Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IV32 / 1756IV32

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $259.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-IV32 technical data PDF download 1756-IV32 ControlLogix 32 Point Isolated DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IV32 (also written 1756IV32) is the 32-point DC input module with input-to-input isolation: 10...30 V DC, 1.5...5 mA per pin, backplane load 175 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

Isolation is the point of this module: 250 V continuous reinforced inputs-to-backplane plus 250 V basic input-to-input. That is stronger on both axes than the 1756-IV16, which has basic isolation to the backplane and no isolation within a group. Thirty-two points where every channel is separated from every other channel, in one slot.

The per-pin current window, 1.5...5 mA, is half the range of the 16-point IV16. Higher density means a narrower current window per channel, which is the trade for fitting 32 isolated channels in one slot for 175 mA of backplane.

Published details from 1756-IN062: 0...60 °C operating, open-style enclosure, removable terminal block as a separate item, and conductor category 1 routing for field wiring.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IV32
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 32
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IV32 module product photograph 1756-IV32 terminal side product photograph 1756-IV32 module view product photograph

Where the module sits in a typical system

The IV32 is chosen where many channels must be isolated from one another in a compact rack: multi-supplier skids, mixed-earthed circuits, and retrofit panels with little slot space.

Its 1.5...5 mA window suits modern low-current sensors and PLC-to-PLC handshake signals, not legacy devices that draw 10 mA per point.

Because isolation is per channel, screening practice changes: each channel is its own circuit electrically, so the field wiring should be documented per channel rather than per group.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 1.5...5 mA per pin Half the IV16's window. Field devices near 10 mA will not suit this module.
 Check 3 175 mA backplane For 32 isolated points — more per module than an IV16, less per point.
 Check 4 10...30 V DC Same window as the IV16; both stop at 30 V.
 Check 5 Density changes wiring practice Thirty-two isolated pairs on one terminal block; screen and separate them per channel, not per group.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The 16-point equivalent is 1756-IV16, with 1.5...10 mA per pin and group-level isolation.

The standard high-volume 32-point module is 1756-IB32: 5.5 mA per input, 120 mA backplane, group isolation.

The high-voltage isolated module is 1756-IH16I for 90...146 V DC circuits.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IV32 ControlLogix 32 Point Isolated DC Input | Rockwell

What is the 1756-IV32?

A 32-point DC input module, 10...30 V DC, 1.5...5 mA per pin, with input-to-input isolation.

What is the backplane current?

175 mA at 5.1 V DC and 2 mA at 24 V DC.

What isolation does it provide?

250 V continuous reinforced inputs-to-backplane and 250 V basic input-to-input.

How does it compare with the 1756-IV16?

Twice the points, half the per-pin current window, reinforced backplane isolation and input-to-input isolation instead of group isolation.

How does it compare with the 1756-IB32?

The IB32 is the volume module with group isolation at 120 mA backplane; the IV32 adds per-channel isolation at 175 mA.

What is the input voltage range?

10...30 V DC.

Is a terminal block included?

No — the removable terminal block is a separate item.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IV32. Values re-checked 15 November 2026.


Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)