.
 OK Off No chassis power at the slot, or the module failed its self-test.
 Link 1 / Link 2 Green solid Fibre link synchronised and the frame is being received.
 Link 1 / Link 2 Flashing green Light detected, synchronisation not established — check the node role and the peer chassis.
 Link 1 / Link 2 Off No light received: fibre polarity, connector contamination, or a break in the run.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.

Replacing a SynchLink link

No successor catalogue number is published for the 1756-SYNCH. Where a design is being rebuilt, synchronisation across chassis is normally carried by EtherNet/IP with the time-synchronisation features of the controller family, and the SynchLink-specific data exchange is re-engineered rather than copied.

For maintenance, the checks that matter are the fibre itself and the node roles: HCS 200/230 µm cable with Versalink V-System termination, runs inside 1…300 m, and one module designated per role in the Studio 5000 project.

Which ControlLogix DH+, remote I/O or SynchLink module to specify

  • 1756-DHRIO — two ports, each selectable between Data Highway Plus and remote I/O. 850 mA at 5.1 V DC. The one module that covers both legacy links.
  • 1756-RIO — one remote I/O port, scanner or adapter, 32 physical racks (0…76). 450 mA at 5.1 V DC.
  • 1756-DH485 — DH-485 network communication for the 1756 chassis.
  • 1756-SYNCH — SynchLink fibre, 5 Mbps at 650 nm, 50 µs frame period, 1200 mA at 5.1 V DC, 1…300 m over 200/230 µm HCS fibre.
  • 1756-EN2T / 1756-EN2TR — the EtherNet/IP destination when a legacy link is being replaced rather than maintained.

FAQ — ControlLogix 1756-SYNCH / 1756SYNCH SynchLink Module

What does the 1756-SYNCH actually synchronise?

Coordinated System Time across ControlLogix chassis. It also moves a limited amount of data between chassis at 5 Mbps and lets one controller consume motion axis data from a controller in another chassis (1756-TD003 Table 19).

What is the data capacity of one frame?

Three flags of 3 bytes, a 1-byte control field and a 24-byte data field, in a 50 µs frame period at 5 Mbps, 650 nm (Table 19). That is the whole published payload — it is a synchronisation link, not a general data network.

What fibre and distance does it support?

200/230 µm HCS (hard clad silica) fibre with Versalink V-System termination, 1…300 m (Table 19). Two fibre-optic ports are on the module; a dark port on a known-good peer is usually polarity or connector contamination.

How much backplane current does it draw?

1200 mA at 5.1 V DC and 3 mA at 24 V DC, dissipating 6.2 W and 21.2 BTU/hr (Table 19). At 1.2 A it is one of the heavier communication modules, so the chassis supply budget is checked before the slot is committed.

What are its environmental limits?

Operating 0…60 °C, storage -40…85 °C, 5…95% RH non-condensing, 2 g vibration at 10…500 Hz, 30 g operating and 50 g non-operating shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF immunity 10 V/m from 80…2000 MHz and 1 V/m from 2000…2700 MHz (Table 20). Temperature code T4.

Which chassis and supplies are approved?

1756-A4, A7, A10, A13 and A17 with the 1756-PA72, PA75, PB72, PB75, PC75 or PH75 supply, in any slot, one slot wide (Table 19).

Which certifications does the module carry?

The module certification list in 1756-TD003 gives c-UL-us UL E65584 and Class I Division 2 UL E194810, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, KC, Morocco and CCC 2020122309111998. Where a classified location is involved, confirm the marking on the module against the panel documentation.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications) and 1756-UM001 (ControlLogix System User Manual) and the manufacturer's product page for 1756-SYNCH. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956