The 1756-RMC10 (also written 1756RMC10) is the long member of the redundancy cable family at 10 m (32.81 ft). It is the published maximum distance between the two redundancy modules of a chassis pair.
It exists for the layout where the two chassis sit in separate cabinets or in different rows of a marshalling area rather than side by side.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Redundancy module connector cable |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-RMC10 |
Length |
10 m (32.81 ft) |
Connector Type |
Dual LC-type (fiber-optic) |
Channels |
2 (transmit and receive fiber) |
Cable Types |
8.5/125 µm singlemode; 62.5/125 µm and 50/125 µm multimode |
Compatible Modules |
1756-RM2, 1756-RM2XT, 1756-RM3, 1756-RM3XT |
Sibling Lengths |
1756-RMC1 (1 m), 1756-RMC3 (3 m) |
Transmission |
1000 Mbps (RM3) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Ten metres is the limit, not a starting point. The family is published as RMC1 (1 m), RMC3 (3 m) and RMC10 (10 m); there is no longer supported length, so a layout that needs 15 m has to be redesigned rather than re-cabled.
The cable is one assembly with two LC connectors carrying transmit and receive. It replaces a two-fiber patch pair, which is why the module has a single dual-LC port rather than two simplex ports.
Fiber type is decided by the transceiver, not the cable alone: 8.5/125 µm singlemode, or 62.5/125 and 50/125 µm multimode are the published types. A long run is normally singlemode with 1783-SFP1GLX or the extended-reach 1GEXE / 1GZX variants.
The pair still has to be two modules of the same catalogue number. A long cable does not compensate for mismatched modules, and the system will not enter redundancy with a mixed pair.
In a two-cabinet layout, the cable is also the part that determines service procedure: pulling a chassis out of the row strains the LC connector, and a strained ferrule reads as a link fault at the partner module.
Nothing is bundled. Transceivers are separate parts, and the RM3-2SFP option ships two 1783-SFP1GLX transceivers but no cable at all.
A redundancy fault is almost always a pairing, fiber or supply problem; the module pair tolerates a failed chassis, not a mismatched cable.
| Indicator | State | Meaning and first action |
| Redundancy module shows a link fault | — | Check the LC connector and the fiber type against the SFP fitted; singlemode and multimode fiber are not interchangeable. |
| Module draws more than expected from the chassis supply | — | 1756-RM2 draws 1.16 A at 5.1 V plus 3.4 mA at 24 V, and 1756-RM3 draws 1 A at 5.1 V plus 5 mA at 1.2 V. |
| Swap of one chassis does not restore redundancy | — | The cable must be re-terminated on the replacement module; a loose LC ferrule reads as a link failure even when the module is healthy. |
Current draw, dissipation, connector and cable data per Rockwell publication 1756-TD001-EN-P and 1756-IN050.
Confirm the run length before ordering; 10 m is the maximum published length.
Choose singlemode fiber with the matching SFP for runs at the top of the range.
Protect the LC connector during chassis service; that connector is the usual failure point.
What is the 1756-RMC10?
A 10 m (32.81 ft) fiber-optic connector cable for ControlLogix redundancy modules.
Is 10 m the maximum?
Yes, it is the longest published length in the RMC family.
What are the shorter options?
1756-RMC1 at 1 m and 1756-RMC3 at 3 m.
What connector does it use?
Dual LC-type fiber connectors.
Which fiber types are accepted?
8.5/125 µm singlemode, 62.5/125 and 50/125 µm multimode.
Are transceivers included?
No, SFPs are ordered separately.
Which modules does it link?
1756-RM2, RM2XT, RM3 and RM3XT pairs.
Does a longer cable change the current draw?
No, the module current is unchanged by cable length.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) - redundancy module current draw, dissipation, chassis and cable data for 1756-RMC10 and the manufacturer's product page for 1756-RMC10. Values re-checked 16 November 2026.