logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IV16 / 1756IV16

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IV16 / 1756IV16

China Allen Bradley PLC 1756-IV16 / 1756IV16 supplier
Allen Bradley PLC 1756-IV16 / 1756IV16 supplier Allen Bradley PLC 1756-IV16 / 1756IV16 supplier Allen Bradley PLC 1756-IV16 / 1756IV16 supplier Allen Bradley PLC 1756-IV16 / 1756IV16 supplier Allen Bradley PLC 1756-IV16 / 1756IV16 supplier Allen Bradley PLC 1756-IV16 / 1756IV16 supplier

Large Image :  Allen Bradley PLC 1756-IV16 / 1756IV16

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IV16 / 1756IV16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $195.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IV16 technical data PDF download 1756-IV16 ControlLogix 16 Point 10-30V DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IV16 (also written 1756IV16) is the 16-point DC input module with a published input current range of 1.5...10 mA per pin at 10...30 V DC, and a backplane load of 110 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

That per-pin range is unusual and worth reading twice. Most 24 V input modules publish a single maximum input current; this one publishes a window, which tells you the module's threshold behaviour varies with the applied voltage rather than being a fixed 24 V load. It is the same class of detail that separates a real specification from a marketing line.

Isolation is 250 V continuous basic from inputs to backplane and 250 V basic input group-to-group, with no isolation between individual inputs within a group. The 1756-IV32, the 32-point relative, takes the next step: reinforced to the backplane and 250 V basic input-to-input.

The module uses the 20-pin NEMA screw-clamp removable terminal block (1756-TBNH), rated at 1.36 N·m (12 lb-in) per the 1756-IN062 terminal block table — the same block class as the 1756-IB16.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IV16
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IV16 module product photograph 1756-IV16 terminal side product photograph 1756-IV16 module view product photograph

Where the module sits in a typical system

The IV16 covers general 24 V DC field signals where a 30 V ceiling is acceptable — the practical difference from the IB16's 31.2 V is small, but it is published, so it belongs in the design record.

Its 1.5...10 mA input window makes it a candidate for mixed field devices: sensors that draw little current still register, and devices that draw more are inside the range.

Where circuits must be separated from one another, the 1756-IV32 gives input-to-input isolation at 175 mA backplane for 32 points.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Group isolation only  250 V between groups, none inside a group. Use the IV32 where per-input isolation is needed.
 Check 3  110 mA backplane  Slightly above the standard IB16, and well below the diagnostic and ISOE variants.
 Check 4  20-pin terminal block  1756-TBNH screw-clamp, 1.36 N·m — ordered separately.
 Check 5  10...30 V DC  The narrower window, not the 31.2 V of the IB16.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The 32-point equivalent with input-to-input isolation is 1756-IV32.

The standard 24 V module with a 31.2 V ceiling and reinforced backplane isolation is 1756-IB16.

For 90...146 V DC circuits the module is 1756-IH16I.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IV16 ControlLogix 16 Point 10-30V DC Input | Rockwell

What is the 1756-IV16?

A 16-point DC input module, 10...30 V DC, with a published input current of 1.5...10 mA per pin.

What is the backplane current?

110 mA at 5.1 V DC and 2 mA at 24 V DC.

Why does it publish a current range?

The input current the module presents depends on the applied voltage; the published window is 1.5...10 mA per pin.

What isolation does it provide?

250 V continuous basic inputs-to-backplane and 250 V basic input group-to-group, with no isolation between individual inputs in a group.

Which terminal block does it use?

The 20-pin NEMA screw-clamp block 1756-TBNH, torqued to 1.36 N·m (12 lb-in).

What is the input voltage range?

10...30 V DC.

Is there a 32-point version?

Yes — 1756-IV32, with 1.5...5 mA per pin and input-to-input isolation.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IV16. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)