logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IM16I / 1756IM16I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IM16I / 1756IM16I

China Allen Bradley PLC 1756-IM16I / 1756IM16I supplier
Allen Bradley PLC 1756-IM16I / 1756IM16I supplier Allen Bradley PLC 1756-IM16I / 1756IM16I supplier Allen Bradley PLC 1756-IM16I / 1756IM16I supplier Allen Bradley PLC 1756-IM16I / 1756IM16I supplier Allen Bradley PLC 1756-IM16I / 1756IM16I supplier Allen Bradley PLC 1756-IM16I / 1756IM16I supplier

Large Image :  Allen Bradley PLC 1756-IM16I / 1756IM16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IM16I / 1756IM16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $327.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IM16I technical data PDF download 1756-IM16I ControlLogix 16 Point Isolated 240V AC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IM16I (also written 1756IM16I) is the 240 V AC input module: 240 V AC at 50/60 Hz, 13 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC, isolation 250 V continuous basic inputs to backplane and input to input (1756-IN064).

It is the only 240 V AC input in the published table. Every other AC input module in the family is a 120 V or low-voltage part, so a panel with 240 V pilot circuits — European machine feeds, 240 V control circuits, direct 240 V limit and pressure switches — lands here without an interposing relay.

The isolation pair is 250 V to the backplane and 250 V input to input, which is the arrangement the voltage demands and the opposite of the IA16I's 125 V. Each input has its own barrier at the full 250 V, so separate 240 V circuits can share the module without a common reference.

Its temperature code is T4 rather than the T4A published on the 120 V inputs — 135 °C maximum surface temperature against 120 °C — and its backplane draw at 24 V DC is 3 mA, the same as the IA16I. Both figures come from the same installation instructions table.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IM16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IM16I module product photograph 1756-IM16I label product photograph 1756-IM16I terminal side product photograph

Where the module sits in a typical system

Use it where the machine's control voltage is 240 V AC and the signals must be read directly: limit switches on a 240 V feed, pressure and temperature switches, and the status contacts of 240 V contactors.

The 250 V input-to-input isolation is what allows several 240 V circuits on one card. Two separate 240 V feeds, one per machine section, can be terminated on the same module with their own barriers intact.

Where a 240 V circuit only needs a status bit in the controller and an interposing relay already exists, the 120 V IA16 on the relay's auxiliary contact is the cheaper arrangement; the IM16I is for direct 240 V sensing.

Commissioning in five steps

  1. Check the module's published input current against the field device's leakage. A 120 V AC input at 13 mA will hold off a two-wire sensor that leaks a few milliamps; a low-current module will not. Input current is an immunity figure, not a burden.
  2. Decide the common arrangement before wiring, because the isolation table is per module and not per family. The IA16 has two groups of eight with 125 V between them, the IA8D has no isolation between its inputs at all, and the IA16I isolates every point — but only at 125 V.
  3. Confirm the nominal voltage against the published window, not against the panel label. The IA32 accepts 74...132 V AC, so it works on a 110 V nominal supply with deep brownout; a 240 V circuit needs the IM16I.
  4. Respect 60 °C as the surrounding-air limit and mount the module in a slot where the chassis airflow is unobstructed; every rating in 1756-IN064 is quoted at that ambient.
  5. Terminate on the 1756-TBNH or 1756-TBSH removable terminal block with 0.33...2.1 mm² (22...14 AWG) wire rated 90 °C or better, and 1.2 mm maximum insulation.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  250 V input to input  Not 125 V. Each point carries its own 250 V barrier, so different 240 V circuits can coexist on one module.
 Check 3  T4, not T4A  135 °C maximum surface temperature under the North American classification — a less restrictive code than the 120 V modules carry.
 Check 4  13 mA per point  Enough current to hold off leakage on a 240 V run, where capacitive coupling from long cable is stronger than at 120 V.
 Check 5  20 mA... check the field device  A 240 V input draws 13 mA at 240 V; confirm a series device such as a neon indicator or a timer relay tolerates that burden.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC input module of an earlier generation

For 120 V AC signals with individual isolation, use 1756-IA16I.

For 32 points on a 74...132 V AC window, use 1756-IA32.

For low-voltage AC input from a 10...30 V AC source, use 1756-IN16 at 25 mA maximum.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IA16 — 16 inputs at 120 V AC, 13 mA per point, two groups of eight with 125 V group-to-group isolation.
  • 1756-IA16I — 16 inputs individually isolated from each other, 120 V AC at 15 mA.
  • 1756-IA32 — 32 inputs in one slot, 74...132 V AC at 15 mA, the widest input window in the family.
  • 1756-IA8D — 8 inputs at 120 V AC with the highest input current, 16 mA per point.
  • 1756-IM16I — 16 isolated inputs at 240 V AC, the only 240 V AC input module published.
  • 1756-IN16 — 16 inputs at 10...30 V AC, 25 mA maximum per point.

FAQ — 1756-IM16I ControlLogix 16 Point Isolated 240V AC Input | Rockwell

What is the 1756-IM16I?

A 16-point 240 V AC input module with input-to-input isolation, 13 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC.

What input voltage does it accept?

240 V AC at 50/60 Hz, as published in 1756-IN064.

Is it the only 240 V AC input module?

Yes in this published table — the IA8D, IA16, IA16I, IA32 and IN16 are 120 V or low-voltage parts.

How is it isolated?

250 V continuous basic, both inputs to backplane and input to input.

What is its temperature code?

T4, which is 135 °C maximum surface temperature — the 120 V modules are T4A at 120 °C.

How much current does each input draw?

13 mA at 240 V AC.

Can I put two separate 240 V feeds on one module?

Yes. Each input has its own 250 V barrier, so the circuits do not need a shared reference.

What is the maximum surrounding air temperature?

60 °C.

Which document publishes these ratings?

1756-IN064, the installation instructions for the ControlLogix AC digital I/O modules.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IM16I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)