The 1756-IM16I (also written 1756IM16I) is the 240 V AC input module: 240 V AC at 50/60 Hz, 13 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC, isolation 250 V continuous basic inputs to backplane and input to input (1756-IN064).
It is the only 240 V AC input in the published table. Every other AC input module in the family is a 120 V or low-voltage part, so a panel with 240 V pilot circuits — European machine feeds, 240 V control circuits, direct 240 V limit and pressure switches — lands here without an interposing relay.
The isolation pair is 250 V to the backplane and 250 V input to input, which is the arrangement the voltage demands and the opposite of the IA16I's 125 V. Each input has its own barrier at the full 250 V, so separate 240 V circuits can share the module without a common reference.
Its temperature code is T4 rather than the T4A published on the 120 V inputs — 135 °C maximum surface temperature against 120 °C — and its backplane draw at 24 V DC is 3 mA, the same as the IA16I. Both figures come from the same installation instructions table.
1756-IB16 |
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 |
In stock |
1756-IB16D |
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA |
In stock |
1756-IB16I |
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA |
In stock |
1756-IB16IF |
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA |
In stock |
1756-IB16ISOE |
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA |
In stock |
1756-IB32 |
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 |
In stock |
1756-IC16 |
16 inputs, 30...60 V DC, backplane per 1756-IN062 |
In stock |
1756-IG16 |
16 TTL inputs, backplane per 1756-IN062 |
In stock |
1756-IV16 |
16 inputs, 48 V DC, backplane per 1756-IN062 |
In stock |
Application |
Discrete input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IM16I |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Digital Input Module |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Use it where the machine's control voltage is 240 V AC and the signals must be read directly: limit switches on a 240 V feed, pressure and temperature switches, and the status contacts of 240 V contactors.
The 250 V input-to-input isolation is what allows several 240 V circuits on one card. Two separate 240 V feeds, one per machine section, can be terminated on the same module with their own barriers intact.
Where a 240 V circuit only needs a status bit in the controller and an interposing relay already exists, the 120 V IA16 on the relay's auxiliary contact is the cheaper arrangement; the IM16I is for direct 240 V sensing.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 250 V input to input | Not 125 V. Each point carries its own 250 V barrier, so different 240 V circuits can coexist on one module. |
| Check 3 | T4, not T4A | 135 °C maximum surface temperature under the North American classification — a less restrictive code than the 120 V modules carry. |
| Check 4 | 13 mA per point | Enough current to hold off leakage on a 240 V run, where capacitive coupling from long cable is stronger than at 120 V. |
| Check 5 | 20 mA... check the field device | A 240 V input draws 13 mA at 240 V; confirm a series device such as a neon indicator or a timer relay tolerates that burden. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
For 120 V AC signals with individual isolation, use 1756-IA16I.
For 32 points on a 74...132 V AC window, use 1756-IA32.
For low-voltage AC input from a 10...30 V AC source, use 1756-IN16 at 25 mA maximum.
What is the 1756-IM16I?
A 16-point 240 V AC input module with input-to-input isolation, 13 mA per point, backplane 100 mA at 5.1 V DC and 3 mA at 24 V DC.
What input voltage does it accept?
240 V AC at 50/60 Hz, as published in 1756-IN064.
Is it the only 240 V AC input module?
Yes in this published table — the IA8D, IA16, IA16I, IA32 and IN16 are 120 V or low-voltage parts.
How is it isolated?
250 V continuous basic, both inputs to backplane and input to input.
What is its temperature code?
T4, which is 135 °C maximum surface temperature — the 120 V modules are T4A at 120 °C.
How much current does each input draw?
13 mA at 240 V AC.
Can I put two separate 240 V feeds on one module?
Yes. Each input has its own 250 V barrier, so the circuits do not need a shared reference.
What is the maximum surrounding air temperature?
60 °C.
Which document publishes these ratings?
1756-IN064, the installation instructions for the ControlLogix AC digital I/O modules.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IM16I. Values re-checked 15 November 2026.