logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-RM / 1756RM

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-RM / 1756RM

China Allen Bradley PLC 1756-RM / 1756RM supplier
Allen Bradley PLC 1756-RM / 1756RM supplier Allen Bradley PLC 1756-RM / 1756RM supplier Allen Bradley PLC 1756-RM / 1756RM supplier Allen Bradley PLC 1756-RM / 1756RM supplier Allen Bradley PLC 1756-RM / 1756RM supplier Allen Bradley PLC 1756-RM / 1756RM supplier

Large Image :  Allen Bradley PLC 1756-RM / 1756RM

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-RM / 1756RM

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2935.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK;
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1756-RM technical data PDF download 1756-RM / 1756RM First-Generation Redundancy Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-RM is the first-generation ControlLogix redundancy module. It links the redundant chassis pair over a single fiber channel and synchronises the two controllers.

It is specified for 0…60 °C and pairs only with another module of the same catalog number, in the same slot of the other chassis.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Redundancy module
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-RM (Series A and Series B)
 Function
 Links the redundant chassis pair and synchronises the two controllers
 Channels
 1 (transmit and receive fiber)
 Connector Type
 LC-PC (fiber-optic)
 Cable Type
 8.5/125 µm single-mode fiber-optic cable
 Wavelength
 1300 nm
 Length, max
 4 km (4000 m)
 Transmission
 100 Mbps or less
 SFP Transceiver
 None - the transceiver is built into the module
 Operating Temperature
 0…60 °C (32…140 °F)
 Backplane Power
 Not published for 1756-RM/A and 1756-RM/B in 1756-UM535
 Partner Module
 Must be the same catalog number, in the same slot of each chassis
 Mixing Rule
 Cannot be mixed with 1756-RM2 or 1756-RM2XT
 Firmware Bundles
 Redundancy bundles 24.052 and later support only 1756-RM2 / RM2XT
 Quantity
 1 per chassis, maximum
 Publication
 1756-UM535 (ControlLogix Redundancy Systems)

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

ControlLogix redundancy module product photograph Redundancy module, second view product photograph Redundancy module, third view product photograph

Where the module sits in the redundant chassis pair

A redundancy pair is not a spare-parts arrangement; it is two modules working as one link. Each redundant chassis carries exactly one redundancy module, in the same slot in both chassis, and the two modules must carry the same catalog number. Rockwell states this as a requirement rather than a recommendation: a partner module with a different number is not supported.

The fiber link is one channel, transmit and receive, over 8.5/125 µm single-mode cable with an LC-PC connector. The published maximum is 4 km at 1300 nm, with the transceiver built into the module rather than supplied as an SFP. That is the practical difference from the RM2 generation, which uses a Rockwell PN-91972 SFP and reaches 10 km with 1000BASE-LX optics.

Speed is where the two generations separate cleanly. The RM/A pair and the RM/B pair each run at up to 100 Mbps, and the pairs must match: RM/A with RM/A, RM/B with RM/B. An RM2 pair runs at 1000 Mbps. The crossload time follows suit, and the formulas are published per module: for RM/A it is DINTs * 0.00091 + 0.6 ms, for RM/B DINTs * 0.00043 + 0.3 ms, and for RM2 DINTs * 0.000550 + 0.39 ms. At 1000 DINTs that is 1.51 ms, 0.73 ms and 0.94 ms respectively — the RM/B pair is actually the fastest of the three, which is why B-series modules still turn up in working plants.

Firmware is the constraint that decides whether this module is usable at all. Redundancy bundles version 24.052 and later support only the 1756-RM2 and 1756-RM2XT. The firmware inside the bundle is written for RM, RM2, RMXT and RM2XT, but the bundle itself will not serve an RM pair beyond that revision. Before purchasing a first-generation module, the installed bundle version decides the answer, not the module's condition.

Mixing is not allowed in either direction. RM2 and RM2XT modules work only with each other, and cannot be paired with RM/A, RM/B or RMXT. A plant that upgrades one chassis and not the other ends up with two modules that cannot talk.

The extended-temperature variant is a separate catalog number, not a rating option on this one. Where the enclosure runs cold, the RMXT is the only member of the first generation that is specified below 0 °C.

Power figures for the RM/A and RM/B are not published in 1756-UM535, so this page does not quote them. The RM2 figure — 1.16 A at 5.1 V DC plus 3.4 mA at 24 V DC — belongs to the RM2 module and is not transferable, in the same way that the RM2's 1000 Mbps and 10 km figures are not.

Commissioning in three checks

  1. Install one module in each chassis of the pair, in the same slot, with the same catalog number.
  2. Fix the firmware bundle before buying the module; bundle 24.052 and later will not run 1756-RM.
  3. Keep both fiber runs physically separated so one event cannot damage channel A and B together.

Indicator and pairing faults

The module has no alphanumeric display; pairing, bundle revision and fiber continuity are the three things a commissioning check must confirm.

 Indicator  State  Meaning and first action
 No indicator on either module  —  Off means no power is applied to the redundancy module, not a lost fiber link.
 Partner mismatch after a module swap  —  A partner module must carry the same catalog number; mixing RM/A with RM/B, or RM with RM2, is not supported.

Facts on this page come only from the Rockwell publications named above; anything they do not state is marked as not published and 1756-IN050.

Replacing this item

Replace with a module of the same catalog number, or plan the whole pair for RM2 at the same time.

Check the firmware bundle revision before ordering; a late bundle cannot run this module.

Keep the slot assignment unchanged so the partner mapping survives the swap.

Which part to specify instead

  • 1756-RM — 100 Mbps pair, 4 km of single-mode fibre, 0…60 °C.
  • 1756-RMXT — the same link with -25…70 °C rating, in an XT chassis.
  • 1756-RM2 — 1000 Mbps and 10 km, required from bundle 24.052 onwards.
  • 1756-RMC1 / RMC3 / RMC10 — the 1 m, 3 m and 10 m fiber-optic cables.

FAQ — 1756-RM / 1756RM First-Generation Redundancy Module

What is the 1756-RM?

The first-generation ControlLogix redundancy module, linking the redundant chassis pair over one fiber channel.

What speed does it run?

Up to 100 Mbps; RM/A pairs with RM/A and RM/B pairs with RM/B.

How far can the fiber run?

4 km on 8.5/125 µm single-mode cable.

Can it be mixed with 1756-RM2?

No, RM2 and RM2XT work only with each other.

Which firmware bundles support it?

Bundles before 24.052; from 24.052 onward only RM2 and RM2XT are supported.

How many modules per chassis?

One, in the same slot in both chassis of the pair.

What does a red indicator mean?

Steady red is the power-up self-test, or a major shutdown fault if it persists.

What is its backplane power draw?

Not published for RM/A and RM/B in 1756-UM535.


Data sources. Technical values on this page come from Rockwell publications 1756-UM535 (ControlLogix Redundancy Systems) - speed, distance, cable, connector, temperature, pairing and firmware bundle rules; 1756-IN087 for the RM2 contrast figures and the manufacturer's product page for 1756-RM. Values re-checked 16 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)